Lapping length of steel bars Beam & column calculation in Tamil

Поділитися
Вставка
  • Опубліковано 30 лип 2020
  • As per IS standard what are all the standard neccessary to follow.
    In this video i explained how to calculate the lapping length for column and beam.
    Normally in site we have to take lapping length = 50d, Where d= diameter of the steel bar.
    Lapping location varies based on the BM in the member.
    For column lapping must be in the center of the location.
    Video Links:
    Shuttering IS code : • IS code for shuttering...
    Slop calculation : • Slope Calculation easy...
    IS code concrete : • IS code for Concrete /...
    Calculate Brick work: / watchv=fe15wyr_jgg&t=5s
    Plastering video link : www.youtube.com/watch?v=c2R_v...
    Unit conversion video link - www.youtube.com/watch?v=vMN_d...
    #Lapping length
    #Reinforcement Bar
    #Length of steel bar
    #Lapped bars
    For more details :
    Email : learnertamil97@gmail.com
    Or Any doubt ask me in comment section.

КОМЕНТАРІ • 41

  • @rtfcrtfs9637
    @rtfcrtfs9637 3 роки тому +7

    Well explained brother... Keep Uploading... Thanks 👍

  • @rifaitrends
    @rifaitrends 3 місяці тому

    Super Explanation

  • @vijaycivil9330
    @vijaycivil9330 3 роки тому +2

    Bro super bro engaluku enga ellam doubt varutho athu ellame unga kuda irukura akka kekkuranga very helpful

  • @user-fe9my8wi7q
    @user-fe9my8wi7q Місяць тому +1

    Super 🎉❤

  • @jeenjk2505
    @jeenjk2505 7 місяців тому +1

    Very nice video sir...this video very useful for me

  • @localvibes4468
    @localvibes4468 7 місяців тому +1

    Oh my god really useful.. thank u a lot bro❤

  • @poovarasangp240
    @poovarasangp240 3 роки тому +2

    நன்றி நன்றி அருமையான பதிவு 🙏🙏👍👍

  • @jeenjk2505
    @jeenjk2505 7 місяців тому +1

    Lapping drawing separate ahh varanchi podunga sir...antha column thulaye kirukkathinga onnumea therila

  • @MyRevengers
    @MyRevengers 3 роки тому +1

    Bro i have been following your UA-cam channel for long. You have been doing great job by spreading your knowledge. Kindly do more videos on BBS for structures in detail since you are giving more additional informations on your tutorials. Great job.
    Hope you will upload more videos on BBS.

  • @DavidmaniDavis21
    @DavidmaniDavis21 3 роки тому +2

    Very useful video brother ❤️

  • @Premkumar-ve9xr
    @Premkumar-ve9xr 3 роки тому +1

    Very useful brother

  • @jayakumar3587
    @jayakumar3587 3 роки тому +1

    Good explanation 👍

  • @t.krishnamoorthykrish360
    @t.krishnamoorthykrish360 3 роки тому +1

    Good explain bro

  • @MohanRajAmohanraj
    @MohanRajAmohanraj 2 роки тому +1

    Ties and stirrups pathi sollunga bro

  • @p.premkumar5699
    @p.premkumar5699 Рік тому +1

    Nice explain sir

  • @baranivishal7734
    @baranivishal7734 3 роки тому +1

    Thanks bro

  • @karthickappavoo8857
    @karthickappavoo8857 2 роки тому +6

    Please don't interfere while he is explaining properly

  • @manojkumar-qu8ml
    @manojkumar-qu8ml 3 роки тому +1

    Welding of column lapping for 4*12 mm is good or not for 2 ft distance ( all four bar in same distance) only available above slab for 1st floor only house. Does welding reduce its strength. If ok, how much length does it need to welding

    • @LearnerCivilEngineering8
      @LearnerCivilEngineering8  3 роки тому

      Hi Manoj, As per IS code Welding is not preferable upto 36mm Dia. Instead of Welding do it Coupler for joining. It is Suitable for critical location. Thank you.
      Have a nice day.

    • @manojkumar-qu8ml
      @manojkumar-qu8ml 3 роки тому +1

      @@LearnerCivilEngineering8 thank you sir. But coupler available for more than 32mm only. Is it available for 12mm in market. What will happen if 12mm is welded, will it reduce its strength

    • @LearnerCivilEngineering8
      @LearnerCivilEngineering8  3 роки тому

      @@manojkumar-qu8ml In Market from 16mm Dia coupler available. Welding is not safe for 12mm Dia as per IS code . If you need to know the result do the tensile test & check once.

  • @gunachandar7673
    @gunachandar7673 3 роки тому +1

    Column ku 1.5 feet lap irukalama bro 12mm bar

    • @LearnerCivilEngineering8
      @LearnerCivilEngineering8  3 роки тому

      Hi bro !!
      Lapping length dwg kudutha antha length eduthukonga. Illa na
      Minimum - 45d to 50d
      45x 12 mm = 540mm = 0.54m * 3.28 feet = 1.77feet.
      50 x 12mm = 600mm = 0.60m *3.28feet = 1.96 feet.
      So atleast 1.77feet kandipa kudukanum bro..

  • @madhankumars5582
    @madhankumars5582 2 роки тому +1

    What about beam lapping length sir??