  • Pulling Out Submersible Well Pump No Water.Our water suddenly stopped flowing into our house. David thinks the submersible pump has stopped. It is 15 years old. He first made a tool to hold the hose so he could take a break pulling out the very long hose. It worked great plus he had some help from our son Colin too.
    music KineMaster App
    #troubleshootingsubmersiblewellpump #wellpump #nowaterinhouse
  • Навчання та стиль

КОМЕНТАРІ • 40

  • @Sylvan_dB
    @Sylvan_dB Рік тому +12

    Wow, at 9:30 seeing that pump come out detached from the pipe... You are so lucky it came up!

  • @texasstadium
    @texasstadium 3 місяці тому +1

    Once upon a time in 1999, during a one-day deluge that was the all-time record rain in Juneau Alaska, I pulled a submersible pump by hand from 250 feet. I did it alone at 52 years old. I can tell you that was quite a chore.
    Walking the pipe the length of a football field and anchoring it in place to allow the next grab/tug at the well head was the biggest challenge. Over the years, my orthopedic surgeon has benefited greatly from these performances.

  • @dave_in_florida
    @dave_in_florida 11 місяців тому +4

    great to see common man do the job. I literally gasped when I saw the pump come up broke off the pipe and dangling by the wires!!

  • @ronie1337
    @ronie1337 6 місяців тому +4

    Nice job! Betcha the torque twisting from when the pump started may had something to do with the pvc snapping off.. next time go with a stainless steel short nipple to stainless steel check valve to stainless steel mpt / barb male adpt. fitting. Also add a pull rope on the submersible pump.

  • @smtxtv
    @smtxtv Місяць тому

    Great info. Thx !

  • @jimcochrane7826
    @jimcochrane7826 7 місяців тому +4

    Inside the well please use stainless or at least brass fittings on the pump to the black roll. Tape the wires well to the tubing and use a safety rope, just in case things come apart in the well as in your case. I would never use pvc fittings inside a well. They are simply not strong enough to take all the pump starts.

  • @bababooey7576
    @bababooey7576 Рік тому +6

    Stainless steel fittings. 2 clamps --all stainless. Double sided tape

  • @cupwalker24.7
    @cupwalker24.7 Рік тому +2

    When Lee says wiggle it just wiggle it ;) ..... Thats what we do Behind the Rig while drilling or pulling back pumps while saying lots of sware words 🙏🙏. Hold your tounge correctly and then it comes free and its the best feeling in the world ...unless the well collapses then it's no fun 😂

  • @OOparker
    @OOparker Рік тому +1

    Great job. Going to pull mine needed a refresher haven't done it since 2002 before I I had internet. LoL thanks 👍

  • @tracykey9227
    @tracykey9227 Рік тому +3

    Great "real world" DIY video; thanks for your time sharing it. Imagine your buddy told you the white particles were likely PVC from your scraping up the side of the pump, since it was pulling up at an angle, hanging by the wires; lucky the wires held lol. If the pump was still working, I'd of kept it, being quality is not at all what it was even 15 years ago. Im bout to pull mine to add a check valve at the pump, snice it appears mine is bad or I have a hole in my drop pipe. I bought my house in 05 with the same pump, and it's still working, so gonna drop it back down the well.

  • @thepenultimateninja5797
    @thepenultimateninja5797 Рік тому +1

    I was on the edge of my seat watching this lol.

  • @Nctbgs
    @Nctbgs 11 місяців тому +1

    Wow. That looks like it was close to loosing the pump in the well. I didn’t see a safety rope hooked to the pump either . Sure glad those wires held . Great video.

  • @williamgarrity9482
    @williamgarrity9482 Рік тому +1

    My well is 375 feet deep ,I had a company pull n replace pump some ten years ago. I will do it myself aft seeing your holding wood brace clamp thingy, thanks for sharing. God bless yall real good. From southern MD.

    • @PRC533
      @PRC533 11 місяців тому +2

      at 375 feet, you won't probably be able to pull it up by hand, that's a lot of weight. You can use a 4 wheeler, riding mower or something to help you pull it out if needed, just make sure you have something or someone keeping it from rubbing as it comes out. Also, if it's on stick PVC or galvanized pipe you will need a crane.

  • @deniseandmarkfirestine7443
    @deniseandmarkfirestine7443 Рік тому +8

    Should use stainless fittings to connect to black poly pipe

  • @YoMamma-dy8gu
    @YoMamma-dy8gu 5 місяців тому

    I'm delighted to see your wood block/clamp device... I had almost the same exact idea! The hinge is genius. I'm going to do the same exact thing!

  • @roccoelleto9900
    @roccoelleto9900 Рік тому +1

    Fantastic DIY video. Will be helping my father-in-law replace his very shortly.

  • @WeThePeople9069
    @WeThePeople9069 Рік тому +1

    Brilliant!! Thank you sir!

  • @TheArmedExile
    @TheArmedExile 9 місяців тому

    Great job

  • @miklby
    @miklby Рік тому +4

    The reason it broke is because of the male PVC adapter, it is probably the weakest PVC fitting that there is. I had one fail too. It didn't completely brake but it had a crack and we couldn't get any pressure. What I use is a Close Pipe Nipple and a Female PVC adapter, this fitting is super strong compared to the Male PVC adapter. The Close Pipe Nipple goes into the pump and the Female PVC adapter goes in place where his broken Male PVC adapter was...

  • @PapaSpades
    @PapaSpades 13 днів тому

    That hinge!

  • @christianfigueroa1517
    @christianfigueroa1517 28 днів тому

    Next time u wanna check the pump… just test the pump leads by checking for continuity and takin the pump off the motor and that try to spin the shaft…. Theres also a bearing height checker u can order

  • @boxerdiesel
    @boxerdiesel Місяць тому

    Gran bel lavoro!
    Complimenti.
    A breve dovrò intervenire sulla mia pompa, il pressostato perde pressione e per fare partire la pompa devo aprire l'interruttore manualmente. Temo sia la valvola di ritegno andata. La pompa è assicurata ad una corda. Dovrò installare tra pompa e valvola di ritegno un cilindro di ghisa contro la corrente galvanica. Dalle analisi pare che la falda granitica sia corrosiva per i metalli

  • @PRC533
    @PRC533 11 місяців тому +1

    I don't remember if you mentioned the wiring, but if that wiring didn't get replaced it's likely to give you trouble in the near future after being stretched and yanked on like that.

  • @terrybraun4175
    @terrybraun4175 4 місяці тому

    Nice video. Although I've never known of a well where the casing does not go all the way to the bottom. Probably not the case here either. I'm guessing since it was pulling from the wires and the wires are on the side of the pump it was not pulling straight up on the pump and that's why it was getting stuck. Another thing is when you treated the well and had the chlorine in the house, I've always been told chlorine will damage the diaphragm in the pressure tank.

  • @johnbutler5208
    @johnbutler5208 3 місяці тому +1

    Never ever use pvc at the top of a pump

  • @andrew-cm3zn
    @andrew-cm3zn Місяць тому

    Never use pvc fittings in well or bores as they break

  • @ronsmith9218
    @ronsmith9218 Рік тому

    Our 2 hp pump and motor weigh another almost 20+ kg or 50 lbs. So you just cannot manually pull that kind of weight without a winch/comealong system. Good luck.

  • @joevip76
    @joevip76 11 місяців тому

    Quick question please, how long did your new well pump hold up, I've had minenew 3/4 HP installed in in 2021, 2023 got fried by lightning storm. Please just wanted to know if you didn't get a bad pump like i ended up with. 🙏 Thanks

  • @ronjclm8590
    @ronjclm8590 7 днів тому

    PVC is NEVER anoption for attaching a pump to either end of a submersible pump. Also. I see people installing pumps without a 1/4 inch poly rope attached as an extra safety system in case the pump becomes detached from the pipe.

  • @buddyroe
    @buddyroe 5 місяців тому

    Didn't need the homemade stop, you should have put the pool shock in before you put the pump back in, now you have acid on your wires and black pipe

  • @HxC_Fragman
    @HxC_Fragman Рік тому

    No pitless adapter?

    • @PRC533
      @PRC533 11 місяців тому

      those aren't used everywhere.

  • @ronsmith9218
    @ronsmith9218 Рік тому

    If you have a pichancha (check valve) then the pipe is full of water. If you have 1.5 inch pipe and water weight 1.9 kg per meter. Well is 60 meters so do the math first to know what you are lifting. the other vid pulling pvc pipe up through a sleeve on the tree is what will be needed. And a second carrick bend friction knot will be needed to hold the pipe while you reset the main friction knot. We have a 4 pod 12ft high and a chain winch that pulled the original 2 inch steel pipe using a clamp designed to hold the pipe down low at the ground at the coupling lip while resetting the winch hook, lifting a few meters at a time.

    • @mikoro88
      @mikoro88 Рік тому

      That little pipe can't possibly contain almost 2 liters of water pr. Meter? 😮
      If the *inner* diameter is 1.5 inches (3,81cm), the volume would be 1.14 liters/kg's per meter of tube. At 60 Meters, the filled tube (even at 1.5 inch inner D) would only weigh 68,4 Kg. (~150 lbs) 😅

  • @kingtut5923
    @kingtut5923 Рік тому

    I guess you never watched any other well video , make yourself the wheel

  • @talusranch990
    @talusranch990 11 місяців тому

    Use stainless only

  • @kidbowjb
    @kidbowjb Місяць тому

    They broke the pump off pvc while pulling it up

  • @davidbulich1254
    @davidbulich1254 7 місяців тому +1

    Never use plastic fittings