Oddly Satisfying Electric Wires Installation | DIY Project

Поділитися
Вставка
  • Опубліковано 4 жов 2024
  • Explore a wide variety of content in our carefully curated UA-cam playlist: • Binge-Worthy Content
    If you’re enjoying this video, check out our other projects! Subscribe to our channel for woodturning, metalworking, restorations, remakes, epoxy resin projects and more. You name it, we do it!
    Subscribe to our channel → / totallyhandy
    Check our Shorts channel → / totallyhandyshorts
    #totallyhandy

КОМЕНТАРІ • 579

  • @TotallyHandy
    @TotallyHandy  Рік тому +36

    🌘🌘🌘 Check out our other video HERE: ua-cam.com/video/cSPv09O2zts/v-deo.html

    • @sandipmishra2178
      @sandipmishra2178 Рік тому +4

      Ll I have to pay the one I like Tarak chocolate o let us look diffrent to card and

    • @claudeleondiatta9602
      @claudeleondiatta9602 Рік тому +1

      😊😊

    • @AthulaBroElectrical
      @AthulaBroElectrical Рік тому +1

      Ask me anything about house wiring. Thanks and best regards

    • @سعيدالبطاشي-ف5ص
      @سعيدالبطاشي-ف5ص 5 місяців тому

      .❤❤😂😢 ‏‪2:08‬‏ ​

    • @RoddyRich-hc6sb
      @RoddyRich-hc6sb 3 місяці тому

      I am so happy to see you Fixing this main switch .please I’m electrician and I need a job ,so when I see you today and I said make me ask maybe u can get some for me even I can see that you are a good electrician .please am from Ghana and I known that you will ripple me when you see this massage thank you.

  • @danieljunge5522
    @danieljunge5522 Рік тому +573

    As an electrician I'm crying to see that many mistakes at once

    • @jacksonroad9263
      @jacksonroad9263 Рік тому +23

      as a handyman im laughing at the video too

    • @kaijnk
      @kaijnk Рік тому +11

      Ha ha ha. Sorry for home owner.

    • @fletrcarr
      @fletrcarr Рік тому +6

      Hahaha me too😂

    • @Zpoody
      @Zpoody Рік тому +4

      I have to agree.

    • @danilomanrique3853
      @danilomanrique3853 Рік тому +7

      at least he used conectors 😂

  • @MultiKlompen
    @MultiKlompen Рік тому +126

    0:39
    NO! Never cut it that short!! Never!

    • @jacklancer8317
      @jacklancer8317 Рік тому +7

      I'm curious as to why you say that?

    • @FXArts
      @FXArts Рік тому

      Why please?

    • @eisenklad
      @eisenklad Рік тому +11

      @@FXArts in case you need to add more breakers or replace a faulty breaker.
      during such scenarios, the electrician will cut off the ends because its already weakened during installation. if the core of the wire(the copper) breaks, a small arc may occur in the wire and lead to a fire.
      if a wire is short, one will have to use more connectors to extend existing wires but its not great( more point of failures)
      alternative is to run a new wire(costly and time consuming)

    • @FXArts
      @FXArts Рік тому

      @@eisenklad Thanks

    • @IAmThe_RA
      @IAmThe_RA 8 місяців тому

      ​@@FXArtsAnd this board cannot fit RCBOs because he cut the wires so short especially the blue wires (neutrals). Unlike MCBs, RCBOs need both the phase and neutral of the circuit to go in its phase and neutral terminals (output).

  • @ranugsielprep1550
    @ranugsielprep1550 Рік тому +186

    The cable cross-sections for the supply of the automatic circuit breakers (above) are wrong. In Germany there are 3-pin prefabricated copper bridges for this. The blue wires for the N busbar have been cut too short without any reason. There should be more reserve loop behind the circuit breaker. While the work looks good, it is technically critical.

    • @MilanTheMan69
      @MilanTheMan69 Рік тому +3

      5:55
      Lol 😅

    • @jacksonroad9263
      @jacksonroad9263 Рік тому +5

      as a handyman those are the wrong wires for the switch board. good luck running more than 30amps

    • @psatyanarayana3686
      @psatyanarayana3686 Рік тому

      @@MilanTheMan69 .

    • @ioanmariusbozga
      @ioanmariusbozga Рік тому

      6kw

    • @Devviiiii
      @Devviiiii Рік тому

      And its a C10A and after that a B16, love that, short circuit failures will always trigger the C10 and you never now, which circuit it was. and all the other brakers are wired with live wire instead of all of them with the same load....

  • @Fatpumpumlovah2
    @Fatpumpumlovah2 4 місяці тому +11

    THIS VIDEO NEEDS MASS REPORTING FOR HARMFUL AND DANGEROUS ACTS!!!

  • @alewhitesnake
    @alewhitesnake Рік тому +123

    Beautiful job, but:
    - wire diameters are certainly not correct
    - feeding the breakers by jumping wires isn't the best solution at all
    - you should use wire terminals for the connections
    This video is actually teaching how to set your circuit on fire. At least it's a beautiful circuit.

    • @ljubomirculibrk4097
      @ljubomirculibrk4097 Рік тому +1

      There are nice insulated thick coper flat rails, no chance of arcing or owerload.

    • @nowonmetube
      @nowonmetube Рік тому +3

      Guys I'm lost. People put electrical installation videos online and there's always someone who says people put things on fire. It works though. So what are they on about? Does it work or cause fires or what? Also please don't use too many technical terms, I don't understand everything.

    • @AustrianDeathMachine9
      @AustrianDeathMachine9 Рік тому +2

      @@nowonmetube if a circuit pulls too much amperage, it can cause immense heating of certain gauge wires. A thicker gauge wire means more amperage.

    • @AustrianDeathMachine9
      @AustrianDeathMachine9 Рік тому +7

      @@nowonmetube jumping wires on a breaker is also not a great idea, buss bars a more commonly used

    • @andrasbradacs6016
      @andrasbradacs6016 Рік тому +7

      @@nowonmetube Add up all the amperages to the first jumperwire next to the first breaker and you will know why is not a great idea to use jumperwires…

  • @kostadinkostadinow9319
    @kostadinkostadinow9319 Рік тому +41

    Having 3 phase power but using only the closest phase. Totally handy to set your house on fire...

  • @darraghljordan3259
    @darraghljordan3259 Рік тому +20

    Tks for showing us the propper way to start a fire

  • @gabriellando1
    @gabriellando1 Рік тому +27

    As an electrician engineer, I'm catching fire right now.

  • @cristianjrojas
    @cristianjrojas Рік тому +65

    That electric panel looks very dangerous, one thin wire to power every circuit?

    • @patrickcannell2258
      @patrickcannell2258 Рік тому +13

      Not compliant at all. DIN busbar is correct covered by a 63A main. This board is a fire 🔥 looking for a time to happen!

    • @PedroFaria
      @PedroFaria Рік тому +3

      Maybe it's an example of how it should be layed out and connected and not about the power and amps. At the end he turns on a bunch OU lights that, being LED and at 240v, 1,5mm2 wires are plenty. Xp

    • @afcl1984
      @afcl1984 Рік тому +7

      Jesus, putting a board example like this online... Totally wrong.

    • @freshersofbose456
      @freshersofbose456 3 дні тому

      At minimum load . No problem at all

  • @grannywaffle
    @grannywaffle Рік тому +13

    1:53 wwooooaaah hold up there sonny Jim, did you just link all the breakers for the property in 1.5mm? Toasty 😂

    • @darraghljordan3259
      @darraghljordan3259 Рік тому +1

      He was trying to make a heater😂

    • @DavidKbst
      @DavidKbst 10 місяців тому

      ​​@@darraghljordan3259Hi, can you please explain me this? Why si more current on the jumper near supply on the right side?

    • @tristan6509
      @tristan6509 7 місяців тому +1

      ​@@DavidKbsthe's putting the load of every breaker in that row through a single 1.5mm wire...

  • @константинколесник-м8э

    По ПУЭ должен быть запас провода как минимум на ещё одно подключение,тут как то в обрез совсем...

  • @rhysferris1996
    @rhysferris1996 Рік тому +10

    And this is why (In the UK at least) a consumer Unit has to be installed by a qualified electrician. You won’t get a installation certificate or a satisfactory EICR because this consumer unit is just a fire hazard. I don’t think an EICR has enough space to list the issues with this install. I am not yet fully qualified and I can see many issues with this install.

    • @cjmillsnun
      @cjmillsnun 4 місяці тому

      I'm not qualified at all and can see it's dangerous.

  • @barrydonnelly4790
    @barrydonnelly4790 Рік тому +7

    Jaysus you're putting some faith in them 1.5 or 2.5 singles linking your breakers 🤣

  • @ДиманЧереповский

    Руки бы оторвать за такую работу

  • @Ytofmayachev
    @Ytofmayachev Рік тому +17

    Make sure to ask to an electrician which cross section to use before DIYing, i beg all the watchers. White the edit of the video is great, the way the materials are chosen and assembled is beyond dangerous, especially in the electrical board part.

    • @Dobai1
      @Dobai1 Рік тому +1

      Formula for that is pretty simple, you multiply the section area of the conductor with 7 Amps/mm2 and there you have it. 10.5 Amps for 1.5 mm2 conductor, 17.5 Amps for 2.5 mm2. What goes above 4 mm2 is calculated with a different formula. But it can withold around 9KWh in continuous consumption.

    • @Ytofmayachev
      @Ytofmayachev Рік тому +3

      @@Dobai1 I am an electrician.
      This formula doesn't account for tension loss over lenght or short circuit values, which are absolutly necessary for a stable and secure installation.
      While there are ways to circumvent those problems without changing the cross section of a cable, it feels safer to encourage talking to an electrician for tips especially in a comment section.

    • @IAmThe_RA
      @IAmThe_RA 11 місяців тому

      ​@@Ytofmayachev The biggest wire used in this distribution board looks like 2.5mm². I hope the main isolator switch has a 16A fuse otherwise this whole installation is a fire hazard. Standard is on the floor. What country is this?

  • @West_Kootenay_railfan
    @West_Kootenay_railfan Рік тому +4

    9:49 There's a thing called a wood burner you can buy for cheap instead of burning your house down by messing with 120 or 240 ac or 340 ac depending where you live.

  • @Lee-xs4dj
    @Lee-xs4dj Рік тому +7

    Let's just hope the input tails are covered by a 12amp breaker on this board

  • @СергейЭлектрикМосква-й6л

    Перемычки выполнены каким сечением? 1,5 мм2?

  • @taimoorshah8230
    @taimoorshah8230 Рік тому +10

    never use a wire to jump circuit breakers. its insane how thin the wire is which he used without thinking twice.

  • @lasphalteur
    @lasphalteur Рік тому +6

    Fire in 3…..2…..1…..🔥

  • @ricardomoraes8874
    @ricardomoraes8874 Рік тому +2

    Deixou sem recurso pra manutenções... fios muito curtos. Derivou tudo de uma única fase... e não entendi pra que pôs dois disjuntores trifásico em série

  • @МистерХ-л1б
    @МистерХ-л1б Рік тому +8

    Это видео о том, как не надо делать. Нельзя делать перемычки кабелем того же сечения.

    • @ВладимирДомин-в5ц
      @ВладимирДомин-в5ц Рік тому

      Перемычки то он сделал по правилам - того же свечения что и кабель ввода - а вот он - кабель ввода - заниженного сечения

    • @МистерХ-л1б
      @МистерХ-л1б Рік тому

      @@ВладимирДомин-в5ц нет. Явно перемычки сделаны тем же кабелем, что и разводка. Перемычки в принципе колхоз.

  • @electromag95
    @electromag95 Рік тому +3

    Когда ещё не было в каждом магазине гребенок, соединяли АВ с помощью перемычек. Только делали перемычку неразрывной.

  • @reedy8585
    @reedy8585 Рік тому +3

    Using single wire jumpers to feed the breakers is a fire hazard as you have overloaded the wire you should be using a bus bar rated for the supply usually 100 amps

  • @oleksandrponomarov2437
    @oleksandrponomarov2437 Рік тому +7

    На 1:48 где куча перемычек на фазу. Такие делать нельзя. Нужно использовать либо перемычки из более толстого провода, либо специальную шину. Если делать как на видео, при мах нагрузке на все автоматы, соединенные такими перемычками, сгорят первые (справа) перемычки.

    • @ДобряковКухарит
      @ДобряковКухарит Рік тому

      А я уже думал,что только меня смутило сечение провода на перемычки) Но судя по номиналам этот щит исключительно на освещение,и каждый автомат питает отдельную лампочку)

    • @1231-m7f
      @1231-m7f Рік тому

      Нужно использовать сечение провода который будет вывозить суммарный ампераж всех соединённых автоматов? А в чем еще плох этот электрощит?

    • @DavidKbst
      @DavidKbst 10 місяців тому

      Hi. Can you expain me please why jumper on the right start fire? Why not jumper on the left?

    • @yfpdfybt
      @yfpdfybt 4 місяці тому

      @@DavidKbst Питающий кабель подведен с права... через первую правую перемычку пойдет весь ток... через вторую с права весь ток за исключением того что пойдет через первый справа автомат... и так далее.

  • @ta3aloumsat
    @ta3aloumsat Рік тому +1

    تحياتي اخي الكريم من قناة تعلوم سات تحياتي

  • @mananraval3506
    @mananraval3506 Рік тому +1

    I Am from India. I am Electrisian.
    Electrical Distribution box Connections method is good but all M.C.B's incoming power wire link connect MCB's Down terminal not up Terminal. As per my knowledge.

  • @СтаниславИванов-ю9е

    Запаса вообще не оставляешь, как это потом ремонтировать если сгорит?

  • @ZloySok
    @ZloySok Рік тому +1

    Сразу видно профи за работой.....
    1. Оболочку кабеля режет ножом.
    2. Подозрительно тонкое сечение кабеля на групповые автоматы. Да и вводной кабель тоже странный учитывая количество автоматов.
    3. Перемычки короткими обрезками. Если готовые шины еще не выучил, сделай хотя бы цельным отрезком провода,а не огрызками.
    4. клещи для зачистки нужно другие( именно эта модель плохая, есть лучше варианты), они изоляцию портят, как зубами кусали.

  • @marcelo_rcosta
    @marcelo_rcosta 6 місяців тому

    1:45 o serviço ensina a trabalhar.
    Excelente montagem!
    Lembra da primeira que fez?
    Quantos erros.
    Quanto tempo levou.
    Não ficou uma obra de arte como essa.
    A prática leva à perfeição.

  • @romycruz4498
    @romycruz4498 10 місяців тому

    now, that's the way it should be. excellent !

  • @marekvisser3311
    @marekvisser3311 Рік тому +6

    For me as a German electrician master this is far from satisfying but still much better than average. Keep improving

  • @leonnegro4226
    @leonnegro4226 10 місяців тому +1

    Guau. Que país será ese que todavía siguen usando conductores de 1 solo hilo. Es prehistórico. Será algún país del tercer mundo.
    Saludos cordiales.

  • @cristogil4537
    @cristogil4537 Рік тому +1

    Ese cable tan fino trae la derivación individual al cuadro

  • @sr.navarro7859
    @sr.navarro7859 Рік тому +2

    Ese cuadro eléctrico en España incumple toda la normativa de seguridad

  • @aliahmedjan1135
    @aliahmedjan1135 Рік тому +1

    I like your good joob

  • @sanvigameing1082
    @sanvigameing1082 Рік тому +1

    First video me apne Jo cutter use Kiya h , available hai ky meko chahiye

  • @kolobok2440
    @kolobok2440 Рік тому

    Граждане специалисты - еврофанатики супер - пупер любители устанавливать кучу всяких узо , напряженческих реле и расцепителей, учитесь делать щитки так же просто , красиво и надежно!!!

  • @technics6215
    @technics6215 Рік тому

    I became electrican because electrical equipment is soooo cool :)

  • @cheryljason9617
    @cheryljason9617 Рік тому +5

    Only thing satisfying is it ended that music... nice clean job especially for a younger generation electrician... I'm a electrician of 25 years in America either way that's one of the cleanest panels I've seen

    • @tukituki9537
      @tukituki9537 Рік тому +3

      Please, STOP working, if you like it

  • @Grigory_Protsuk
    @Grigory_Protsuk Рік тому +9

    Перемычки на автоматах зло, есть фазная шина, нет запаса в проводах на второе подключение к автомату, ншви на многожилку обязательно, сечение проводов в щите подозрительно мало

    • @santoz71
      @santoz71 Рік тому +2

      шина медная есть на это дело

  • @rams5474
    @rams5474 Рік тому

    Things are connected with art. Eating comes with design colour appealing and patterns. So also wiring with a design and art concept is really a job satisfaction. Self interest in any work is primary. Even in corporate they go for design and chart rather than numerical statistics report.

  • @Idorapontheweekends
    @Idorapontheweekends Місяць тому

    You lost me when you used singles for bus bar😂

  • @minutemaker0
    @minutemaker0 2 місяці тому

    Nice to see very nice BDO bro. I am trying and I will pray for everyone inshallah

  • @one.tap.-2667
    @one.tap.-2667 Рік тому +2

    The First Clip: U can run to the jail when u Do it like that. .... Normaly u use a 10qmm Phasenschiene

  • @GoodManJames-z5l
    @GoodManJames-z5l 7 місяців тому

    Since the MCBs Miniature Circuit Breakers have different rating, you could have utilized busbar to connect between them much more better. Jumper cables with the some cross sectional area are not safe.

  • @gino2465
    @gino2465 Рік тому +1

    That's a lovely job, bit confused to see all those wires tightly packed together in the conduit.

    • @BigHunt206
      @BigHunt206 Рік тому +4

      It's Alot easier than you think, he actually made many mistakes.

  • @guffermeister
    @guffermeister Рік тому +11

    Why run three phase to the unit and only use one of it? Why type C breakers? These have much more stringent Zs readings to ensure they trip in time - a problem if you have long cable runs at times. Only usually required if you have high inrush situations that would cause a B type to trip too easily

    • @AthulaBroElectrical
      @AthulaBroElectrical Рік тому

      Ask me anything about house wiring. Thanks and best regards

    • @IAmThe_RA
      @IAmThe_RA 11 місяців тому

      Type c is the most common in the world. As far as i know only the UK where type B is common.

  • @electrokomtech1441
    @electrokomtech1441 Рік тому +2

    It's cool,but Don cut too short ,ensure there is some allowance for maintenance in cable part,overall it's cool

  • @mariusreit305
    @mariusreit305 Рік тому +2

    La coupure unipolaire est interdite en France, vous devez couper la phase et le neutre en même temps

  • @philopatepataphil6696
    @philopatepataphil6696 Рік тому +1

    Type de branchement qui ne se fait plus en France car la coupure est unipolaire donc dangereuse. Ce type de branchement est interdit depuis plus de 40 ans en France. Peut être est ce du au régime de neutre. Dans ce cas il faudrait le préciser.

  • @HristovRumen
    @HristovRumen Рік тому +3

    Unless all of these wires are powering lights of equal load size, this would be insane to wire like that without tracing and labeling each wire. That's a lot of lights, if they are indeed all lights. Hopefully, they're all 5W led's as otherwise, you wouldn't want to have all of them on, or your bridge power feeds between the breakers will soon be all melted.

  • @JamesBrown-rm2rd
    @JamesBrown-rm2rd Рік тому +2

    unless they are low voltage, I would never run wires underneath, a buse bare or breaker bars, if the breaker should go bad and heat up the wires are right behind them,but whatever make your movie.

  • @АлексеВерхозин
    @АлексеВерхозин Рік тому +2

    Всё красиво где запас провода!

  • @dapxdap110
    @dapxdap110 Рік тому +3

    Какой смысл ставить пакетник на 16a и за ним на калдую линию 16A?

  • @KG-gg8rl
    @KG-gg8rl Рік тому +1

    I have no idea what you are doing - could be incredibly dangerous for all I know? But it looks lovely.

  • @almanyaulmdeturkailesi6934
    @almanyaulmdeturkailesi6934 3 місяці тому

    Süper bir model
    Güzel bir video olmuş….

  • @المهندسلتعليمالكهرباء

    ماشاء الله

  • @philippeberenger257
    @philippeberenger257 6 місяців тому

    Complètement illégal en Europe !!!

  • @ДмитрийКондратьев-п9ф

    Где маркировка проводов? Или все равно в какой автомат и что пихать? Ну а вишенка на торте, это перемычки!!! Ты купил щит, купил провода и автоматы, а на шину денег не осталось!!!! У тебя вроде изолированный приличный инструмент. Но перемычки это конец.

  • @ВладимирГринченко-ц3ы

    Перемычкой в шкафу должны выполняться диаметром побольше. Иначе пожар!!!

    • @stariyhopper
      @stariyhopper Рік тому

      Вообще лучше ставить шину а не экономить.

  • @Sanya231986
    @Sanya231986 Рік тому +5

    У меня все сжалось когда он над ладонью начал прорезать оболочку кабаля🤔🙄

    • @alekssamsonov5722
      @alekssamsonov5722 Рік тому

      Я тоже думал, что кровищи не избежать! Повезло парню!)

    • @santoz71
      @santoz71 Рік тому +1

      есть нож с лопаткой спецовый.

    • @Anisimov_Yu_M
      @Anisimov_Yu_M Рік тому

      да, кабель жалко

  • @КириллТимощенко-с1я

    Yes it's beautiful. but we can break our hands for this

  • @goodpeople6433
    @goodpeople6433 Рік тому

    다른 나라의 전기배선 방법 잘보았습니다. 생각지 못한것도 있고 비슷한것도 있네요.

  • @noelbyrne8735
    @noelbyrne8735 Рік тому +1

    Where to start with the oh so many mistakes made here. I’ll mention one, a very basic lesson learned on the job and in trade school. A single termination of a solid core copper wire should be folded over, especially when being terminated into such a large terminal like an MCB.

  • @dimasemilov7426
    @dimasemilov7426 Рік тому +1

    Всегда бы с такими проводами работать в щите!

  • @obaidulrahman3685
    @obaidulrahman3685 Рік тому +1

    Good video.More video new

  • @BangMandor46
    @BangMandor46 Рік тому

    Good very good amazing thank for your

  • @CreativeIdeasMaker
    @CreativeIdeasMaker Рік тому +2

    Every time we watch your videos, we find interesting educational tips and get energy from watching you.

  • @sprivet
    @sprivet Рік тому +3

    В НШВИ провода нельзя скручивать перед обжимной

  • @deusdetefranciscodesouza8099
    @deusdetefranciscodesouza8099 Рік тому +4

    Quando a pessoa tem o dom de fazer bem feito ele já vem de berço parabéns 🎉🎉🎉

  • @DestroyerSTK
    @DestroyerSTK Рік тому +8

    То самое чувство, когда нагружают 1 фазу из 3-х, а остальные НОЛЬ нагрузки! Такому электрику нужно на "булках" межфазку сделать...

    • @KOJIXO3NICK
      @KOJIXO3NICK Рік тому

      Ага, а ещё он, о Боже, канцелярским ножом кабель зачищает и запас по длине жил маленький 😁

    • @ИринаВасильева-ы8в
      @ИринаВасильева-ы8в Рік тому

      А это нормально, что он на медный провод обжимки из другого металла использует? Что это за металл, можете подсказать? Это допустимо?

    • @user-pd4ke6gk1t
      @user-pd4ke6gk1t Рік тому

      Я думал по феншую, так себе сделал

    • @dimondiablo9644
      @dimondiablo9644 Рік тому +2

      @@ИринаВасильева-ы8в это луженая медь

    • @ИринаВасильева-ы8в
      @ИринаВасильева-ы8в Рік тому

      @@dimondiablo9644 спасибо за ответ!

  • @phuturephunk
    @phuturephunk Рік тому +1

    How exactly does homes know which cable is going to which zone in the first installation?

  • @sanatbekegambergenov7559
    @sanatbekegambergenov7559 Рік тому +1

    Very good jobs

  • @MF-kk2cj
    @MF-kk2cj Рік тому +1

    good skills

  • @rishirajupadhyay1704
    @rishirajupadhyay1704 Рік тому

    With that much detailing I was expecting to see an artwork of someone's face or something. Still pretty cool though. :P

  • @aleksandrmozgovoy1167
    @aleksandrmozgovoy1167 Рік тому +3

    Перемычки вместо гребёнки)))

  • @Fuck__Russia
    @Fuck__Russia Рік тому +43

    1:42 - Those repeated single brown wire bridges on top of the circuit breakers should be avoided at all cost, because the nearer the bridge to the supply spot, the more current. In a nutshell, a 1.5mm² wire supplies a dozen circuit breakers. This is insane.

    • @АлександрСергеевич-ч3о
      @АлександрСергеевич-ч3о Рік тому

      На перемычки нет нагрузки,я подобные щиты собирал и каждый год провожу осмотр,всё в порядке

    • @evgeneevgen8177
      @evgeneevgen8177 Рік тому

      @@АлександрСергеевич-ч3ону если в квартире где две лампочки и один чайник то можно и так😂😂😂😂😂хотя еслибы мне собрали такое говно как этот щит я бы просто не заплатил за такую работу😂

    • @IAmThe_RA
      @IAmThe_RA 11 місяців тому

      I think those are 2.5mm² conductors. This is probably dutch electrics, i think i was told by some that in netherlands they use 2.5mm² conductors for both lighting and power circuits, smaller conductors are not allowed.

    • @DavidKbst
      @DavidKbst 10 місяців тому

      Hi. Can you explain me why is near the supply spot more current? Why not on the left side?

    • @Odisovic
      @Odisovic 6 місяців тому

      it depends on the project documentation, where the designer has specified for what output load he has designed the switchboard.
      Even in Slovakia it is true that you do not design for the maximum, but for the operation that is expected.
      So to say it is wrong is nonsense, if you are serious and you look at the manufacturers products, if one bridge is for 63A and another for 80A, which one would you put?
      If you don't know what's in the project documentation, then to jump to conclusions that something is wrong shows more likely that you have no idea what you're talking about and are just a "screwdriver user" and not an electrician ;)

  • @adamgregory3325
    @adamgregory3325 Рік тому +1

    Cables are not long enough, should allow much more for re-termination amongst other faults!! 😮

  • @firozmulla4512
    @firozmulla4512 Рік тому +1

    Superb........

  • @elassrimohammed5600
    @elassrimohammed5600 Рік тому +2

    Pravo,
    👍👍👍👍👍👍🇭🇺🇲🇦🌹🌹🌹🌹🌹🌹🌹

  • @1.hturmgewer
    @1.hturmgewer Рік тому +2

    Запаса провода не оставлено, одноразовая сборка не ремонтно пригодна. Сечение питающего кабеля маловато.

  • @oportoz
    @oportoz Рік тому +4

    Ерунда, запаса нет от слова совсем. Перемычки из проводов = автор живёт в 18 веке и про шину не слышал.

  • @mohammedishayo1801
    @mohammedishayo1801 4 місяці тому

    Best way to start a fire (did you remember the song “somebody call 911”)

  • @gervaziovieira9764
    @gervaziovieira9764 Рік тому +1

    Very good.

  • @bargh.karimi9359
    @bargh.karimi9359 Рік тому +1

    عالی 💡💡👍👍👍

  • @1.hturmgewer
    @1.hturmgewer Рік тому +2

    Интересная зажигалка!

  • @amabsalom251
    @amabsalom251 Рік тому +1

    good job

  • @grantwhebell7730
    @grantwhebell7730 Рік тому +1

    After cutting everything to the exact length what happens if you have to start moving wires ? This is nonsense

  • @darraghljordan3259
    @darraghljordan3259 Рік тому +1

    The main cable is ready to explode 💣 💣

  • @ИгорьШатров-н9ь
    @ИгорьШатров-н9ь Рік тому +1

    Извенити НО Вы допустили ошибку:1)-перемычки с разрывом,2)-перемычки вообще не должно быть

  • @AntonyoKnight
    @AntonyoKnight Рік тому +1

    It's nonsense. Just an oddly satisfying video and a dangerous installation...

  • @edilsonjesus-yl9ne
    @edilsonjesus-yl9ne Рік тому +1

    Bom parabens ótimo bom

  • @Tselectricals
    @Tselectricals Рік тому

    Very nice presentation bhai ❤❤❤❤❤❤❤❤

  • @francescoinnamorati9591
    @francescoinnamorati9591 Рік тому +1

    Se questo lavoro di cablaggio si faceva alle scuole professionali...

  • @КаренГаспарян-э7н

    Удвоивайте провода,вы собирайте не верно,так нету площадь прикосновение и всё будет перегореть

  • @rogeriom2024
    @rogeriom2024 Рік тому +4

    Canal, parabéns! Estamos vendo que o profissional para ser bom tem que ter o dom. SHOW!

  • @afonsobatistadealmeidaalme3798

    Eu adoro fazer escalações muito bom está de parabéns

  • @alexdiver9809
    @alexdiver9809 4 місяці тому

    Отличное видео КАК НЕЛЬЗЯ ДЕЛАТЬ.