Mitsubishi PLC to PLC Communication over Ethernet

Поділитися
Вставка
  • Опубліковано 27 лис 2019
  • This function allows data communications between specified devices at the specified timing just by setting simple parameters from the engineering tool for the CPU module. Specify one device (transmission source) to one device (transmission destination). The communications are performed between the specified devices.
    ---------------------------------------------------------------------------------------------------------------------------------------------------------------
    Program Sample At:
    automationsolutions.tk/
    automationsolutionz.blogspot....
    Download Sample Section
    ---------------------------------------------------------------------------------------------------------------------------------------------------------------
  • Наука та технологія

КОМЕНТАРІ • 56

  • @peterlustig1364
    @peterlustig1364 3 роки тому +2

    Man im loving this new simple plc communication. Makes my life so easy.

  • @majidumarov3602
    @majidumarov3602 2 роки тому

    Thanks a lot for video!!! It helps me

  • @supamit1992
    @supamit1992 4 роки тому +1

    Nice. Thank you .

  • @bobeldukla
    @bobeldukla 4 роки тому

    Super. Thank You

  • @zellerautomationandplc
    @zellerautomationandplc 2 роки тому

    Thank you sir. What is the fastest execution time setting possible for sending and receiving from one plc to another?

  • @stevep3171
    @stevep3171 4 роки тому

    Thank you for the informative video! Will these settings work for communication between Q and FX5U PLCs as well?

    • @Technocrats91
      @Technocrats91  4 роки тому

      Yes it can work for all 3E Frame compatible devices

    • @stevep3171
      @stevep3171 4 роки тому +1

      @@Technocrats91 Awesome! And thank you for the quick reply! Definitely going to subscribe!

  • @Kurogane-el2vq
    @Kurogane-el2vq 2 роки тому

    So does this work as communication between master and another master PLC ? And not under master-slave configuration.

  • @edutech2463
    @edutech2463 2 роки тому

    sir Will these settings work for communication between fx5u plc with any other device??????

  • @yogeshrajput4559
    @yogeshrajput4559 4 роки тому

    Superb ! Do you know how to communicate over Ethernet IP between AB Plc and Mitsubishi using Ethernet configuration tool , while I am using RJ71EIP.... Ethernet module , can’t actually figure out Class1 am Class3 tag communication!

  • @martinputra8884
    @martinputra8884 3 роки тому +1

    Can this communication method work between Multiple set of QCPU + QJ71E71-100 and an FX5U?

  • @krs8595
    @krs8595 3 роки тому

    Can't find simple plc setting.. I am using gxworks3 version 1.038Q

  • @ramkumarh9312
    @ramkumarh9312 3 роки тому

    Hi , please explain how to use this when Communication setting execution interval is set to "On Request" , instead of fixed

    • @Technocrats91
      @Technocrats91  3 роки тому

      As of now communication setting is fixed only, You can use socket communication for On request communication

  • @kimetohoyaei8788
    @kimetohoyaei8788 3 роки тому

    How many PLC can be connect ?

  • @akrammpes8312
    @akrammpes8312 3 роки тому

    can we do this similar connection in gxworks 2 also?? and how its physical connection should be??

    • @Technocrats91
      @Technocrats91  3 роки тому

      yes it is available in gxworks 2, for q & r cpu

  • @bobeldukla
    @bobeldukla 4 роки тому

    Hi. I can't to write to 1st PLC program. There is written: Simple PLC Communication Settings has been enabled.... :-(

  • @pumppanel3100
    @pumppanel3100 3 роки тому

    hi ! you can simulator communication fx5u and modbus tcp?

  • @edutech2463
    @edutech2463 2 роки тому

    sir can we do both cclink and ethernet communication with same plc ????

  • @edutech2463
    @edutech2463 2 роки тому

    sir Will these settings work for communication between fx5u plc with any other device??????
    @ technocrats

    • @Technocrats91
      @Technocrats91  2 роки тому

      Other devices which can communicate are mentioned in setting

    • @edutech2463
      @edutech2463 2 роки тому

      OK thank you sir

    • @edutech2463
      @edutech2463 2 роки тому

      @@Technocrats91 sir can you upload video of fx5u plc communication with other device ethernet communication setting?????

  • @mrirfan-gz6dq
    @mrirfan-gz6dq 3 роки тому

    how to do this in GX works 2?? can you show it for GX Works 2? please, thank you

    • @Technocrats91
      @Technocrats91  3 роки тому

      Simple Plc communication is available for q plc and ethernet card.
      Go to parameters, you will find simple Plc communication settings

  • @faruknizamoglu5491
    @faruknizamoglu5491 4 роки тому

    I can not find "Simple PLC Communication Settings " in my GxWork3... How to add that?

    • @Technocrats91
      @Technocrats91  4 роки тому

      Update Gxworks 3

    • @ibrahimnizamoglu768
      @ibrahimnizamoglu768 4 роки тому

      @@Technocrats91 Çöynü, I have version GXwork3 1.0380 What version do you use?

    • @Technocrats91
      @Technocrats91  4 роки тому

      1.055H

    • @ibrahimnizamoglu768
      @ibrahimnizamoglu768 4 роки тому

      @@Technocrats91 I updated the GXwork3 and solved the problem. Thank you so much for your help

  • @mohammedaziz2020
    @mohammedaziz2020 4 роки тому

    Do u have any tutorial for cc link

  • @lodhisami
    @lodhisami 3 роки тому

    Can you guide me how to do this in Gx works 2 for fx3u PLC

    • @Technocrats91
      @Technocrats91  3 роки тому

      FX3u Does not have simple plc communication function, you can use socket communication

    • @lodhisami
      @lodhisami 3 роки тому

      @@Technocrats91 Thanks for your prompt reply But I don`t seem to find socket communication setting in gx works 2, my selected plc is FX3U can you kindly guide further?

    • @Technocrats91
      @Technocrats91  3 роки тому

      contact me @ facebook.com/technocrats.nil.3

  • @rameshaatla7072
    @rameshaatla7072 3 роки тому

    While doing this for fx5u and iq+r series it showing simple plc communication setting enable for that it is not write to plc suggest how to solve this

    • @Technocrats91
      @Technocrats91  3 роки тому

      Simple plc communication require firmware version 1.210 or above, check your PLC's firmware version

    • @Technocrats91
      @Technocrats91  3 роки тому

      This is for fx5u

    • @Technocrats91
      @Technocrats91  3 роки тому

      For R cpu its firmware version 35

    • @rameshaatla7072
      @rameshaatla7072 3 роки тому +1

      I checked with my place it showing 1.069

    • @Technocrats91
      @Technocrats91  3 роки тому

      Update the firmware