Chiller - Surge

Поділитися
Вставка
  • Опубліковано 18 бер 2017
  • In this video we take a look what what chiller surge is, how it sounds, what causes chiller surge and ways to prevent it. We use 3D models, photos and examples to help you build your understanding.
    LEARN MORE HERE: theengineeringmindset.com/chi...
    Sign up for our FREE engineers newsletter for updates, competitions, news and offers
    🎁 Link: engmind.info/Engineers-Report
    ⚡🛠️ TOOLS YOU NEED 🛠️⚡
    **************************************
    Get this HVACR book ➡️ amzn.to/3XFCaKC
    Professional Multimeter -➡️ amzn.to/3xu2Vaw
    Good multimeter -➡️ amzn.to/3xrbuTd
    Professional clamp meter ➡️ amzn.to/4140FnK
    Good Clamp meter ➡️ amzn.to/3xqt2is
    Outlet tester ➡️- amzn.to/3kavg2l
    Energy monitoring plug ➡️ amzn.to/3SkfPl7
    Battery tester -➡️ amzn.to/3S3fHWI
    Basic electronics kit ➡️ amzn.to/3xuLiqS
    MY FAVOURITE GEAR
    🎥 My camera - amzn.to/3YCZ7Q9
    🎤 My Microphone - amzn.to/3YYXsUC
    ⌨️ My Keyboard - amzn.to/3lBsl33
    🖥️ My monitor - amzn.to/415BGjW
    🎧 My headphones - amzn.to/3lN7R7u
    😎 Get your Engineers T-shirts, Hoodies, Cups & stickers here:
    *******************************
    goo.gl/M1PGrx
    ☕ Buy Paul a coffee to say thanks
    *******************************
    PayPal: www.paypal.me/TheEngineerinMi...
    🙏 Support us on Patreon
    *******************************
    / theengineeringmindset
    🕵️ Check out our website!
    *******************************
    TheEngineeringMindset.com
    👥 Socialise with us
    *******************************
    FACEBOOK: / theengineeringmindset
    TWITTER: / theengmindset
    Instagram: / engineeringmindset
    Google+: www.google.com/+Theengineering...
    UA-cam: / theengineeringmindset
    👀 Links - MUST WATCH!! 👀
    *******************************
    How water cooled chiller works Prt1 - • Chiller Basics - How t...
    How water cooled chiller works Prt2 - • Chiller Basics - How t...
    How Air cooled chiller works - • Absorption Chiller, Ho...
    How Absorption Chiller works - • Air Cooled Chiller - ...
    How Heat Pump works: • How A Heat Pump Works ...
    Primary & Secondary system: • HVAC Primary & seconda...
    Fan Coil Units: • Fan Coil Unit - FCU HVAC
    VAV Systems: • Variable Air Volume - ...
    CAV Systems: • Constant Air Volume - ...
    VRF Units: • Video
    HVAC Basics: • Fundamentals of HVAC -...
    Heat Exchangers: • Plate Heat Exchanger, ...
    Pumps: • Centrifugal Pump How D...
    How a Chiller, Cooling Tower and Air Handling Unit work together - • How a Chiller, Cooling...
    🔧🔨 Tools you need 🔧🔨
    *******************************
    VDE Screwdriver set: amzn.to/2jd4lQc
    Ratchet Screwdriver set: amzn.to/2iDLRsC
    Tape Measure: amzn.to/2zbqq8z
    Drill: amzn.to/2iFj3Qy
    Drill bits: amzn.to/2hK4BG1
    Angle finder: amzn.to/2za6N0s
    Multi set square: amzn.to/2hIpWiY
    Level: amzn.to/2BaHSLJ
    T handle hex allen key: amzn.to/2z9OEjs
    Digital vernier: amzn.to/2hI5K0D
    Hammer: amzn.to/2hJj0lw
    Calculator: amzn.to/2z99yPx
    Multimeter: amzn.to/2Bbq5no
    Head torch: amzn.to/2z84sD7
    Pocket torch: amzn.to/2zWfCyB
    Magnetic wristband: amzn.to/2iEnA5z
    Laser distance finder: amzn.to/2hL4KsM
    Gorilla tape: amzn.to/2zqxiTm
    #HVAC #refrigeration #engineering

КОМЕНТАРІ • 104

  • @EngineeringMindset
    @EngineeringMindset  7 років тому +14

    ⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕
    PayPal: www.paypal.me/TheEngineerinMindset

  • @ronnelson8954
    @ronnelson8954 7 років тому +24

    Really enjoy your chiller/HVAC videos. Can you do one on the oil lubricating/bearing systems of chillers? Also videos on the different motors of screws, scrolls, recips, loading/unloading, etc?

  • @mrgreen9086
    @mrgreen9086 3 роки тому +3

    These videos make so much sense when you know your basic refrigeration cycle, and the seal system. Some great knowledge on this channel.

  • @toyinorodare4072
    @toyinorodare4072 5 років тому +5

    Thank for your clear explanation.
    you actually develop my interest in HVAC training and as at today I can design it.
    thanks a lot

  • @EngineeringMindset
    @EngineeringMindset  5 років тому

    Learn *CHILLER FAULT FINDING* here: ua-cam.com/video/Zu0LVVNNVSw/v-deo.html

  • @TheSkunk1996
    @TheSkunk1996 11 місяців тому

    vARY USEFUL. tHANK YOU FOR POSTING AND DEDICATING YOUR TIME!!!!!

  • @IRSHADKHAN-yy4yj
    @IRSHADKHAN-yy4yj 4 роки тому +1

    Thanks for an easy explanation, I have worked on York OM Titan chiller (5090TR) which had hot gas bypass line.

  • @josephgeorge6189
    @josephgeorge6189 4 роки тому +2

    Excellent explanation! Good job!

  • @karunakaranreddy7274
    @karunakaranreddy7274 6 років тому +2

    Nice and thanks Awaiting for VGD and PRV Control in chiller

  • @alak3073
    @alak3073 5 років тому +3

    thank you very much for your efforts

  • @sadiqueahmad9508
    @sadiqueahmad9508 4 роки тому +11

    What is chiller surge?
    It's basically an unwanted situation which occurs due to difference in pressure between outlet and inlet of compressor. It may occur if the temperature of the condenser raises to a level at which the pressure becomes more at the outlet of compressor (going into the condenser) .

    • @shivaHVAC
      @shivaHVAC 3 роки тому +1

      How to avoid this issue?

  • @MaTHEUuuS051
    @MaTHEUuuS051 3 роки тому

    It is very useful! Thanks a lot

  • @fadiyasin
    @fadiyasin 6 років тому +3

    very good job
    thaaanks

  • @Pito422
    @Pito422 6 років тому +1

    again, great videos dude.

  • @rickyhurtado2895
    @rickyhurtado2895 12 днів тому

    Thanks,for good information

  • @shaikhmudassirazmi6934
    @shaikhmudassirazmi6934 6 років тому +2

    Thanks for this video
    Please upload design of hvac
    HAP software related video
    Please sir its a humble request

  • @CircinusMusic
    @CircinusMusic 2 роки тому

    Thank you for the knowledge u share

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 8 місяців тому

    Thank you for sharing.

  • @lamichaelkreitz6821
    @lamichaelkreitz6821 4 роки тому +7

    As a Daikin Factory service tech (who was working on these today) I must say I love to see you using our machines as a template for your graphics. I love your videos and this one (although review) is no exception. Cheers!

    • @unclemonster48
      @unclemonster48 4 роки тому +1

      LaMichael Kreitz us old mcquay boyz cheers

    • @reyruiz7763
      @reyruiz7763 3 роки тому

      Trane no daikin

    • @OTHG6v
      @OTHG6v 2 роки тому +1

      Left Mcquay in 2005, Trane till 2016 and now I do service for them.

    • @lamichaelkreitz6821
      @lamichaelkreitz6821 2 роки тому +1

      @@OTHG6v I’m happier here at Daikin than I’ve ever been in this trade! Great company to work for! I absolutely love engineering mindset videos as well.

    • @kaptaintrips
      @kaptaintrips Рік тому +2

      @@lamichaelkreitz6821 You Daikin guys sure love your pannels and stripped out screws...
      Still decent engineering compared to others (cough, Carrier).
      When it comes to chillers, give me a complicated centrifugal any day. Then perhaps a screw...

  • @emanuels.6541
    @emanuels.6541 Рік тому

    Good stuff. Thanks much

  • @ibrahimosman3393
    @ibrahimosman3393 7 років тому +3

    Good efforts waiting for ammonia systems

  • @patricktsang1041
    @patricktsang1041 3 роки тому

    Fantastic video!

  • @Jgriffin0808081
    @Jgriffin0808081 3 роки тому

    Awesome vid keep em coming

  • @everestinspections9088
    @everestinspections9088 Рік тому

    great video thank

  • @gabrielmanut
    @gabrielmanut 2 роки тому

    Saudações aqui do Brasil.
    Antes de mais nada, quero agradecer e parabenizar pelo conteúdo. Não sei como não tinha visto esse canal antes.
    Não tinha percebido o "SURGE" dessa maneira.
    Se não for incomodar muito, poderia responder algumas perguntas?
    1- Existe surge por baixa pressão? Onde o "Lift" do compressor fique abaixo do seu limite? Já tivemos casos aqui, que só resolveu corrigindo a vazão no evaporador.
    2- A rotação do compressor realmente gira no sentindo inverso? Ou só desacelera?
    3- Como posso criar conteúdos tão maneiros com esses modelos 3D? Ficou excelente.
    Mais uma vez agradeço

  • @franzpaez3882
    @franzpaez3882 6 років тому +2

    Can you please also discuss about Oil Migration in Water-Cooled Centrifugal Chiller. Thank you in advance.

  • @WillieMakeit
    @WillieMakeit Рік тому

    Thank you very much

  • @MrBerniebling
    @MrBerniebling 6 років тому +1

    nice content, thank you

  • @BasketballAve
    @BasketballAve 10 місяців тому

    Excellent video

  • @hectortorres542
    @hectortorres542 7 місяців тому

    Thank you

  • @muhammadawais6336
    @muhammadawais6336 5 років тому +1

    please make on video on lastast sorew compressor and that parts.

  • @muhammadawais6336
    @muhammadawais6336 7 років тому +1

    please make vedio abuot cool water chiller expension valve

  • @morabitaziz9787
    @morabitaziz9787 5 років тому

    thank you for this védio
    i am from moroco

  • @khaleejkha4026
    @khaleejkha4026 7 років тому +1

    thanks sir

  • @muhammadawaisashraf2629
    @muhammadawaisashraf2629 2 роки тому

    Very good video

  • @hafizshams5077
    @hafizshams5077 6 років тому +1

    Can you do a more detail video about bypassing the effect of surge.thanks

  • @ToothyGus
    @ToothyGus 5 років тому +1

    Same principle as a centrifugal compressor surge but that one is really scary to stand next to :)

  • @thabisopaul528
    @thabisopaul528 7 років тому +1

    I want more Industrial practical on refrigeration and air conditioning since I got diploma in mechanical Engineering.

  • @ISLAHIQALB
    @ISLAHIQALB 5 років тому +1

    Awesome quite fabulous it’s great quite

  • @munimechanical3942
    @munimechanical3942 3 роки тому

    Hi sir iam maintained at 1000tr Daikin chiller your video is very usefull

  • @PunKMeTaLicE
    @PunKMeTaLicE 6 років тому

    Hi! I am curious that if the condenser water return is too low such as 21-23C , any issues or problems will be appeared? THANKS! Your videos are really helpful!

    • @EngineeringMindset
      @EngineeringMindset  6 років тому +3

      Depends on the chiller. Some, older ones, need very stable operation but newer ones are made with variable conditions but still have some minimum and maximum temperatures and pressures. If the chiller approaches these limits it will trip and cut the power to protect itself. Check the chiller specifications

  • @karunakaranreddy7274
    @karunakaranreddy7274 6 років тому +1

    Could you please explain briefly the VGD in terms of function and control

  • @reyruiz7763
    @reyruiz7763 3 роки тому +1

    Thanks, not everyone take the time to share knowledge these days.

  • @kyawmyintthan2869
    @kyawmyintthan2869 4 роки тому

    Would an oversized non return valve in the discharge pipe help alleviate this problem.

  • @kavernianengineering2959
    @kavernianengineering2959 4 місяці тому

    Hellow, its allowed integrate a variable speed control on existing chiller with constant speed ?

  • @mastadonwesley1042
    @mastadonwesley1042 2 роки тому +1

    Our Tranc chillers always surged when the auto fill malfunctioned and the return was starved for water causing the condenser to overheat.

  • @Luzt.
    @Luzt. 6 років тому +4

    At t=292 you said about too great pressure and back flow. This is a description but not an explanation. What exactly happen with gas in the rotor just before/at/after the moment when this critical pressure is achieved? In particular why after achieving this equilibrium it does not become stable/static without flow.

    • @EngineeringMindset
      @EngineeringMindset  6 років тому +3

      before it becomes compressed and heated. At, it finds a route with lower pressure/resistance which means backwards. After, it flow towards the least resistance which is forwards. It can't reach stability because there are different pressures on either side of it and heat is being added or removed.

  • @ahmadjaber2818
    @ahmadjaber2818 6 років тому +1

    Hi, first of all it's a great video, But i have a question,does the pressure relief vents prevent some how the chiller's surge? Thanks in advance.

    • @unclemonster48
      @unclemonster48 4 роки тому

      ahmad jaber they are emergency blow offs in case of a pressure switch failure or issue with the machine keeps running past the fail safe pressures. It vents the refrigerant to avoid vessel rupture

    • @unclemonster48
      @unclemonster48 4 роки тому

      Surge is just when the machine loses its lift due to being out of its design specs of running. For example someone raises the set point on the cooling tower and lowers the set point below design set point. Your out of balance and the liquid level in the evap will fall there fore affecting the impellers ability to lift the vapor from the lower liquid level in the evap. This is just one scenario, several factors can make a centrifugal chiller stall and surge.

    • @EngineeringMindset
      @EngineeringMindset  Рік тому

      Seen our new pressure switch video? Link: ua-cam.com/video/YG81w0HFXNc/v-deo.html

  • @vhienandrade5353
    @vhienandrade5353 3 роки тому

    What caused the chiller trip? By the way thanks to your vedeo

  • @Your_searching_ends_here
    @Your_searching_ends_here 6 років тому +1

    Frm discharge to oil seperator nd then condenser

  • @americafirst6016
    @americafirst6016 3 роки тому

    Couldn't surge be cause by adaptive purge not working correctly or not purging enough?

  • @yijiangwang5783
    @yijiangwang5783 4 роки тому

    Could you reply what's the different between this surge system and and condenser tube clean, are they the same system ?

    • @krish6790
      @krish6790 3 роки тому

      Chiller surge can be of any system where the condenser pressure is greater then the compressor discharge.. now these chillers condensers can either be water cooled or air cooled, if they are water cooled you can definitely clean their tubes by carrying out proper shut down operation etc and/or wash condensers if air cooled..

  • @capitolrefrigerationheatin7501
    @capitolrefrigerationheatin7501 6 років тому

    why isnt there a check valve in the discharge of compressor like hermetic compressors have?

  • @Rajajaber1977
    @Rajajaber1977 3 роки тому

    Exclent

  • @superinggotv5622
    @superinggotv5622 2 роки тому

    Surge troubleshooting in contactor amperage

  • @mmfeiw8664
    @mmfeiw8664 3 роки тому

    why does it also surge while the load decrease but pressure differential maintained?

  • @menskills6368
    @menskills6368 4 роки тому

    Why does the chiller surge if the entering water sensor on the evap is bad ? (Changed it because the readings was too high and it worked fine after )

  • @karrarkarrar2529
    @karrarkarrar2529 5 років тому +1

    why increase pressure in the condenser

  • @saqibomer2458
    @saqibomer2458 3 роки тому

    Add chiller display details video

  • @abhimat
    @abhimat 5 років тому

    What is the hot gas bypass line? And what is this word you use often - velute or flute?

    • @EngineeringMindset
      @EngineeringMindset  5 років тому

      Gas bypass: ua-cam.com/video/K0xAKzdROEg/v-deo.html
      Volute: theengineeringmindset.com/centrifugal-pump-basics/

  • @user-wq9mm1vg6p
    @user-wq9mm1vg6p 10 місяців тому

    What are the differences on how chiller surge occur for an air-chilled system?

  • @rajanrai2285
    @rajanrai2285 2 роки тому

    Surging setting ?

  • @aboodi297
    @aboodi297 6 років тому

    Can you explain who Low section Temperature happen and what is the reason with solution

    • @EngineeringMindset
      @EngineeringMindset  6 років тому

      Could be a lot of things, low refrigerant level, faulty or incorrect sized expansion valve, wrong refrigerant used. Best to take some screenshots of the VDU, check the fault code and look in the service manual to diagnose the problem.

    • @EngineeringMindset
      @EngineeringMindset  6 років тому

      We just covered chiller faults in our recent video! ua-cam.com/video/Zu0LVVNNVSw/v-deo.html

  • @mzs9262
    @mzs9262 7 років тому

    please answer this , if there is good heat transfer in the condenser as you describing in the video ...
    then There is only removal of the latent heat ,...
    The temperature and pressure remains same.
    Then how we can eliminate the Surging phenomenon please tell...?
    Because for surging we have to decrease the pressure from the condenser ?
    Please correct me if i am wrong !!!

    • @EngineeringMindset
      @EngineeringMindset  7 років тому +2

      Many things affect this, the supply and return temperature of the water, the flow rate of the water or refrigerant etc etc. If your chiller is surging then you should contact your service provider or manufacturer for assistance asap.

    • @altamashshh1984
      @altamashshh1984 6 років тому +1

      Muhammad Zaroon Surging in itself happens when there is improper heat exchange caused by the combine effects of fouling,flowrate variation Etc etc inside the condenser...which directly leads to lower heat transfer and hence higher temperature and pressure build up.So your statement that the temperature remains constant is incorrect

  • @TheChillerGuys
    @TheChillerGuys 3 місяці тому

    Sounds like a high quality shop vac when they surge

  • @jeejiean
    @jeejiean 4 роки тому

    Thanks for the explanation!
    One of my chiller here was really troubled by those surging problems. The hot gas bypass, guide vane & VFD compressor seems like cant really coordinate well and suffered from surge tripping while the heat load was dropped suddenly (change of shift in a factory).
    The chiller part load table claimed that it was able to provide up to 15% part load, but the chiller just refused to run in so low speed (Chiller tripped in around 60% part load)
    While we are pretty sure most of the parameters (condenser delta T, flowrate, etc) was good during chiller surging, we are deeply troubled by this centrifugal chiller
    Any idea or thought of this? Thanks in advance for any comment!

    • @unclemonster48
      @unclemonster48 4 роки тому

      jeejiean what brand of machine? Is it variable speed? Most machines struggle at part load anyways.

    • @EngineeringMindset
      @EngineeringMindset  4 роки тому

      VFD Video is now live! here: ua-cam.com/video/yEPe7RDtkgo/v-deo.html

  • @mrabby8537
    @mrabby8537 2 роки тому

    Why compressor oil comes in the evaporator, even if an oil separator is installed. Evaporator tube leakage oil, water, and refrigerant mix in my case. I will be very grateful if you make this video by giving the real reason.

  • @twincam825
    @twincam825 2 роки тому

    Or tower filler coming apart blocking drip orifices top of tower ,

  • @romeopascual6122
    @romeopascual6122 3 роки тому

    The chilled water cycle is not completed you need to add. The expansion tank for the make up refill the lost chilled water supply. Thanks.

  • @SombraLocs
    @SombraLocs 5 років тому

    What are the causes of a low end surge?

  • @rhed321
    @rhed321 Рік тому

    Vanes are already controlling the flow of refrigerant then why a VFD or variable diffuser is required?

    • @EngineeringMindset
      @EngineeringMindset  Рік тому

      Vfd changes the rotational speed of the motor otherwise its a constant speed

  • @gregdaborn4620
    @gregdaborn4620 6 років тому +2

    The pumps should be pushing the water through the chiller, not drawing it through.

  • @OTHG6v
    @OTHG6v 2 роки тому

    Velocity across the impeller increases until it can’t.

  • @brlinrainf
    @brlinrainf 3 місяці тому

    Expansion vavle

  • @caleblo8498
    @caleblo8498 Рік тому

    click~

  • @romeopascual6122
    @romeopascual6122 3 роки тому

    T

  • @mdmansafali8182
    @mdmansafali8182 2 роки тому

    In hindi

  • @FixItStupid
    @FixItStupid 8 місяців тому

    TY