Gas Training - Boiler Fault Finding - No Heat / No Hot Water Viva Training Academy Roy Fugler

Поділитися
Вставка
  • Опубліковано 3 жов 2024

КОМЕНТАРІ • 50

  • @avnishkumar9118
    @avnishkumar9118 3 роки тому +3

    Great tip for gas valve fault finding!thanks Alan and Roy!looking forward for wiring fault finding. Thanks once again guys!

  • @MrReza21azer
    @MrReza21azer 3 роки тому +2

    Love these fault finding videos. Thank you 👌

  • @ArifPolicewala
    @ArifPolicewala 7 місяців тому

    Thank you Allen and Roy. Another accurate quality video❤

  • @liamtulett8249
    @liamtulett8249 Рік тому

    These videos are really handy, well worth watching

  • @paulrossiter9567
    @paulrossiter9567 3 роки тому +1

    Loved this one 👏👏👏 brilliant work Roy from viva and Allen 👍
    Looking forward to future vids.
    Water / air / gas / electric…..didn’t know what wage was before this …..can’t earn a wage without using this format 👍

  • @kosalaperera1899
    @kosalaperera1899 2 роки тому

    Thank you Sirs, both Roy and Allen, really helpful as always. 100%.

  • @muhammadAli-kd2zp
    @muhammadAli-kd2zp 3 роки тому

    Another great informative video
    Roy and Allan 👍👍

  • @paulgray7226
    @paulgray7226 8 місяців тому

    Great video, thanks you

  • @zachrichardson4256
    @zachrichardson4256 3 роки тому +1

    brilliant video! more of these please? roy is a great teacher👌🏼

  • @veronicahart450
    @veronicahart450 3 роки тому +1

    Wonderful video

  • @jademcmillan4672
    @jademcmillan4672 Рік тому

    Great Video Guys. Keep them coming

  • @jameshawkins5280
    @jameshawkins5280 3 роки тому

    Once again another great video keep them coming its priceless m8 top men the pair of you should both be given a knighthood not forgetting mr ideal and the other chap .

  • @jasonwhittle5008
    @jasonwhittle5008 3 роки тому +1

    Great video lads 👍

  • @PlymouthSparky
    @PlymouthSparky 3 роки тому +1

    Great Alan and Roy. Great video, hope to be up with you guys this year for some top training.

  • @richardhodgson7443
    @richardhodgson7443 3 роки тому +1

    Very informative thank you 🙏

  • @plumbingwithbigphil6697
    @plumbingwithbigphil6697 3 роки тому +1

    🔝 rewatching this later. Quality

  • @rayc1503
    @rayc1503 3 роки тому +1

    You guys are Gold, really useful information team 👍.

  • @manjsingh6500
    @manjsingh6500 3 роки тому

    Great. Video. Top man Roy

  • @lukehodges4511
    @lukehodges4511 3 роки тому +1

    Good stuff

  • @plumbertime
    @plumbertime 3 роки тому +3

    Back voltage on a Worcester who’d of thought it! 😂
    Lovely job. What affects the air integrity test. Obviously seals ect but hear height can reduce the oxygen level
    Just to add I’m pretty good at my job but always looking for tips like any half decent engineer would be.
    I’m sure lots of experienced guys watch your stuff!

  • @kuldipkaurkalsi923
    @kuldipkaurkalsi923 2 роки тому

    Good information

  • @michaelorourke3997
    @michaelorourke3997 3 роки тому +2

    Terrific video as always. Just a couple of questions, could you not have just changed the solenoid and my other question is when I change a gas valve on a Vokera I have to adjust the gas valve in high and low fire but not here? Thanks

    • @royfugler9971
      @royfugler9971 3 роки тому +1

      Hi Michael,
      Thanks for the feedback.
      Unfortunately the solenoid isn't available as a spare part, Worcester gas valve comes factory set, so just a case of checking to make sure it's within tolerance. Baxi use a similar SIT valve and they need adjusting the same as Vokera.

    • @michaelorourke3997
      @michaelorourke3997 3 роки тому

      @@royfugler9971 thanks Roy.

  • @stephenwilliams1854
    @stephenwilliams1854 2 роки тому

    Could you do a video on how to wire up a regular (heat only) boiler with pump overrun when replacing an older boiler without pump overrun with a newer condensing boiler.

  • @Benji-gq9gx
    @Benji-gq9gx 21 годину тому

    After replacing the gas valve you could tightness test and this would show you your inlet connection to valve is sealed and tight but this wouldn't work on the outlet as valve would be shut?
    Is that correct?
    If so is ldf the only way to check the outlet connection on gas valve?

  • @Stevenb77
    @Stevenb77 3 роки тому +1

    On a couple services for Worcester greenstar boilers, after I turn the gas off to check the flame failure device. An fo 238 internal error code comes on the boiler screen. To my understanding a new gas valve is required after some check, how can turning the gas off break the gas valve?

  • @sudhiradhikari19
    @sudhiradhikari19 2 роки тому

    Hi Alan, at last, Roy said he will do video on wiring unvented cylinder and s plan, is there video done for it, if there is can you please put me the link.

  • @brubeker12
    @brubeker12 Рік тому

    My worcester bosch system boiler keeps dropping out ,it will, reboot using the manual dial control but what should I boiler engineer be checking

  • @sentemir3183
    @sentemir3183 3 роки тому +1

    👏👏👏👏👏

  • @davidb2464
    @davidb2464 3 роки тому

    Hello Roy, Excellent vid, where did you get those gas connection plugs on your hose, they look great?

  • @mikerussell1765
    @mikerussell1765 2 роки тому

    Hi Roy I've had a fault come up on my baxi compact 163 can't find what it is any idea's plz

  • @TomPalacki
    @TomPalacki 3 роки тому +1

    👍

  • @PlatinumEmergency
    @PlatinumEmergency 3 роки тому

    Where did you guys get the solid P1 connector for your gas analyser please??

  • @WEYHARRY1
    @WEYHARRY1 2 роки тому

    What is the extension called on your manometer

  • @neilbirkett835
    @neilbirkett835 3 роки тому

    I'm sure just seen roy in whitby,wasn't sure, or would av bought u a few beers buddy.

  • @Noname-k5o1n
    @Noname-k5o1n 2 роки тому

    What would you charge the customer for such a job in the real world?

  • @brethren4life152
    @brethren4life152 8 місяців тому

    baxi duo-tec still the best boiler.

  • @ElTelBaby
    @ElTelBaby 3 роки тому +2

    ROFL The thumb nail kind'a gave it away...
    WAGE =
    Water
    Air
    Gas
    Electric

  • @alondon9421
    @alondon9421 3 роки тому +1

    Is no drop after ignition not enough reason to proof gas valve need replacing ? Or testing solenoid is crucial as well on this case ?

    • @kevincranfield5235
      @kevincranfield5235 3 роки тому

      Not at all, you could have a faulty wiring harness and by assuming it’s the valve will make you look foolish.

    • @alondon9421
      @alondon9421 3 роки тому +1

      @@kevincranfield5235 so basically testing by multimeter is just checking the harness too from PCB ?

    • @kevincranfield5235
      @kevincranfield5235 3 роки тому

      A blocked condensate trap backing up into the sump will cause resistance on the fan, which in turn cannot lift the valve seating and therefore no drop on the gauge. Never never assume without proper testing.

  • @TheDickPuller
    @TheDickPuller 3 роки тому

    Can you do a video on PWM & the use of an oscilloscope please👍👍👍
    Get that Whooshitter Botch on the grass, pile of shite!!

    • @daveelder870
      @daveelder870 Місяць тому

      you always get one !

    • @TheDickPuller
      @TheDickPuller Місяць тому

      @@daveelder870 I can assure you son, I’m far from the only one, in the Trade, that KNOWS, Worcester boilers are 💩