How to test a Generac stepper motor the correct way. For Overspeed and Underspeed Faults.

Поділитися
Вставка
  • Опубліковано 10 вер 2024
  • Learn how to test a Generac stepper motor. A faulty stepper motor is the main cause of Generac alarm error code faults such as Overspeed (E-code 1200, E-code 1205), Underspeed (E-code 1600, E-code 1603), Stepper Overcurrent (E-code 2399) faults.
    Link for a new Generac stepper motor:
    - Stepper Controller Assembly Stepping Stepper Motor for Generac 0L3090 0L6388 0L6775 0J7782 0L6793 0L6355 0K4649 0J9743 0J9894 0L5765 8KW-22KW: amzn.to/4bPLJOX
    Please Note: Always refer to the generator owner's manual for specific maintenance/repair information.
    Follow me on social media:
    IG: ...
    Tiktok: vm.tiktok.com/...
    Thank you for your support!
    #Generac #steppermotor #test #faulty #diy #guardian #HSB #overspeed #underspeed #1200 #1205 #1600 #1603 #2399 #error #code #alarm #fault

КОМЕНТАРІ • 14

  • @romansroad777
    @romansroad777 3 місяці тому +1

    My guardian 22 KW unit just threw a 2399 code.
    So I will be checking the stepper in the morning.
    Thank you so much for a simple easy to understand video even to a layman such as myself.
    Take care, have a great day sir.

    • @tacticalpowerpro
      @tacticalpowerpro  3 місяці тому +1

      Thank you for watching my video. This week I checked a Guardian generator with the same 2399 code that came up after the owner did maintenance on it. While troubleshooting I found the spark plugs were swapped with the wrong plugs. Instead of the BPR6HS plugs they used the B6HS which has a shorter tip. I’m still wondering how that throws a stepper overload 2399 but once I swapped the spark plugs for the right size the fault never showed up and the generator ran under load without issues.

  • @luis5558
    @luis5558 Місяць тому +1

    I have a Generac 22kw and it as a code 1603

    • @tacticalpowerpro
      @tacticalpowerpro  Місяць тому +1

      Hi, error code 1603 is the underspeed fault. This code appears when the engine never comes up to 3600 rpm. I will recommend checking the fuel selection and fuel supply.

  • @radiolandia
    @radiolandia 3 місяці тому +1

    Thank you for your video. I have a Generac Guardian 17 Kw with the Nexus Controller that when I turn it on, the rpm ranges between approximately 3550 and 3650. I look at the output shaft of the stepper motor and small periodic movements are noticed. I'm thinking that the stepper motor is damaged. In 12 years of use of this generator, this is the first time that this failure has occurred. Thanks again

    • @tacticalpowerpro
      @tacticalpowerpro  3 місяці тому

      Thank you for watching my video and I’m glad my video was helpful. The stepper motor should move back and forward prior to start. I have another video in the channel where I’m troubleshooting a generac guardian with the 1205 error code and I show how the stepper motor should work, test (again) and how to replace.

  • @LouisS-cs7bh
    @LouisS-cs7bh 4 місяці тому +2

    What is the purpose for the steeper motor?

    • @tacticalpowerpro
      @tacticalpowerpro  4 місяці тому +1

      Thank you for you comment! Good question, the stepper motor opens and closes the throttle of the Generac generator. It receives the signal from the control panel to open and close as needed to keep the right air flow to maintain the engine at 3600rpm.

    • @LouisS-cs7bh
      @LouisS-cs7bh 4 місяці тому +1

      Thanks

    • @tacticalpowerpro
      @tacticalpowerpro  4 місяці тому

      You're welcome, I'm here to help.

  • @menecogonzalez363
    @menecogonzalez363 2 місяці тому +1

    Compa, cm puedo comunicarme con tigo? Es que compré un generador honda 2200 usado y ya le limpié el tanque el carburador le cambié el spark y sigue cn problemas, algún número para combinarme con tigo?? La consulta no sería de gratis $$

    • @tacticalpowerpro
      @tacticalpowerpro  2 місяці тому

      Saludos! Si te unes a una de mis membresías en el canal recibirás mi numero de WhatsApp donde te puedes comunicar directamente conmigo para consultas o apoyo durante una reparación.

    • @menecogonzalez363
      @menecogonzalez363 2 місяці тому +1

      @@tacticalpowerpro dónde me puedo inscribir ?

    • @tacticalpowerpro
      @tacticalpowerpro  2 місяці тому

      @@menecogonzalez363 entras a mi pagina de UA-cam y al lado del botón de suscríbete hay un botón para unirse a las membresias. Me dejas saber si te topas con algún problema.