Mastering the Technique of Mounting a Ledger Board

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 18

  • @michaelwright6742
    @michaelwright6742 11 місяців тому +5

    You're a trooper! I live in Centralia, Washington and am intimately familiar with the rain. I really like that you are local to me and use the same materials available to me. I've learned a lot from you and enjoy watching.

    • @carstenbuilds
      @carstenbuilds 11 місяців тому

      Same here I’m over in puyallup!!

  • @lonnieclemens8028
    @lonnieclemens8028 4 місяці тому +1

    I admire you for working in the rain. I admire you even more for being knowledgable about the code.

  • @loco4dogg
    @loco4dogg 11 місяців тому +1

    Great videos, I've learned a lot.
    Here's one for you, I've got a cantilever deck which I'm enlarging. Codes require me to remove this deck and start fresh, this means I have to cut the existing cantilever deck and interior joist back to install a rim joist then a ledger board. Have you done this before, how would you recommend cutting back the joists to install the rim joist?

  • @jimmydeejr8792
    @jimmydeejr8792 11 місяців тому +1

    When attaching the ledger board to solid concrete wall with spacers would you recommend anchors or bolts with Epoxy?

  • @T.E.P..
    @T.E.P.. 11 місяців тому

    Merry Christmas to you and all you love .... super glad to have found your glorious channel ... Hello from Minneapolis MN

  • @troyqueen9503
    @troyqueen9503 11 місяців тому

    GRK makes a ledger board spacer for your air gap .👍🌴🇨🇦

  • @tonyaiello6463
    @tonyaiello6463 11 місяців тому

    How about putting a air gap barrier between ledger board and house such as Hydro Gap?

  • @tomacquilano1304
    @tomacquilano1304 22 дні тому

    Shouldn't the ledger board be pressure treated lumber?

  • @bobwhelk2117
    @bobwhelk2117 11 місяців тому

    Ever worried about hitting utilities that may be butted up to belly board ( what if basement is finished?)

  • @stewarthalstead6802
    @stewarthalstead6802 11 місяців тому

    7:13pm Cali Time. How many work days/year are you completely rain suited up?!

    • @toothpaste22
      @toothpaste22 11 місяців тому

      No more than a week combined, where the union work at im tired watching people work on youtube

  • @ianhaskell5736
    @ianhaskell5736 11 місяців тому

    Dude! Don’t you think it’d be easier to slide your L flashing up behind the building paper behind the T1-11 before you install your ledger board?

    • @ianhaskell5736
      @ianhaskell5736 11 місяців тому

      Seeing your update video, I guess you did manage to get some flashing in there….i guess if your flashing upper leg is short enough you can manage it

  • @josephcook8264
    @josephcook8264 11 місяців тому +1

    I quit attaching decks to the house over 30 years ago! Just put in posts and beams instead of! I have rebuilt others “builders” deck far too many times to repeat their mistakes!!

  • @jeffguenther223
    @jeffguenther223 9 місяців тому

    Why did you install the ledger 1-1/2" below t-111? Is that just a random spacing?

    • @509vista
      @509vista 7 місяців тому

      To leave room for the decking material to tuck under the siding........

  • @egACRE
    @egACRE 8 місяців тому

    can a ledger board be two boards thick? problem is i have 1" 1/2 styrofoam on my exterior walls. need to get out past that for deck boards.