Liftgate Troubleshooting. Liftgate will not open or unfold.

Поділитися
Вставка
  • Опубліковано 19 бер 2023
  • Waltco WDV liftgate installed on semi-trailer only goes up and down. Open / close doesn't work.
    Video covers troubleshooting steps to take to identify a defective solenoid coil.
  • Авто та транспорт

КОМЕНТАРІ • 10

  • @tylerseabook9423
    @tylerseabook9423 7 місяців тому +1

    Thank you for this

  • @guillermotinoco5694
    @guillermotinoco5694 Рік тому

    Do you think we could manually move that pin where the solenoid moves whe we have the solenoid off, just for testing befor we install the new one?

    • @fleetrepairsolutions6372
      @fleetrepairsolutions6372  Рік тому

      Yes sir... After you remove the coil from the solenoid valve, remove the valve itself from the manifold block. On the side of the valve that was installed in the manifold block, there should be an opening. Insert a small screwdriver or other pointy poking device and push in and out. With medium force you should be able to move the piston back and forth freely about an 1/8 of an inch without it hanging up. ( I've actually had this fix a seized valve by manually cycling the valve.)

  • @jordanjordan5368
    @jordanjordan5368 Рік тому

    Where do you learn to work on lift gates? I am a mobile tech wanting to learn more thanks

    • @fleetrepairsolutions6372
      @fleetrepairsolutions6372  Рік тому +2

      For me it was just on the job experience. The company I work for services several fleets that utilize liftgates so I just had to learn. A good place to start is by downloading and reading the maintenance / service manual for the model of liftgate you want to learn about. They have a lot of good information and usually include a troubleshooting section.

  • @LuisMartinez-fb1fd
    @LuisMartinez-fb1fd Рік тому

    I have a Maxon lift gate stops working but when I kick tha box it works. Could it be the solenoid ? TIA

    • @fleetrepairsolutions6372
      @fleetrepairsolutions6372  Рік тому

      Doubtful...At least not one the smaller solenoids that just divert oil that is already being pumped by the motor. I'd be looking for loose electrical connections, particularly on the motor solenoid (the larger one attached to the motor). Also check the control switch wiring going into the pump box.

    • @durcell123
      @durcell123 Рік тому

      Some much room to work on . ILD suck.

  • @jackiechiles270
    @jackiechiles270 3 місяці тому

    Could there have bn a possibility it could have been SV2?

    • @fleetrepairsolutions6372
      @fleetrepairsolutions6372  3 місяці тому +1

      Doubtful. Given the symptoms SV1 had to be the issue. SV2 controls open and close, after oil is diverted from SV1. The fact that it was only going up and down told me the SV1 was not working.