Turbine fire Protection-1&2 | Fire protection logic | Turbine Protection | Thermal power plant

Поділитися
Вставка
  • Опубліковано 26 жов 2024
  • Turbine fire Protection-1&2 | Fire protection logic | Turbine Protection | Thermal power plant
    • Actions after Boiler t...
    / @kpatelbla
    Power Plant technical Pratyush

КОМЕНТАРІ • 20

  • @manohardhaker423
    @manohardhaker423 4 місяці тому

    Very good topic.....also nice explan....

  • @deepakkewat3547
    @deepakkewat3547 2 місяці тому +1

    Nice sir

  • @ujjalsonamukhi
    @ujjalsonamukhi 11 місяців тому +1

    Thanks 🙏

  • @deepakkewat3547
    @deepakkewat3547 11 місяців тому +1

    Nice sir,

  • @BhaskarGore-q4d
    @BhaskarGore-q4d 11 місяців тому +2

    Well explain sir....

    • @kpatelbla
      @kpatelbla  11 місяців тому

      Thanks for watching

  • @Suman_shukla
    @Suman_shukla 8 місяців тому +1

    Thank you so much sir 😊

  • @0503manoj
    @0503manoj 9 місяців тому +2

    Sir
    Agar fire protection act hoga to HP/LP BYPASS valve open hoga ya nahi...?
    Please explain sir

    • @kpatelbla
      @kpatelbla  9 місяців тому

      Actually in case of fire protection operated vacuum breaker open in protection so HP & LP Bypass must be closed means both not open in this case.

    • @0503manoj
      @0503manoj 9 місяців тому

      Thanks you sir

    • @0503manoj
      @0503manoj 9 місяців тому +1

      Sir
      It will be followed in both conditions. As Fire protection 1 and fire protection 2
      Means
      If both protection acted then HP/LP by pass valve will be fast open ...?

  • @ashutoshkumarpandey3099
    @ashutoshkumarpandey3099 11 місяців тому +1

    Sir, Please make a video for Mill fire , Aph fire and bunker fire 🔥

  • @aegon5399
    @aegon5399 2 місяці тому +1

    Sir ji Agar HPCF line me leakage Hoti hai ya fir HPCF pump me leakage hoti hai To FIRE PROTECTION-1 Daba sakte hai kya??
    FP-2 me MOT LEVEL pe Interlock hai but
    FP-1 Me aisa Koi logic ni hai To kya HPCF Fluid ko behne de Ya fir FP-1 Daba sakte hai??

  • @nitinbhonsle9534
    @nitinbhonsle9534 8 місяців тому +1

    Sir.... What about operation of vacuum breaker in channel 1 and 2 for its opening?

    • @kpatelbla
      @kpatelbla  8 місяців тому

      In case of FP 1 vacuum breaker remains closed but in case of fire protection 2 operated vacuum breaker protection open as total lube oil system protection stopped so it is necessary to costing down down turbine as soon as possible.

  • @motive0507
    @motive0507 11 місяців тому +1

    Sir, I have doubt please clarify
    Coal burner elevations like A,B,C,....J and oil burner elevations like AB,CD,...
    sir,if we want to give some burner tilt like 30%,then tilt will occur in all coal and oil elevations or can we give the tilt to particular oil or coal elevation?

    • @kpatelbla
      @kpatelbla  11 місяців тому

      It is always common command to all elevations coal and oil burner, never for any individual burner otherwise it would create flame failure due to disturbance of fire ball consequently disturbance in flame intensity.

  • @sandeepgajbhiye4913
    @sandeepgajbhiye4913 8 місяців тому +1

    Why DC EOP, DC JOP ON in fire prot 2. in case of actual fire because fire may become heavy in case of oil supply

    • @kpatelbla
      @kpatelbla  8 місяців тому

      Exectly Total oil system protection off in case of FP 2