Tektronix Double Pulse Testing - Energy Loss Measurements Demonstration
Вставка
- Опубліковано 30 сер 2022
- This video explains how to use Tektronix oscilloscopes with Double Pulse Testing software to make accurate, repeatable energy loss (EON and EOFF) measurements.
Watch and see how switching performance of power semiconductors is often characterized using double pulse tests. This testing is now being widely applied to GaN and SiC MOSFETs.
5 Series B MSO: www.tek.com/en/products/oscil...
6 Series B MSO: www.tek.com/en/products/oscil...
4 Series MSO: www.tek.com/en/products/oscil...
AFG31000 (Arbitrary Function Generator): www.tek.com/en/products/signa...
Visit our website www.tek.com/ for all the Tektronix related content and solutions.
#Tektronix #Oscilloscope - Наука та технологія
But I have no oscilloscope so how to make this measurement without equipment ?
Smoke.... If the parts smoke, they failed the test. Start over and turn down the voltage.
@2:55...Ch6 grounds the MOSFET, the current thru current resistor will be wrong.
Ground should be together with current shunt ground