  • In this video we explain 3 phase keh meter connection practically
    In this video we use direct 3 phase keh meter by this we can measure actual KWH reading
    Also if we use more load connected to keh meter than how we can connect by MCCB Connected and also with MCB
    In this video we explain very easy method for more information learning about this topic just watch and learn
    Reverse forward starter power wiring connection
    • REVERSE FORWARD STARTE...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    3 phase rccb test on single phase supply practical
    • 3 PHASE RCCB मे SINGLE...
    3 phase ammeter connection with selector switch
    • 3 PHASE AMMETER CONNEC...
    8 pin relay testing with multimeter
    • 8 PIN RELAY TESTING WI...
    How to check ceiling fan common start run with multimeter
    • 3 WIRE CEILING FAN COM...
    How to make dol starter with relay
    • How to make dol starte...
    How to check ceiling fan common start run with series lamp
    • Video
    ammeter connection with current transformer
    • 3 PHASE AMMETER CONNEC...
    Cooler motor testing with series test lamp
    • COOLER MOTOR TESTING W...
    Street light timer setting
    • STREET LIGHT TIMER SET...
    Air compressure power & control wiring practically
    • AIR COMPRESSURE के ST...
    3 phase cable testing with megger
    • HOW TO CHECK CABLE INS...
    3 phase motor test with megger
    • Induction motor test (...
    Dol starter control from different points
    • MOTOR CONTROL FROM DIF...
    How to make reverse forward motor starter
    • How to make Reverse f...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    Thanks for watching

КОМЕНТАРІ • 71

  • @raininggaming1410
    @raininggaming1410 4 роки тому +1

    Nice bahut achcha is mobile per har Sara chij aap log batate Rahi 3 phase changeover connection future connection MCB ka connection

  • @viswanathancr2801
    @viswanathancr2801 3 роки тому +1

    good video

  • @akilshaikh1349
    @akilshaikh1349 4 роки тому

    Sir knowledge able vedio hai very good information I like it Thanks

  • @SonuGupta-iz8hu
    @SonuGupta-iz8hu 4 роки тому +1

    Bahut badhiya samjha

  • @mdhalim5078
    @mdhalim5078 2 роки тому

    Thank you very vari sho manch sir

  • @thelightoflife.7976
    @thelightoflife.7976 3 роки тому

    Thanks a lot sir for very easy & brief explanation.

  • @isaiahteye2305
    @isaiahteye2305 Рік тому

    Thanks so kindly sir , well understood

  • @chanbahaduraale3622
    @chanbahaduraale3622 3 роки тому

    Tq So much Sir Good Job

  • @aruntopno4524
    @aruntopno4524 5 років тому +1

    Upka explain accha laga

  • @hesbonsure3061
    @hesbonsure3061 Рік тому +1

    Next please do it in English, some of us don't understand

  • @samsukhan2092
    @samsukhan2092 4 роки тому

    Good

  • @vrv2652
    @vrv2652 5 років тому +1

    Thanks sir bahaut achchha samajh aaya

  • @mdmatiullh5871
    @mdmatiullh5871 4 роки тому

    Nice video

  • @lokeshbhaleraorv
    @lokeshbhaleraorv 4 роки тому

    Good job

  • @satyendrakumargautam1821
    @satyendrakumargautam1821 5 років тому +1

    I'm big fan on your teaching style. Sir pls 🙏 make video on plc and hmi communication

  • @riyangupta126
    @riyangupta126 4 роки тому

    Good explain

  • @ari91629
    @ari91629 5 років тому

    Bahut achaa bataya

  • @s.rshoaib4936
    @s.rshoaib4936 4 роки тому

    Thanks bro

  • @anilkumaryadav2885
    @anilkumaryadav2885 5 років тому

    Very nice

  • @arbazsheikh8972
    @arbazsheikh8972 4 роки тому

    Super sir

  • @ness8583
    @ness8583 5 років тому

    Nice bhia

  • @goutomsamadder8651
    @goutomsamadder8651 4 роки тому

    Nice sir

  • @alameensardar4906
    @alameensardar4906 3 роки тому

    thanksss

  • @derejefikre6548
    @derejefikre6548 5 років тому

    hi it is verey important

  • @Chandancprbr04
    @Chandancprbr04 5 місяців тому

    Sir agar CT operated meter ko direct supply diye bina CT ke to kya hoga sir?

  • @gurinderwadhawan2858
    @gurinderwadhawan2858 5 років тому +1

    Three phase motor k leya neutral connect karna jaroori hai Kya?

  • @bahadurbera619
    @bahadurbera619 4 роки тому

    Sir if one phase is cut out. Is meter will work properly?

  • @electricalfunda3501
    @electricalfunda3501 5 років тому +1

    thank u very much sir

  • @RavindraKumar-nd7hq
    @RavindraKumar-nd7hq 4 роки тому

    Sir kya energy Meter se mccb ke liye out put Lena jaruri h. Es ke bina energy Meter unit nahi bataega.mccb par load ke liye supply main line se bhi to le sakte h.pless reply sir

  • @pawansahu8467
    @pawansahu8467 4 роки тому

    Thanks sir

  • @technicalanuj9660
    @technicalanuj9660 3 роки тому

    Sir 30kW ke conetion me konsa meter lagta h 10ampr to 60ka ya 20ampr to 100ka

  • @Ameenkhan-kf3ee
    @Ameenkhan-kf3ee 4 роки тому

    Sir 3 phase miter ko ek jagah se dosre jagah sift kar sakte hai

  • @shripadbhujbal9604
    @shripadbhujbal9604 3 роки тому

    10 hp ke two motor means 20 hp load meter ke bad fuse section our 63 amp MCB use karake chala shakate hai kya ?

  • @mehtabengineering1683
    @mehtabengineering1683 4 роки тому

    Sir agar input me output lg jaye or output me input lag jayega to kya meter sahi reading dega?

  • @stanilks4412
    @stanilks4412 5 років тому

    In 3 phase meter RYB light are there. If R light is glowing means?

  • @wahidkhatib57
    @wahidkhatib57 5 років тому

    Thanks

  • @jitudas708
    @jitudas708 5 років тому +1

    Sir, ghar main over voltage kyon ata hai? Aur ghar ko over voltage se kaise protect karte hai? Please reply sir

  • @erpapun4227
    @erpapun4227 4 роки тому +2

    3 phase connection se ghar may single phase 220v fridge ac fan kaise chalaye?/

  • @anil-8710
    @anil-8710 3 роки тому

    3 fase or single fase charges ke bare mai betavo

  • @muhammadsaeed3854
    @muhammadsaeed3854 5 років тому

    Sir single phase meter pr hum maximum kitna load daal saktay hai aur three phase meter pr hum Ghar ka total load kitna daal saktay hai please tell me in easy way..... please please tell me sir

  • @akshaykalita7709
    @akshaykalita7709 5 років тому

    Thnq sir

  • @gohilyogirajsinh6261
    @gohilyogirajsinh6261 5 років тому +1

    Sir hamre ghar pe 240v atehe to curunt Kitna ayega.

  • @ashishyadav-pi2zn
    @ashishyadav-pi2zn 4 роки тому +1

    Sir energy meter ka.diagram banaye

  • @erbiswajitmaity1546
    @erbiswajitmaity1546 4 роки тому

    Sir please give me reason for what we connect the neutral point.

  • @mohammadgulphamahmad594
    @mohammadgulphamahmad594 5 років тому

    Kya hm push button aur selecttor switch laga sakte h

  • @sbhukta
    @sbhukta 5 років тому

    Max kitna load le sakte hein. 3phase par

  • @mrjitu-ws1jg
    @mrjitu-ws1jg 5 років тому

    अगर हम इनपुट के (main line)के nutarl में output का nutral जोड़ दे तो क्या परिवर्तन होगा reading कम होगी या नही या कुछ अन्य परिवर्तन आएगा

  • @rohitkhare1984
    @rohitkhare1984 4 роки тому

    Sir please tell me how to identify outgoing RYB and Neutral wire from meter

  • @kapilmahajan9216
    @kapilmahajan9216 5 років тому

    Mccb trip nahi hoti kya

  • @challengefitness-gz9bo
    @challengefitness-gz9bo 4 роки тому

    Ek motor ko do alag alag meter pr challani ho tho jaise a 1 mahina 1 meter pr 2month 2meter pr. Change over k thru

  • @appaaiwale8934
    @appaaiwale8934 4 роки тому +1

    sar 3 HP mortar ko kitna amp MCB lagega

  • @samrajahangir4635
    @samrajahangir4635 5 років тому +1

    kia 3 phase ka bill ziada ata
    plz reply

    • @SNTECHNICAL
      @SNTECHNICAL  5 років тому

      Ha jada aata h
      Jha hme 3 phase ki required hota h vhi lete h

  • @Kunalarya9412
    @Kunalarya9412 4 роки тому

    यह मीटर मिलेंगे कहा से

  • @sunilvaja7650
    @sunilvaja7650 4 роки тому

    Hi

  • @mwithsolger7
    @mwithsolger7 5 років тому

    Agar full tite NHi hoga to KY hoga

  • @puranelectrician2041
    @puranelectrician2041 4 роки тому

    हमारा 3 फेस का मीटर रीडिंग ज्यादा निकाल रहा है

  • @ajayyadav-qh7sc
    @ajayyadav-qh7sc 2 роки тому

    P

  • @mike-kuyakoy8943
    @mike-kuyakoy8943 4 роки тому

    I dont understand any single word from this vlogger