Under Voltage Release (UVR) coil installation in 800A MCCB of control panel part-1.

Поділитися
Вставка
  • Опубліковано 15 жов 2024
  • #business #entrepreneur #success #onlineshop #smallbusiness #marketing #branding #marketingdigital #love #innovation #training #instagood #art #nature #photooftheday #follow #electric #electronic #india
    ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
    Brief information on the use of UVR.
    _____________________________________
    An under voltage release mechanism is fitted to all generator breakers and some main feeder circuit-breakers. Its main function is to trip the breaker when a severe voltage dip (around 50%) occurs. This is achieved by lifting the mechanical latch (which keeps the contacts closed) to allow the trip spring to function which opens the breaker contacts. The U/V release on a generator circuit-breaker also prevents it being closed when the generator voltage is very low or absent. Undervoltage relay, which may be magnetic or electronic, also provides back-up protection to short-circuit protection. As an example, suppose during generator paralleling procedures, an attempt was made to close the wrong circuit-breaker e.g. the breaker of a stopped and dead generator. If this circuit-breaker was closed, the dead generator would be the equivalent of short-circuit fault on the bus-bars and cause a blackout. The undervoltage relay prevents the closure of the circuit-breaker of the dead generator. Undervoltage protection is also required for motor starters. The starter contactor normally provides this protection as it drops out when the supply voltage is lost or is drastically reduced. The starter circuit will not normally allow the motor to re-start when the voltage supply is restored except when special automatic restarting facilities are provided. Undervoltage protection can be electro-magnetic or electronic. Checking and calibration of generator undervoltage relays can only be done accurately by calibrated voltage injection. A known variable voltage is directly applied to the undervoltage relay to check: The voltage at which the relay pulls-in The voltage at which the relay drops-out Generator U/V relays are usually slugged to allow a time-delay which prevents spurious tripping during transient voltage dips (typically 15%) caused by large motor starting currents.
    #business #entrepreneur #success #onlineshop #smallbusiness #marketing #branding #marketingdigital #love #innovation #training #instagood #art #nature #photooftheday #follow #electric #electronic #india

КОМЕНТАРІ • 2

  • @pramodkumar-le3rw
    @pramodkumar-le3rw Рік тому +1

    आप के वीडियो में आवाज नहीं है

    • @IndoeconEngineers
      @IndoeconEngineers  Рік тому

      Yes, there is no sound in this video. The information given in it is in written form. Will make it with voice in the upcoming video. Thank you for your suggestion!