[Best buy Affiliate links] JK BMS, Lifepo4 Cells & Active Balancer enigmapowers.com/?ref=ZenInnovations Buy UTL Gamma Plus 3350 With Lithium Support amzn.to/49GAmbc Buy UTL Gamma plus 2kVA 24v amzn.to/3Q723S2 Buy UTL Gamma Plus 1kva amzn.to/3xodWtz Sigma 313A With Inrush amzn.to/46Q5KTr Setup Tour ua-cam.com/video/_KDDVLtq3Pk/v-deo.html How to connect Multiple parallel batteries on 12v Solar inverter ua-cam.com/video/82WY-aM7PvY/v-deo.html Chapters Hindi 00:00 Inaccurate display problems with Old Gamma 2020 models 01:23 SPV solar Ampere test 02:35 Battery charging Amps 03:57 Output AC voltage (Backup volts) 05:22 Solar Panel Voltage (SPV volts) 06:14 Battery voltage Test (Accurate enough for lithium?) #UTLGammaPlus #UTLGammaplus3350 #SolarEnergy #SolarPCU #solarinverter #ZenHindi #ZenInnovations #saveenergy
I am personally using a 150Ah 25.6V LFP battery and Gamma+ 3350 in my home. The problem with this inverter is that the Grid Changeover is set at 90% SOC of the battery. Which means in PCU mode, you utilize 90% battery before switching to the grid. There is no option given to change that parameter in Lithium Mode. Either you have to use PCU mode and run the inverter 24x7, or you have to use smart mode to use the solar from Sunrise to Sunset. My best advice is, get a high capacity LFP battery if you are planning on using PCU mode and go complete off-grid, or get a small capacity, say 50Ah 25.6V which gives you 1280Wh, and run the inverter at Smart mode and utilize the solar power during day time, and keep the rest of the battery as standby for power cuts in the night. The only way UTL can fix this is by using Smart Shunt to calculate based on Wh instead of voltage. Since LFP batteries cannot be accurately mesaured based on Voltage. One more tip, setting the LFP charging voltage at 13.6V / 27.2V is best for its life, and to quickly switchover to Solar in Smart mode.
I just bought this UTL 3350 Gamma+. Want to know all the features and how it’s actually works. Kindly make a video on this & if you already made a video on this please share such link
Sir kya isi inverter ka reading ka meaning and settings kaise kare iska ek vedio bana denge..matlab boost charge kaise kare kab kare mains pe kare ya solar se v hoga..or kya kya settings karna hota hai agar ek vedio bana dete to bohot help hota sirji..
I too have UTL inverter 2kva 2600 model, please make a video on advanced setting for 24v battery system. Searched everywhere but couldn't find any video related to this.
Lga sakte hain bhai Qki solar apni max Power Kabhi Nahi dete hain 2300 watt hota hain 575×4=2300 esse jyada watt mat lgana bhai or DCDB Box Jarur Lgana
UTL ME CALIBRATION KAR KE LITHIUM BATTERY CHARGE NAHI HO RAHI HAI FLAT VOLT PE RHEGA TABHI SOLAR OR MAINS KO KAT KAR FIR BATTERY KA VOLT CHECK KIJIYE PATA CHAL JAYEGA
Sir i am confused between samsung windfree 1.5 ton 5 star and lg virat 1.5 ton 5 star.. My main concern is electricity consumption.. So which is best for low electricity consumption?.. Please reply sir..
भाई जी, यदि ठंड के मौसम में घर के इन्वर्टर में बैटरी सलेक्शन मोड को ट्यूबलर की जगह flat plate में रखा जाय और चार्जिंग को slow में रखा जाय तो पुरानी बैटरी को कोई फायदा मिलेगा? मैं कानपुर का रहने वाला हूं, गर्मी और ठंड दोनों अपने अपने मौसम में खूब पड़ती है। घर में प्योर साइनवेव इन्वर्टर पर तीन साल पुरानी एक 150ah की tall tubular बैटरी लगी है।
Hello Sir. I have an electric Geyser of 1500 watts. Can I give it DC current by two 550 watts in series? I need just light warm water. In winter I want to use spare power in this way. Wouldn't this be harmful to the solar panels, because it might be like a short circuit.? Regards.
@@ZenInnovations experimentally, I gave output of one 545 Longi panel to an immersion rod 2000 watts into a mug of water. In 10 minutes water got very little warmth as compared to tap water. Safer side, I inserter a DC breaker which didn't trip. In my next experiment, I will use a 12 volts coffee rod used in car. I will let you know. A DC Breaker is a good idea to avoid any unpleasant result.
@@O.A.Level.Mathematics excellent. Keep learning. Rather than dc breaker, use a car Headlight bulb in series with the rod. Which limits current and works as ballast.
@@ZenInnovations Battery capacity digital meter might be a good idea? Else, we should set cutoff voltage, say 11.5 volts for a good remaining charge to avoid deep discharge.
I am using UTL gama 1000va 24volt MPPT fan stop working when I register complain against this issue, mechanic came and put some lubrication oil and said it's ok now, I request to change the fan but they didn't change , after some time it's happen again again I made complain again same done by service mechanic. Service is not good of UTL
Bhai maine 550 watt ke 4 panel parallel mai install karaye jisme single panel ki voc aur amp hai 48v and 14 amp ..... Aab mera inverter 48 v toh show kar raha hai lekin current 16 amp show kar raha hai jabki parallel mai current add hota hai toh uss hisab se 4 panel ka current 56 ampere hua ...... maine clamp meter bhi laga ke dekha woh bhi 16 ampere show kar raha hai .... Aisa kyu bhai mere panel ki power waste kyu ho rahi hai mujhe poora 48 volt aur 56 amp kyu nahi mil raha 😢🥺☹️ plz help
[Best buy Affiliate links]
JK BMS, Lifepo4 Cells & Active Balancer
enigmapowers.com/?ref=ZenInnovations
Buy UTL Gamma Plus 3350 With Lithium Support amzn.to/49GAmbc
Buy UTL Gamma plus 2kVA 24v amzn.to/3Q723S2
Buy UTL Gamma Plus 1kva amzn.to/3xodWtz
Sigma 313A With Inrush amzn.to/46Q5KTr
Setup Tour ua-cam.com/video/_KDDVLtq3Pk/v-deo.html
How to connect Multiple parallel batteries on 12v Solar inverter ua-cam.com/video/82WY-aM7PvY/v-deo.html
Chapters Hindi
00:00 Inaccurate display problems with Old Gamma 2020 models
01:23 SPV solar Ampere test
02:35 Battery charging Amps
03:57 Output AC voltage (Backup volts)
05:22 Solar Panel Voltage (SPV volts)
06:14 Battery voltage Test (Accurate enough for lithium?)
#UTLGammaPlus #UTLGammaplus3350 #SolarEnergy #SolarPCU #solarinverter #ZenHindi #ZenInnovations #saveenergy
Great accuracy testing as compared to old utl gamma plus pcu 👌👌🔥🔥
Thanks!
Only defect is that it Supports 2100 Watt Panel . It would be greater if it supports 3000 Watt Panel👍
Sir apki lithium battery kesi chal ragi and kis inverter pr laga rakhi hai..aap use nai krte..
Sir app isme Solar battery use kar rahe ya normal inverter battery.. appka new battery dikh ra video me
Sir is inverter me 150ah ki 4battery laga saktahu kya? 2 .2 karke pera lalme?
Sir aapne solar panel without DCDB use karte ho kya please inspe ek video banao😊
Ok
Thanks Bhai aapne etne achhe se hume samjha diya😊
Welcome.
I am personally using a 150Ah 25.6V LFP battery and Gamma+ 3350 in my home.
The problem with this inverter is that the Grid Changeover is set at 90% SOC of the battery. Which means in PCU mode, you utilize 90% battery before switching to the grid. There is no option given to change that parameter in Lithium Mode.
Either you have to use PCU mode and run the inverter 24x7, or you have to use smart mode to use the solar from Sunrise to Sunset.
My best advice is, get a high capacity LFP battery if you are planning on using PCU mode and go complete off-grid, or get a small capacity, say 50Ah 25.6V which gives you 1280Wh, and run the inverter at Smart mode and utilize the solar power during day time, and keep the rest of the battery as standby for power cuts in the night.
The only way UTL can fix this is by using Smart Shunt to calculate based on Wh instead of voltage. Since LFP batteries cannot be accurately mesaured based on Voltage.
One more tip, setting the LFP charging voltage at 13.6V / 27.2V is best for its life, and to quickly switchover to Solar in Smart mode.
Good discussion.
I just bought this UTL 3350 Gamma+.
Want to know all the features and how it’s actually works.
Kindly make a video on this & if you already made a video on this please share such link
There are many videos in my solar energy Playlist. Pls check description
Sir kya isi inverter ka reading ka meaning and settings kaise kare iska ek vedio bana denge..matlab boost charge kaise kare kab kare mains pe kare ya solar se v hoga..or kya kya settings karna hota hai agar ek vedio bana dete to bohot help hota sirji..
Sure..
I too have UTL inverter 2kva 2600 model, please make a video on advanced setting for 24v battery system. Searched everywhere but couldn't find any video related to this.
Sure.
make video about anvanced calibration and open it for looks inside transformaer
Utl Gama plus 3350 how many solar panels are connected what is the wire size and is DCDB used for it make DCDB wiring video please 😊
Iski load test ki video bnayi ki kitne ampere or watt load le skta h ye
Thanks sir for your testing video 👌👌👌this type of video we can expect from this channel . Your efforts is great. Thanks 🙏🙏
So nice of you
Sir ispe topcon baifceal 575 watt ke 4 panel lga skte h kye ? Plz reply
Lga sakte hain bhai Qki solar apni max Power Kabhi Nahi dete hain 2300 watt hota hain 575×4=2300 esse jyada watt mat lgana bhai or DCDB Box Jarur Lgana
Much waited review
Cool
Sir mera me battery voltage 14.6 tak ja ra hai
Sir battery 🔋 ka voltage 28.6 voltage is set in my 224 Gama solar pcu is this any problem ?
ua-cam.com/video/1RMkdRQ1vg4/v-deo.html
UTL ME CALIBRATION KAR KE LITHIUM BATTERY CHARGE NAHI HO RAHI HAI
FLAT VOLT PE RHEGA TABHI SOLAR OR MAINS KO KAT KAR FIR BATTERY KA VOLT CHECK KIJIYE PATA CHAL JAYEGA
Utl solar heliac model hai
Charging nehi ho raha hai
Ac main kya kharab ho sakta hai
Sir i am confused between samsung windfree 1.5 ton 5 star and lg virat 1.5 ton 5 star..
My main concern is electricity consumption..
So which is best for low electricity consumption?..
Please reply sir..
No doubt,
VIRAAT 1.5 Ton 5 Star AI+ DUAL Inverter Wi-Fi 2023
Amazon RS-Q20GWZE Gold strip amzn.to/3q44XOh
Amazon RS-Q20HWZE (white) amzn.to/3Q9hlHE
Flipkart ekaro.in/enkr20230721s30160513
भाई जी, यदि ठंड के मौसम में घर के इन्वर्टर में बैटरी सलेक्शन मोड को ट्यूबलर की जगह flat plate में रखा जाय और चार्जिंग को slow में रखा जाय तो पुरानी बैटरी को कोई फायदा मिलेगा?
मैं कानपुर का रहने वाला हूं, गर्मी और ठंड दोनों अपने अपने मौसम में खूब पड़ती है। घर में प्योर साइनवेव इन्वर्टर पर तीन साल पुरानी एक 150ah की tall tubular बैटरी लगी है।
Jyada fayda nahi hoga. Just keep correct settings as explained here-
ua-cam.com/video/1RMkdRQ1vg4/v-deo.html
Sir kya ye load solar or battary ka mix kark utha sakta he
Yes.
How many amperes are required to charge a 24 volt battery? Lead acid. Nafiz form Bangladesh 🇧🇩
ua-cam.com/video/1RMkdRQ1vg4/v-deo.html
As usual, good one.
Thanks.
Sir make a video off lithium battery backup sir pls
ok
Settings batayiye
Hello Sir.
I have an electric Geyser of 1500 watts. Can I give it DC current by two 550 watts in series? I need just light warm water. In winter I want to use spare power in this way.
Wouldn't this be harmful to the solar panels, because it might be like a short circuit.?
Regards.
Panels wouldn't mind much, but I doubt it'll provide any decent effect. Report back if you try.
@@ZenInnovations experimentally, I gave output of one 545 Longi panel to an immersion rod 2000 watts into a mug of water. In 10 minutes water got very little warmth as compared to tap water. Safer side, I inserter a DC breaker which didn't trip. In my next experiment, I will use a 12 volts coffee rod used in car. I will let you know. A DC Breaker is a good idea to avoid any unpleasant result.
@@O.A.Level.Mathematics excellent. Keep learning. Rather than dc breaker, use a car Headlight bulb in series with the rod. Which limits current and works as ballast.
Good work Gama plus, nice video ❤
Thanks 😁
Saregama plus per AC Run kara ke dikhaiye
Definitely
Thanks 👍 bhadu mama
your utla 3kva video efficiency test video is getting too late bro ! please post it as soon as possible
Coming soon, Stay subscribed!
Kitan maximum Ac ampere load le skta hai
Subscribe for test.
I am using utl gamma 3350 540*4 panel utl battery 165*2 ah back time 3-4hrs only on 11% load please help me with any settings
Contact service center
how much time you need to upload the inside looks video and DC to AC efficiency test video?
Rs kitna hai sir please reply
Check description
Good information 👍
Thanks
Super bhai
Thanks.
👍👍😎
Thank you
Best test
Thank you
Prise?
Check description
Respects,
When a tabular battery is on a moderate load, what might be its voltage when is 50% drained.
Regards.
Hard to say. Depends on load, Battery health etc.
@@ZenInnovations Battery capacity digital meter might be a good idea?
Else, we should set cutoff voltage, say 11.5 volts for a good remaining charge to avoid deep discharge.
You may try those.
Nice. ❤
Thanks 😄
Nice 👍
Thanks ✌
👌👌👌👌
Thanks.
Ye battery konsi company ka hai? Micromax😂
Old batteries for testing only.
I am using UTL gama 1000va 24volt MPPT fan stop working when I register complain against this issue, mechanic came and put some lubrication oil and said it's ok now, I request to change the fan but they didn't change , after some time it's happen again again I made complain again same done by service mechanic. Service is not good of UTL
Goood
Thanks
1st view😁😁😍😍
WOW!@!
❤
👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌👌
Thanks
Bhai maine 550 watt ke 4 panel parallel mai install karaye jisme single panel ki voc aur amp hai 48v and 14 amp .....
Aab mera inverter 48 v toh show kar raha hai lekin current 16 amp show kar raha hai jabki parallel mai current add hota hai toh uss hisab se 4 panel ka current 56 ampere hua ...... maine clamp meter bhi laga ke dekha woh bhi 16 ampere show kar raha hai ....
Aisa kyu bhai mere panel ki power waste kyu ho rahi hai mujhe poora 48 volt aur 56 amp kyu nahi mil raha 😢🥺☹️ plz help
Apply good load on inverter & test.
Price Kya h
20000
Thanks 👍 bhadu mama