Mitsubishi GS2107 WTBD connect ethernet with FX5U

Поділитися
Вставка
  • Опубліковано 12 сер 2024
  • It takes only a few minutes to set up the communication between a Mitsubishi Melsec FX5U CPU and the GS2107-WTBD touch screen also from Mitsubishi electric. This video explains how easy and fast it is to do this setup.
    0:00 Intro
    0:49 New Project in GT Designer 2
    1:15 Set the Controller Type in GT Designer 2
    2:08 Set the GOT IP Address
    2:50 Set Up new Project in GX Works3
    3:22 Set Parameters for Communication
    3:55 Controller Settings in GT Designer
    4:34 External Device Configuration in GX Works 3 for setting the communication to the GOT
    5:40 Write a Program for the Simulator Mode in GX Works 3
    6:22 Write a Program for the Simulator Mode in the GT Designer 3
    7:35 Start the Simulation Mode
    8:32 Create a Watch List in the GX Works3
    9:30 What happens in Simulation Mode if the Communication does not work?
    Since these videos are created for the free usage of every one here at youtube i have a little friendly request to you.
    To support me doing what i do, to support you:
    / gerdzeller
    Zeller Presscontrol Systems
    Gerd Zeller
    Tel. +49 170 961 6819
    www.zeller-presscontrol.com
    info@zeller-presscontrol.com

КОМЕНТАРІ • 19

  • @zellerautomationandplc
    @zellerautomationandplc  3 роки тому +2

    The Ethernet Communication between an Mitsubishi Melsec FX5U and the HMI GOT and GS Series is done very fast.

  • @tedwow2625
    @tedwow2625 5 місяців тому

    Thank you so much for this thorough tutorial! it really is a life saver!!!

  • @IntelLectualChip
    @IntelLectualChip Рік тому +1

    Fantastic! Greetings from Poland.
    Pozdrowienia z Polski. :)

    • @zellerautomationandplc
      @zellerautomationandplc  Рік тому

      Thank you very much for your appreciation. It is always nice to see that people like my videos.

  • @sekiyamaeifer2103
    @sekiyamaeifer2103 2 роки тому +1

    Wonderful! Best regards from Japan. 素晴らしい!日本より敬具。

  • @wiktorbachorz8540
    @wiktorbachorz8540 Рік тому

    jesteś gitem ziomuś, kc cb

  • @rajeshsain3591
    @rajeshsain3591 2 місяці тому

    Hello .. it’s very helpful.. thanks for sharing 🙏 .. I’m facing an issue as same plc and hmi like that HMI screen all tabs offline/ Hide during running. After 10 second as same hmi tabs coming on screen and working fine.Can you suggest me how to fix this issue?

    • @zellerautomationandplc
      @zellerautomationandplc  2 місяці тому

      Hello, depending on your programming some item only appear when communication is established. Please make sure your communication is steady. If you still encounter problems you are welcome to me an email for further communication. gerd.zeller@zeller-presscontrol.com

  • @hathaichanoksuksutthi4729
    @hathaichanoksuksutthi4729 3 місяці тому

    Can I communicate through the ethernet port bluid in which is the cc link ie field communication protocol?

    • @zellerautomationandplc
      @zellerautomationandplc  3 місяці тому

      Hi, thank you for your question. yes you can. I will be posting a video shortly

  • @juanarellano8438
    @juanarellano8438 Рік тому

    Hola, que version de gt designer tienes?

  • @user-bw7wp9ob1p
    @user-bw7wp9ob1p Рік тому

    Gs2110w-d-n can't support gtd3 can you help me thank sir.

    • @zellerautomationandplc
      @zellerautomationandplc  Рік тому

      What Version GT Designer are you using? Maybe you are using a version which is too old. Then you can not select the GS…If you got your software registered at the mitsubishi site, you can run an upgrade.

  • @thurabdeen5779
    @thurabdeen5779 Рік тому

    Need this software sir