Fluke T6-600 Part 3, VFD Drives and Other Waveform Testing

Поділитися
Вставка
  • Опубліковано 23 жов 2024

КОМЕНТАРІ • 34

  • @1pcfred
    @1pcfred 6 років тому +7

    Official Fluke cork accessory is a must have.

    • @Universal_Craftsman
      @Universal_Craftsman Рік тому +3

      He had an aftermarket one, original Fluke cork with Cat IV rating is probably 200$. 😄

  • @joshpeck2697
    @joshpeck2697 4 роки тому +2

    Thanks a lot for your time and effort. Bought that tester last month ,one thing for sure that field senser is not safe at all was testing hot wires in fast sequence around 9th was getting indication not energised . Bye the way perfect presentation. We all should buy you new tester .thanks a lot Merry Christmas and Happy new year

    • @joesmith-je3tq
      @joesmith-je3tq  4 роки тому +1

      I spent the time looking over the patents I could find on the technology. It is pretty interesting but as we have seen, it needs work. I doubt electricians would use it to prove if a circuit is live or not, but again I am not big on safety and assume people working in hazardous environments have proper education, training, license .... If you watched the ave videos, obviously it is not fool proof.

    • @scabthecat
      @scabthecat 3 роки тому

      @@joesmith-je3tq Certainly don't use it to prove dead

    • @joesmith-je3tq
      @joesmith-je3tq  3 роки тому

      @@scabthecat I doubt any electrician would.

  • @jamessouth4776
    @jamessouth4776 6 років тому +1

    Nice video Joe,very interesting, seems like one of those is kinda an initial test to get some rough measurements on some equipment before you would grab a normal industrial multimeter, I think still would double check its readings!

    • @joesmith-je3tq
      @joesmith-je3tq  6 років тому +1

      I guess if you knew ahead that the T6 was compatible with the waveform you wanted to measure you would be fine. In general, from the limited tests I have ran, it would be fine in many cases but it's not good enough.

  • @felixcat4346
    @felixcat4346 6 років тому +2

    Thanks for doing all these tests. It would be very educational if you could try doing robustness tests on a few automotive battery operated oscilloscopes.

    • @joesmith-je3tq
      @joesmith-je3tq  6 років тому +3

      I can't imagine taking a $4000 Fluke scope to task. Like any scope, I doubt their front ends are designed to survive transients like these. This is why I use various high voltage probes with the the scopes. I did test a low end 100X probe once which is why I started to make my own. The scopes cost too much to put them at risk with a poor quality probe.

  • @NiHaoMike64
    @NiHaoMike64 6 років тому +1

    Could it be that it reacts adversely to frequencies higher than what the VFD puts out? Perhaps it's worth trying to use the noncontact feature within a foot or so of an operating ignition system? Could be a real problem for HVAC techs who regularly deal with modern gas furnaces.

  • @mattperttula5210
    @mattperttula5210 3 роки тому

    I've been playing around with my fluke T6 and an oscilloscope. If you connect the ground of the scope to the negative test lead and hold tip of the scope probe in the fork with Field Sense active, the device emits a 2.4kHz sine wave that the scope can pick up. You actually don't need to ground the scope to the meter to see this, that is just when I got the best signal. As soon as you turn off the field sense function the 2.4kHz waveform disappears. If you look at the waveform that the meter couldn't read around 8:26 and count the peaks there are 26 peaks in 1/4 cycle so the frequency of the waveform superimposed on the 60Hz sine wave is 60*26*2 = 3.120kHz which is pretty close to 2.4kHz. Without fully understanding what they are doing on the inside, it appears that they are modulating the Field Sense measurement on a 2.4kHz carrier frequency. My guess is that if the signal you are measuring has too much frequency content in the vicinity of 2.4kHz the meter can't deal with it properly. it would be interesting to see the frequency spectrum for the wave forms that fail to produce a reading. Thanks for the informative video!

    • @joesmith-je3tq
      @joesmith-je3tq  3 роки тому

      You may be interested in the following: www.eevblog.com/forum/testgear/fluke-fieldsense-contactless-voltmeter/

    • @mattperttula5210
      @mattperttula5210 3 роки тому

      @@joesmith-je3tq Thanks, I'll check that out. Really enjoy the videos, super useful information.

  • @MK-sy5lp
    @MK-sy5lp Рік тому

    Hi joe
    Sorry very late to the party with a comment 😂.
    Thank you for yr awesome videos highly appreciated
    Would love to see how all yr meters read that output voltage from the drive
    Tested my 867s brymen it reads about 6v higher than my fluke 87v on a small drive with frequency of about 1.5khz
    Regards

    • @joesmith-je3tq
      @joesmith-je3tq  Рік тому

      What's the 3dB rolloff for your Fluke vs Brymen?

    • @MK-sy5lp
      @MK-sy5lp Рік тому

      @joesmith-je3tq to be very honest I have no clue
      Not very technical when it comes to that

  • @wktodd
    @wktodd 6 років тому

    Nice one Joe:-) Looks like the meter is safe enough except for the false negative on spiked waveforms. I didn't catch, on the first viewing, whether the meter differentiated between no volts and no read, is it obvious that it is not reading rather than no signal?

    • @joesmith-je3tq
      @joesmith-je3tq  6 років тому +2

      The way it works, you can wrap the black lead through the clamp and the lack of ground indicator will turn off. So they will show you when the circuit is complete. When the meter is not connected, you will see lack of ground active and three dashes. If you watch the video, often you will see the three dashes with the ground indicator off. Again, the same case as just testing with the black lead in the clamp.

  • @hi-friaudioman
    @hi-friaudioman 6 років тому +1

    Man, those were some funky waveforms!

  • @MalagasOnFire
    @MalagasOnFire 6 років тому

    We have in PT a lot of cork. Well the clamp doesn't like much noise / glitches on the sinewave and i think in the part 2 there was a refered 2.4KHz frequency carrier on the clamp and in part 3 the final pure sinewave was tested at 2.399ish KHz, which is very near and would trip the meter and does not read even at 10% of the value. On the other hand if the device is not reading properly we could also suspect the line by its behavior... Very nice test JIG and wave form generation. What about doing a reading between two Power Line Ethernet points , will it trip either?

    • @joesmith-je3tq
      @joesmith-je3tq  6 років тому

      Are you asking about those adapters that allow Ethernet over AC lines?

    • @MalagasOnFire
      @MalagasOnFire 6 років тому

      Yes, that kind of adapters

    • @joesmith-je3tq
      @joesmith-je3tq  6 років тому

      I assume you are required to have a licensed electrician install these which is why you are asking. I am not understanding your question "will it trip either?" Ethernet should be isolated and I doubt they have two of these sitting next to one another. So I am not sure how you are proposing you would connect the T6. Could you just post a quick sketch and post it on the EEVBLOG site? This may help.

    • @MalagasOnFire
      @MalagasOnFire 6 років тому

      My question is if the T6 clamp meter will stop reading voltage of one of the AC terminals in between these power line ethernet that you plug on the wall socket one end and then another, assuming that it introduces some sort of high frequency signal on the AC line between the two power ethernet's .
      Here is the sketch : photos.app.goo.gl/B0qr0wkNsptsawkN2

    • @joesmith-je3tq
      @joesmith-je3tq  6 років тому

      We already know there are cases where the meter will not detect voltage. I don't own any of these adapters but you may want to try some of the other reviewers. Perhaps they are using these.

  • @RGSABloke
    @RGSABloke 6 років тому

    Awesome video sir, I hope AvE had a look at this too! He also had concerns about it. I am not sure this meter is directed at, seems to me the marketing wanks have been given free hand here. I would jut get the 381 it works just fine. kindest regards JOE

  • @MarcusMussawar
    @MarcusMussawar 4 роки тому

    when would you see waveforms with the small spike in the field? what is something that could cause those ?

    • @joesmith-je3tq
      @joesmith-je3tq  4 роки тому

      I am not sure what you consider a small spike. The act of sitting in a chair can create small spikes which I am sure is not what you are asking. I suggest doing some searching using Google for "AC mains transients cause" or what ever it is that you are looking for information on. It works wonders.

    • @joesmith-je3tq
      @joesmith-je3tq  4 роки тому

      Wiki even has a page for you: en.wikipedia.org/wiki/Voltage_spike

    • @MarcusMussawar
      @MarcusMussawar 4 роки тому

      @@joesmith-je3tq thank you and thank you for the video amazing work a bit concerning seeing how easy it is to cause the meter not to read

    • @joesmith-je3tq
      @joesmith-je3tq  4 роки тому

      @@MarcusMussawar That's the problem I see with it. I like the concept and did some patent searches on people have done it. Maybe someone will get the technology to be a little more forgiving than this one is.

  • @mikeadler434
    @mikeadler434 9 місяців тому

    👍👍

  • @dosgos
    @dosgos 6 років тому +1

    Self-testing!