    Awesome video. Thank you very much Martin. We are anchored out in Georgian Bay and woke up to make my coffe and charge the house batteries. My Honda 2000i had the dreaded no AC,ughhh. I went through your testing procedure and never guess what I found. Yep, my white AC output wire has broken right at the connector. Exact same issue. Jammed the wire back in the connector and put a little dab of JB weld to hold it in place. Just a quick fix to get power, will replace the connector when back home. Thanks again Martin, you're a life safer.

  • @tomshaw9846
    @tomshaw9846 19 днів тому

    Hi. Any idea what the part number is for the replacement loom or the connector size. Got exactly the same problem

  • @eegg6954
    @eegg6954 3 роки тому +2

    Nice stuff and good advice in your notes. You are one out of 100 guys who post videos that know how to use a meter and how to troubleshoot. Lots of bad advice on UA-cam. You it it on the head about how these generators function. Get the engine running right, check your motor speed and your wiring. That will solve 95% of the problems. I wonder how many inverters are replaced needlessly. Thanks for a great video. Also, if you do lots of this work, sets of connector pins and alligator clips are made for meters to fit different size jacks.

  • @tinantoddm
    @tinantoddm 3 місяці тому

    Thank you for a great video, sorry for the long post. I have an unusual issue with my eu2000i. The generator starts fine but I get no power to the outlets and the green led doesn’t light. When I was testing your troubleshooting options by checking the voltage of the 5 wire connector I was only getting 190v a/c, not 225v though I was getting 10v from the pink/gray. The weird thing is, when I plugged the 5 wire connector back together while the engine was running, the green led went on and the outlets then had 126 volts and it worked perfectly to power my tools. After I shut off the generator and restarted it the green led was out again and I had no power until I disconnected the 5 wire connector and replugged it back together which worked again to turn on the green led and have power to the outlets again. This work-around only works if the eco switch is on. If the eco switch is off, and I unplug and replug the 5 wire connector while the motor runs, I get no green led light one no power at the outlets. Is it possibly a capacitor issue? When eco mode is on, and I unplug and replug the connector, the motor slows for a couple of seconds and then regains its speed. Also, after I unplug and replug the connector in eco mode and have power, I am able to switch between eco mode and no eco mode and the outlets don’t lose power and the meter show a consistent 126v. I converted my eu2000i companion to propane when I purchased it 15 years ago and It’s worked perfectly up until a few weeks ago.

  • @noviceytp5005
    @noviceytp5005 23 дні тому

    I feel your joy when you finaiiy fix something and it works

  • @Slytheslayer
    @Slytheslayer 3 роки тому +2

    Thanks for all the detail. I’m having a similar problem with a ryobi 2200. Your video was the only one I could find that went into detail about anything.

  • @loosemink
    @loosemink Рік тому

    Mine is having the same problem, no power coming out.
    I'm gonna go through what you have shown.
    Thank you for doing this video ❤️

  • @bcy42
    @bcy42 Рік тому +1

    Hey Martin, I just changed my spark plug, carbeurater (old one had a broken choke lever), and air filters. When i put it back together, it will only idle at a very low RPM. No power from AC outlets. Any advice what I should check for? From looking, this is not a very common problem.

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  Рік тому +1

      Sounds like the linkage to the idle control solenoid is not hooked up right. or the control solenoid is not getting signal to raise the idle. Try disconnecting the linkage to the throttle and manually increase that throttle and see if you get power. If you get power, focus on the idle control solenoid. They do go bad.

  • @bmwlane8834
    @bmwlane8834 4 роки тому +2

    Martin, great video. Nice find...I get the excitement...I'm a shadetree guy....It's a thrill to slam dunk a fix like did. Take care.

  • @piccadillycircus9416
    @piccadillycircus9416 3 місяці тому

    Hi Martin. Thnx for educating community, it is weary hard to find any DIY info on these generators. I’m having issue where there are no lights at all , generator is running rough and only has 16v DC output where 12v should be . Also checked the AC output from white , blue and red whirring and it does produce 220-260v depending from RPM’s , do you have any advice how to proceed from here ?

  • @manuelmach86
    @manuelmach86 Рік тому

    I bought the 2200 but i should’ve got the companion because of the 30amp plug for my rv. Is there a kit to change out the plate containing both plugs? A plug and play kit that contains a 30 amp plug? Essentially turning my 2200 into a companion?

  • @dieseldawg7132
    @dieseldawg7132 6 місяців тому

    I have a question I recently bought a used home eu2000i and I cleaned out the fuel tank and the carburetor and the internals…. The machine runs very good my only issue is that well it starts wanting to cut out around 1600 watts and then it drops and tries to pick up watts and drops again it never shows overload….. the green light does seem to momentarily go out….. lets say I kept it at 1300 watts I would have no issue take up a notch and it starts to stumble….

    • @dieseldawg7132
      @dieseldawg7132 6 місяців тому

      Also my circuit breaker/ reset switch never pops out would it only pop out on a short circuit or would it also blow on an overload ?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  4 місяці тому

      Sounds like it could be several things related to a heavy load. Possible that the carb is not getting enough fuel delivered to it. Check flow from the hose going into the carb. It might also be a ignition coil breaking down under load. Hard to diagnose this issue. I would try everything else and then replace the coil. Good luck,

    • @dieseldawg7132
      @dieseldawg7132 4 місяці тому +1

      @@MartinMetregerTipsandTricks hey thanks for your reply after messing around with the generator I realized two things one the spark plug was part of the issue and then also I had to clean the heck out the carb replace all seals after and it worked like a champ

  • @prepperboss
    @prepperboss 10 місяців тому

    I have an older Predator 2500 inverter that runs beautifully but doesn't power the 110v outlet. I replaced the outlet with a household outlet and it worked on a small appliance. i started it later and it didn't work again. Any suggestions?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  10 місяців тому

      Sounds like you might have a broken wire leading to the outlet. Try pulling on the wire in different spots to see if it wiggles or comes apart. Good luck

    • @prepperboss
      @prepperboss 10 місяців тому +1

      @@MartinMetregerTipsandTricks thanks I'll give it a try.

  • @stevenpetty3747
    @stevenpetty3747 2 місяці тому

    Very informative and helpful broke down a lot of questions I had. Thanks

  • @raynic1173
    @raynic1173 Рік тому +1

    Thanks, I have a dead one also, hoping to figure it out. Thanks for the info...

  • @NJMS17000
    @NJMS17000 7 місяців тому

    Hello, mu honda eu1000i 220v 50hz has a delay to start ac output. When this problem started, when i started the denerator i had to put eco throttle button on rabit to start to generate ac power inmediately. And now after i start, i have to wait around 10 - 30 minutes to start to generate ac.

  • @Theistliecatcher
    @Theistliecatcher Рік тому +1

    Same issue on my brand spanking new eu2200i. I got it yesterday. Kept flooding i paid out of pocket for the fix. Now i get home, have green light, no power. Tested as a ground reverse. I dont know how to fix it so im returning it

  • @Eeprom986
    @Eeprom986 2 роки тому +1

    Nice work
    I have the same Honda, have a problem with 12 volts DC port I found 24 Volts
    Any suggestions to resolve this problem?

  • @jakefalk6350
    @jakefalk6350 2 роки тому

    Great video I have a ex 650
    Honda suitecase and the voltage is reading very high what do you think this could be

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  2 роки тому +1

      Check this video out at 7:10 for proper governor adjust. ua-cam.com/video/IgmSk2-vWNc/v-deo.html
      There is also a screw to adjust the speed of the engine which will adjust voltage and hz. You need a meter that will read hz which should be set to 60 in the USA. Not sure what the settings would be in Europe. Good luck!

  • @meginmurphy9685
    @meginmurphy9685 4 роки тому +2

    Thank you! We are going to try this over the weekend. Appreciate the great explanations!

  • @joshuahall9809
    @joshuahall9809 Рік тому

    I bought a new fuse and it says line & Load but old one doesnt say anything on it please help.

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  11 місяців тому

      That is strange that the fuse is directional. Most are not. Line to inverter and load to outlet. Hope that helps.

  • @fool4wheelin
    @fool4wheelin 2 роки тому

    Nice video, I had the same problem with mine, broken connector terminal on the white wire. Must be a common issue with these units.
    How did you fix yours, did you solder the terminal back together? I’ve been trying to find a replacement terminal with no luck.

  • @carlosderegil8674
    @carlosderegil8674 3 роки тому

    Hi Martín , my eu20i is not giving me the 2000 watts , my other one is fine so I’ve been swapping everything to the bad one and does the same so it’s not the carb or the spark or the other components . I met be thinking about the fuel pump met not be sending the right fuel pressure, I already did everything, if I swap the whole carburetor and didn’t work what ekes could it be ?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому +1

      Does the generator run but no electricity or is it a no start condition? No start, I would say check for spark. If you have a good spark at the spark plug, try squirting flammable brake clean or carb clean in the carb and try to start it. if it start for a moment and dies, you might have a bad fuel pump or blocked line. check for kinks in the fuel hose. Another thing to check is smell the gas. Maybe the gas is so old, it won't burn well or someone put diesel fuel or something else in the tank. You can check compression and make sure you get at least 90 psi. Good luck.

    • @carlosderegil8674
      @carlosderegil8674 3 роки тому

      @@MartinMetregerTipsandTricks thank you for the response , I’m in Mexico so my English may be bad . The eu20i runs well but is not giving my the juice , is not like the other one that gives me the 2000 watts entirely, when I plug a water pump it won’t make it run and goes to red or blocks it’s self , I know is not giving me the juice because the other eu20i I have it does , it gives me all the juice and I even cab run a small portable AC that starts at 1200 watts to run the compressor . The faulty eu20i is not , so I’ve tried swapping the whole carb unit from the good one to the bad one and it does the same so it’s not the carburetor , I even swap the spark plug and even placed a new spark plug and it does the same . What can it be ? The fuel pump ? Or is it the electrical components , I have no idea what can be causing that , I even tried cleaning that black screw by the carburante or that one turns it 4 times to calibrate , this plastic black screw has a tinny hole that I have cleaned already and just by placing the good carburador from the good generator I have it should give me results but it doesn’t . What I’m thinking is the fuel pump may be which is not sending the right amount of gas ?? Do you know how to access and Clean the fuel pump ? Can you help me find a tutorial for fuel pumps ? Happens that my search engines go to Spanish and in Spanish I have nothing good for tutorial on this Honda inverter model . Thanh you so much for the help . I guess you have subscribers all over the world , well you have me on the Mayan riviera and I’m glad I can follow you

  • @jacobalderton9262
    @jacobalderton9262 2 роки тому

    Can you link where you found the wiring harness

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  2 роки тому +1

      I went to a small equipment repair shop and the sold me a used harness. It was hard to find. I actually fixed my harness before I finally got a good one.

  • @AcesUpOffroad
    @AcesUpOffroad 3 роки тому

    I have a Honda generator that the green indicator light comes on, and no power at the plug ins? Any ideas?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      Hopefully you performed the test as described in the video. Closely look at the wiring behind the front panel. I found a broken terminal that caused the problem. Also, make sure the circuit breaker is not tripped. Hit the reset and check the ohms of each wire. Good luck.

  • @joseirizarry6845
    @joseirizarry6845 4 роки тому

    hi i have question, i have the same generator but nothing turns on in the front panel. i metered the long plug behind it and i get haf voltage on everything. for the 12v i get 6 for the 240 i get 120. but i notice that the rpm is very low. and also no light infront. what can it be ? thank you

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  4 роки тому

      Here are a few notes:
      If the motor is running to slow, nothing will light. You might need to look at the idle control circuit wiring or idle control motor.
      Make sure the motor is running between 4200 to 4600 RPM. You might have to manually move the throttle on the carb to increase the RPM. Voltage will increase with RPM
      Make sure you checking AC volts with your meter.

  • @johnCamden-w2s
    @johnCamden-w2s Рік тому

    Do you recall a part number for that wire? After an hour of troubleshooting your video took me right to the problem.

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  11 місяців тому

      I could not find a part number. I believe it is discontinued. Repair the wire or maybe you can find a dealer with old generator parts. Good luck.

  • @MsDave64
    @MsDave64 2 роки тому

    How about a link to the maintenance manual for the EO2000i.

  • @Wakeupdud3
    @Wakeupdud3 3 роки тому

    Hey man my eu3000is has no power output motor runs perfect it’s in great shape and I’ve looked for lose wires ground and everything checks out but I don’t know how to diagnose inverter module or power from stator

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      I don't think my video will apply to the eu3000is but it will have similarities. Look for the shop manual. I found some for sale online. With the manual, it has step by step test to determine what has failed. Keep in mind that inverters rarely fail. So test twice before buying parts. Good Luck.

  • @carlosderegil8674
    @carlosderegil8674 3 роки тому

    i have 2 honda eu20i one of them goes to red when demanding power and the other one its just fine and takes 2 seconds to power uip the AC , portable air conditioner, what is wrong with it? i already swap all the carburator and spàk plug and does the same, so i imagine it is an electriucal issue, can you help me? im at the mayan riviera in mexico

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      If both generator/inverters are the exact same, then yes you have a problem. They do make a eu2200i that has more power which can easily be mistaken as a eu2000i. If they are the same, try turning off the ECO Throttle and see if it makes a difference. Follow the test procedure within the video to make sure you don't have bad stator stator. The Idle Control Motor adjust the speed of the engine based on demand. If the Idle Control Motor is not functioning, the engine will not speed up when needed. You can try increasing the RPM by manually opening up the throttle. If the light goes green than look into replacing the Idle Control Motor. You can always try swapping parts from the good generator/inverter to isolate the issue. Good Luck,

  • @ronalddesharnais6022
    @ronalddesharnais6022 Рік тому

    What is the site you obtained the manual from?

  • @edryalvarez
    @edryalvarez 7 місяців тому

    Saludos como podria conseguir el avr de ese geneeador eu2000i

  • @scubahealer
    @scubahealer 7 днів тому

    Would have been nice if you showed how you fixed the wire

  • @juancolon3298
    @juancolon3298 3 роки тому

    Greetings ... Because the safety, protection button on a briggs stratton 2200 inverter has gone down and it stopped generating electricity ...

  • @thebull5099
    @thebull5099 3 роки тому +1

    Great job bro. I'm working on one now. The motor is running rough at idle. And I got to clean that jet under the idle screw. But the green light was on till I got it to crank

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому +3

      If the motor is running to slow, nothing will light. You might need to look at the idle control circuit wiring or idle control motor. Try manually increasing the speed of the motor to see if the green light turns on. If it does, than you might have a bad Idle Control Solenoid or wiring to it.

    • @thebull5099
      @thebull5099 3 роки тому

      @@MartinMetregerTipsandTricks im working on it for a friend. It wouldn't crank at first. I cleaned the carburetor out and it Crunk up. But the green light stayed on for about 3 sec and went off. It was running rough when green light went off. It ran good for about 4 sec

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому +1

      @@thebull5099 Focus on getting running good. Then worry about the light. You might have bad gas or water in the gas. The carb has tiny holes by the throttle plate. Use the smallest wire in a torch cleaner to push through the holes. Don't force it. Striped copper wire will work too.

    • @thebull5099
      @thebull5099 3 роки тому +1

      @@MartinMetregerTipsandTricks i got it running idle screw jet was logged. Thanks bro

  • @THEGUNSGOBOOM
    @THEGUNSGOBOOM Рік тому +2

    Thanks for the video

  • @jimdent351
    @jimdent351 4 роки тому +1

    I'd be willing to bet that even if your generator did need a new inverter then it still would have been money better spent than buying a budget generator such as the Predator. I don't need to repair my machine but your video was educational nevertheless.

  • @rafaelaquino2872
    @rafaelaquino2872 4 роки тому +2

    I call that complete happiness.

  • @doglegjake6788
    @doglegjake6788 9 місяців тому +1

    Excellent video

  • @JorgeluisTorresCabrera-z4q
    @JorgeluisTorresCabrera-z4q 8 місяців тому

    very good, thanks

  • @izzie5657
    @izzie5657 3 роки тому

    engine working prefect but no power no green light, any idea how to fix it, what is the problem please 🙂

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      Did your follow my step by step checks in the video? Start there. Also, make sure the idle is not too slow. Must run fast enough to turn on the green light.

  • @bramchabochank7489
    @bramchabochank7489 3 роки тому

    What's the reason boss, the coil doesn't exist?

  • @Madhugauranguero
    @Madhugauranguero 3 роки тому

    Hey thanks for all the info in this vid.
    Q: my output light does not come on but I do get power
    Do u know what it can be
    It works just the light don’t come on
    Thanks in advance

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      Sounds like the light itself is bad. I believe the light is integrated so you can't replace it as it is part of the module. My advice is if you are getting power, then live with it.

  • @GH-wt7ww
    @GH-wt7ww 3 роки тому

    Great Video
    Can you tell us how many hours approximately are on the generator you are working on?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому +1

      I believe over 300 hours. The light flashes 3 times when I start it up.

    • @GH-wt7ww
      @GH-wt7ww 3 роки тому +1

      @@MartinMetregerTipsandTricks
      Thank you

  • @jedzuniga8739
    @jedzuniga8739 Рік тому +1

    Great video ty

  • @juancosta2647
    @juancosta2647 2 роки тому

    hola tengo un generador igual al de tu video, es 120v. yo vivo en la argentina y la corriente es 220v. tengo alguna forma de convertirlo para 220v

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  2 роки тому

      That is a good question. I don't know enough about your electrical voltage to provide safe input. I'm sorry.

    • @juancosta2647
      @juancosta2647 2 роки тому

      @@MartinMetregerTipsandTricks hola no entiendo tu idioma, me podes responder en español

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  2 роки тому

      @@juancosta2647 Esa es una buena pregunta. No sé lo suficiente sobre su voltaje eléctrico para proporcionar una entrada segura. Lo siento.

  • @bayardtaylor2990
    @bayardtaylor2990 3 роки тому

    How much would it cost to. Replace the inverter?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      When I checked, it was over $400.

    • @bayardtaylor2990
      @bayardtaylor2990 3 роки тому +1

      @@MartinMetregerTipsandTricks ok thanks. Mine is toast. Just ordered. The Westinghouse. 2200 super. For just about the same amount. Little more. They had. Good reviews. But it’s not a Honda. But it will be new thanks your your comment

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      If mine needed and inverter, I would do what you do. Change the oil to Synthetic . It will protect your engine in high heat or long running conditions. www.amsoil.com/p/10w-30-synthetic-small-engine-oil-ase/?code=ASEQT-EA&gclid=Cj0KCQiA3smABhCjARIsAKtrg6LbJmsL68tO6hEFB5MxEIrUu6_JYbUGDeBy0YpXDln7fJDvJewN25oaAp6EEALw_wcB

    • @bayardtaylor2990
      @bayardtaylor2990 3 роки тому +1

      @@MartinMetregerTipsandTricks ok thanks. What do you think about the Westinghouse 2200 sport ?

  • @davidfisher3273
    @davidfisher3273 2 роки тому

    Very informative video. Thank you

  • @bramchabochank7489
    @bramchabochank7489 3 роки тому

    How come there's no ignition?

  • @sebastienlapointe605
    @sebastienlapointe605 3 роки тому +1

    Thanks a lot! With your vidéo i save 1000$ !!

  • @randallmitchell2214
    @randallmitchell2214 2 роки тому

    Same exact thing with mine tha
    .thank you, problem solved

  • @williamvaughan1218
    @williamvaughan1218 2 роки тому +1

    Wow there is obviously no throttle servo control and the engine is in overspeed condition. It would be usefull to note voltages at idle to max.

  • @raymugs3036
    @raymugs3036 3 роки тому

    Great video man thanks 👊

  • @AmalgmousProxy
    @AmalgmousProxy 2 роки тому

    Good thing you didn't need an inverter. That box runs between $400 and $500 dollars.
    Question: Where did you get the manual from?

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  2 роки тому

      I searched on google and found it. Unfortunately, it has since been removed. I just searched again and found this halcyontimes.files.wordpress.com/2012/10/eu2000i-repair-manual.pdf

  • @mendonesiac
    @mendonesiac Рік тому +1

    Thanks so much for the great tutorial on how to test for voltage... and your wife is right that you're a nut -- you should never run a generator indoor!!!!

  • @zephyrprime
    @zephyrprime 3 роки тому

    Corrections: Not all AC generators need to operate at a single rpm. Only an ac generator that generates residential power needs to do that because household current is a single frequency (60hz in the USA). An inverter does not generate power by itself. It only turns DC to AC. An inverter generator has a DC generator in it that is connected to an inverter.

  • @vladutnita5627
    @vladutnita5627 Рік тому

    Thank you

  • @jamesbeemer7855
    @jamesbeemer7855 6 місяців тому

    If you had the manual , you would know that , that machine has blue tooth . It will tell you something’s . But if you have to further to diagnose the problem , then this series of vids just might be what you need .
    This generator costs $1166 . Oo from a dealer , and Honda generators are damned neer bullet proof . Don’t throw it away if you don’t have to . The Japanese did us a huge favor as their technology to build things has greatly improved over the past 4 decades . My hats off to them .

  • @csud9540
    @csud9540 3 роки тому

    Thanks man 👍

  • @joeblow8206
    @joeblow8206 5 місяців тому

    Carb spring popped out

  • @JoseLopez-ep9jl
    @JoseLopez-ep9jl 3 роки тому

    Great.. i have the same problem but i think is the inverter ☹

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      Make sure you carefully inspect the wires. Use an ohm meter to check each wire from each connector. My friend works on hundreds of these generators. Never had a bad inverter. But mostly found bad connection or broken wires.

    • @eegg6954
      @eegg6954 3 роки тому

      @@MartinMetregerTipsandTricks The inverters are bullet-proof. I had one that was in salt water for days and it was still fine. Check those wires and connectors!

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  3 роки тому

      @@eegg6954 you're right. Check the wiring.

  • @bramchabochank7489
    @bramchabochank7489 3 роки тому

    Genset Honda eu10i ignition of coil no coil

  • @bramchabochank7489
    @bramchabochank7489 3 роки тому

    Honda coils failed

  • @nishanthademel9114
    @nishanthademel9114 2 роки тому +1

    Hi

  • @johnCamden-w2s
    @johnCamden-w2s Рік тому

    Do you recall a part number for that wire? After an hour of troubleshooting your video took me right to the problem.

  • @johnCamden-w2s
    @johnCamden-w2s Рік тому

    Do you recall a part number for that wire? After an hour of troubleshooting your video took me right to the problem.

    • @MartinMetregerTipsandTricks
      @MartinMetregerTipsandTricks  Рік тому

      I found one at a mower shop that took it off parts inverter. You have to check around or fix the one you have.