Sauna Electrical Installation for Huum Heater and Lighting

Поділитися
Вставка

КОМЕНТАРІ • 59

  • @Shepherd174
    @Shepherd174 Місяць тому +1

    Thank you! The instructions with this sauna were a nightmare this made life so easy

    • @handyhomerepairs
      @handyhomerepairs  Місяць тому

      You are welcome. I know what you mean, I spent a long time looking for examples or other videos and everything was limited.

  • @guidojones100
    @guidojones100 11 місяців тому +1

    Your video and wiring details (in the comments section) helped me out. Thank you.

    • @handyhomerepairs
      @handyhomerepairs  11 місяців тому

      @guidojones100 glad to hear! I know there was limited info out there when I was building so I’m glad to contribute

  • @handyhomerepairs
    @handyhomerepairs  Рік тому

    The wiring was completed in only a few hours. I already purchased the circuit breaker and wiring so it was ready once the Huum heater arrived. The high temperature conduit I had to order a few weeks in advance. It was difficult to find (at a reasonable price), so I had to order off eBay. It was still $150 U.S. and I only needed 2 feet. Conduit is Liquid-Tuff Hi-Low Temperature LFMC.

    • @livinglifeasa16handicapfor27
      @livinglifeasa16handicapfor27 Рік тому

      Do you think teck cable would have been sufficient?

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @@livinglifeasa16handicapfor27 I'm not an electrician, so not sure. I read that you need a sealed box and the conduit also needs to be waterproof. In addition, since there are high temperatures you need a high temp conduit. Most of the conduit I looked at did not meet both of these conditions. I wanted to be as safe as possible since people, 240v, and wet conditions seemed like a risky situation

  • @captainsgold9903
    @captainsgold9903 5 місяців тому +1

    This was a great video. Question: is the high temperature wire you used, copper or tinned copper? Does the ground have to be high temp as well or just 10awg bare copper? I blew my circuit breaker after hookup

    • @handyhomerepairs
      @handyhomerepairs  5 місяців тому

      @captainsgold9903 I’m not an electrician but I bought mine from a company called Wire & Cable Your Way. Search for High Temperature Wire. It’s stranded and says it works in wet or dry locations. Says nickel coated. It handles very high amps for the gauge because it has so many strands. Technically the ground should only be needed in an emergency but I was already installing the wire so I used the same for all 3 and made sure I could securely connect it to the frame.

  • @themorenogroupkc
    @themorenogroupkc 8 місяців тому

    Thanks for the video. Very helpful! HUUM's install manual is rather simplistic and doesn't really discuss the mounting of the wire/processor box. How did you mount it to the wall?

    • @handyhomerepairs
      @handyhomerepairs  8 місяців тому

      I had to mount to the inside of the exterior wall in the cabana. I just attached some 2x3 furring strips to the wall and some regular screws. It’s not heavy. The multiple pits of heavy gauge wire is secured underneath the box so everything has plenty of strength

  • @NonStopNeal
    @NonStopNeal Рік тому +1

    HI mate great videos and sauna build. DO you have a photo or example of how you wired up the heater? did you just leave the earth off? Thanks.

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @NonStopNeal I got ahead of myself and installed all the rocks and forgot to capture the wiring. It was basic 240 volt install though. There were 2 leads, one for each of the 120v legs. The ground was definitely installed with the screw to the frame since everything is metal, there is moisture, and people can easily touch. The circuit breaker is arc and ground fault. I read some places that sauna heaters can trip ground fault but we have used the sauna at least 30 times now and have never had an issue.

    • @NonStopNeal
      @NonStopNeal Рік тому +1

      @@handyhomerepairs Thanks for this, I have the 6kw Drop. Looks like i need a 5 core wiring for mine.

  • @jamalothmanRN
    @jamalothmanRN Рік тому +1

    What kind of cable did you use between the control panel and the heater? I was told I will need a heat resistant cable, but couldn't find it except as a single conductor. Please share link if you purchased it online. Thank you

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @jamalothmanRN I used standard cable run to the heater but terminated it in a weatherproof sealed box on the inside of the sauna. I assumed that there was no heat radiating through the wall, foil barrier, and insulation. But, from the junction box inside the sauna, I then splice to high temperature appliance wire. The run from the box to the heater was also inside high temperature sealed conduit. I’m sure someone else will correct me if I’m incorrect. This was the wire I used.
      www.wireandcableyourway.com/12-awg-tggt-wire-high-temperature-wire-250-c-ul-5256-5196

  • @user-bt2gv2qu3g
    @user-bt2gv2qu3g 11 місяців тому +1

    Did you wire in a light to the huum control panel?

    • @handyhomerepairs
      @handyhomerepairs  11 місяців тому

      @user-bt2gv2qu3g no. I manually wired a light to an exterior switch. I didn’t want to have to control light via huum controller

  • @brianjones1968
    @brianjones1968 Рік тому +1

    Excellent video. Can you advise of the name of the wire used from the junction box to the heater and where you were able to purchase it?

    • @handyhomerepairs
      @handyhomerepairs  Рік тому +1

      It is just basic wire you can get from large home center stores. Usually called NM or romex. The thickness or gauge of the wire depends on how much electricity the breaker allows. My heater is 6000 watt on a 30 amp breaker, so it needed 10 gauge wire. This is North America wire naming convention. The heater is 240 volt so it needs 2 electrical conductors and 1 ground. Its called 10/2 with ground (10 gauge, 2 conductor). It is behind the protector wall so didn’t need anything special. The wire runs into a water tight box. From that point to the heater required special wire that can handle high heat and not be affected by water. Inside the sauna it runs through a high temperature resistant and water tight conduit

    • @col2007
      @col2007 Рік тому

      @@handyhomerepairs What water tight box did you use? Having a hard time finding something at a big box.

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @@col2007 my Huum came with that water tight box. You can buy similar ones on Amazon. If you look in the description of my other video “Stream Music Alexa Echo link…” there is a link to Outdoor protective box. That is what I use for outdoor to protect the Alexa. You can start there and find the size you need.

  • @tinafernandez2876
    @tinafernandez2876 Рік тому +1

    I received an extra extension box. I did not see you connect one to your system. Is a extra one necessary? Extension box...

    • @handyhomerepairs
      @handyhomerepairs  Рік тому +1

      @tinafernandez2876 I didn’t get any with mine. The control panel for the temperature dial just surfaced mounted. The thermostat gauge also surface mounted. I added an outlet box for the wire connection for the door sensor just so I could adjust it if needed. The only box I received was the main unit for all of the wiring. The wiring for the heater element in the sauna required a waterproof box so I bought that myself as well along with all the water tight connections.

  • @MichaelKulsrud
    @MichaelKulsrud Рік тому +1

    Hi do you have any extra of the high temp conduit you'd be willing to sell? I am installing a 6kw Cliff and need a couple feet.

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      I don’t sorry. I sold what I had left on eBay. I bought mine on zoro. I searched around on several different sites and finally found there. Some electrical shops also had it but they were either commercial only or shipping was too much. I think I also had to wait a couple weeks for it to be in stock but finally got what I needed. This is what I ordered. Liquid-Tight Conduit,3/4 In x 25 ft,Gray

  • @karahaskell4269
    @karahaskell4269 Рік тому +2

    Thanks for the great video! Very helpful. I have the 9kW 50 amp breaker and am pretty lost on what wire to use from the main circuit breaker to the main module as well as from main module to the heater. Any advice? Thanks again for sharing!

    • @handyhomerepairs
      @handyhomerepairs  Рік тому +2

      @karahaskell your 50amp circuit breaker is correct for 9kw heater. 50 amp require 6 gauge wire (assuming you are in north America). You will want 6/3 for circuit breaker to control unit, which is 6 gauge with red (hot), black (hot), white (neutral), bare (ground). The 120v white is only needed for lights and some accessories but might as well run in case of future upgrades. The heater doesn't need neutral so you can continue the hot red/black and ground to the heater with 6/2 wire. All of the other connections (temperature, door sensor, remote, etc) are low voltage.

    • @karahaskell4269
      @karahaskell4269 Рік тому +2

      @@handyhomerepairs Thank you so much! Really enjoying your whole sauna series. Great information in a general void!

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      Thanks so much. It was great fun to build and I was in the same situation having to piece information together as I built or just guess sometimes if I couldn’t find help.

  • @JohnConnor-2029
    @JohnConnor-2029 5 місяців тому +1

    Hi man! What kind of cable did you use for the door sensor?

    • @handyhomerepairs
      @handyhomerepairs  5 місяців тому +1

      @JohnConnor-2029 the wire they provided in the kit was not long enough so I had to replace it. The problem was the wire was marked in mm since it is from Europe. I found an online converter to see what the AWG size was compared to mm2 equivalent. Probably overkill since it is low voltage. Ended up with the multi wire cable like is used for a thermostat. Only need two wires but telephone wire gauge was too small

    • @JohnConnor-2029
      @JohnConnor-2029 5 місяців тому

      @@handyhomerepairs I also purchased the stove but like you I have the same problem and I don't know what the hell wire to use to extend it to the control unit. Thank you so much for your advice, my video will also be online soon.

  • @marcjohnson6618
    @marcjohnson6618 Рік тому +2

    Does the HUUM come with a wiring diagram/instructions?

    • @handyhomerepairs
      @handyhomerepairs  Рік тому +1

      Yes. All the connections are labeled in the manual for the control box. Electrical wiring is basic, 2 hots, neutral, and ground into box (only need neutral if controlling lighting). 2 hots and ground out to the heater. I forgot to include in video because I got excited putting in the rocks but connecting the heater part was simple. The ground connected to the frame and the 2 hot 120 volt legs were connected to terminals. No electronics in the heater

    • @marcjohnson6618
      @marcjohnson6618 Рік тому +1

      @@handyhomerepairs What size wire did you use? 10/3?

    • @handyhomerepairs
      @handyhomerepairs  Рік тому +1

      @@marcjohnson6618 yep exactly. 30 amp breaker. Mine is 4.5 kw so the 19 amps is over the 80% calculation for a constant load on a 20 amp circuit.

    • @marcjohnson6618
      @marcjohnson6618 Рік тому +1

      Sounds good. Thanks for the info and the video. It’s the only one I’ve seen about installing a HUUM. Mine should be here in a couple weeks so this helps a lot.

  • @blakeb4399
    @blakeb4399 6 місяців тому +1

    Any issues woth the lighting circut? Installing and there is no power to the lighting circuit.

    • @handyhomerepairs
      @handyhomerepairs  6 місяців тому +1

      @blakeb4399 I did not use the lighting circuit from the control center. I wanted to control it with a regular switch / dimmer so I ran a separate line.
      Did you run 4 conductors to the control center? The light needs the neutral white wire.

    • @blakeb4399
      @blakeb4399 6 місяців тому +2

      @@handyhomerepairs yes metered everything today I believe the control center is faulty contacting the company tomorrow

    • @handyhomerepairs
      @handyhomerepairs  6 місяців тому +1

      Figured you did it right. Just checking. It’s fairly simple, so sounds like control panel issue

    • @blakeb4399
      @blakeb4399 6 місяців тому

      @@handyhomerepairs the homeowner had to turn the circuit on in the app who would have thought.

    • @handyhomerepairs
      @handyhomerepairs  5 місяців тому

      Oh wow. That is strange. I don’t even have that option in my app.

  • @chrismarino9104
    @chrismarino9104 Рік тому +1

    Can you just put a jumper on the door sensor and not install it?

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @chrismarino9104 yes, I believe I saw one of the other commenters mentioned that they did that. I didn’t want the heater running with the door accidentally left open and heating the outer room or running constantly so I installed the sensor

  • @TCB2023.
    @TCB2023. Рік тому +1

    I cant turn it on if anyone has ideas im all ears. I tun the breaker on and I hear a click in the controler and thats it no display nada

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @TCB2023. You turned it on so the control panel with LCD is working? If you hear the click, then the relay is engaged and there should be power to the heater. Check if you are getting voltage on the “output” to the heater and maybe one of the wires or ground is not connected on the heater element? Oh you said no display? The click should not occur until the request to turn on from controller is given. Check if you have both 120v wires connected and the ground. I don’t think the white/neutral is technically needed to power the until (according to them manual it’s only for auxiliary lighting)

    • @TCB2023.
      @TCB2023. Рік тому

      @@handyhomerepairs No LCD display. Click happens when I turn on the breaker.
      Its 208v. HUUM said it should still work just 20% less output. Haven't heard back from them other than that.
      We're in Hawaii.
      Appreciate your help

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @@TCB2023. is this 208 volt 3-phase? If so, that won’t work because the sine wave phases of this system are different than residential single phase. I see Hawaii offers 208 volt single phase to residential so maybe the Huum system is having issues with the lower voltage if that is the case.

  • @peterkozhenevsky9500
    @peterkozhenevsky9500 Рік тому +2

    You can skip door sensors. Just put a jumper wire.

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      I see. That makes sense. I have careless people in house (not naming names) that may leave door open with hearing running. Mine also was wifi control as well, so would be a bad combination with remote start

    • @gonzo1274
      @gonzo1274 Рік тому +2

      I’ve been waiting for a video like this! I just put together a barrel sauna and have the drop 6. I’ve been thinking how I’d do the door sensor and never thought about doing the jumper. I’m not worried about the door issue. This is great!

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @@gonzo1274 Glad I could indirectly help lol

    • @gonzo1274
      @gonzo1274 Рік тому

      Haha, no your video helped way more then just the door. I’ve been looking for months for a video on the whole wiring setup. The jumper was just a bonus. Just one less thing to worry about since mine is outside.

    • @handyhomerepairs
      @handyhomerepairs  Рік тому

      @@gonzo1274 I know right? I spent forever searching for electrical help and it’s a dead zone. I spent weeks trying to figure the water and heat resistance conduit for the electrical. Finally found on eBay and had to buy 25 feet to use 2 lol