Surprising that the master toggle switch on that unit does not even have a weatherizing rubber boot, despite being exposed to the elements. That and the plastic fan makes one think that these things are not made to last!
Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?
Hi am watching all your videos it's really good and see how we r working it's good but I ve a doubt because am not sonfamiliar with starcool reefers can u explain how to intiate manual operation in starcool
Starcool reefers can be operated in Manual and auto. You can navigate it in the service menu and can shift whichever operation you want. In manual you can also switch on and off your compressor, condenser motor, evap motor and open and close your expansion valve, hcg and economizer.
leckyjake Yung nasa monitor po kase sir Alarm 52 ang nakabungad tapos kapag iaarow down ko yung button nakalagay alarm 1-alarm16 Yung alarm 52 po alarm list full yung definition nya sir. Problema namin kapag may bagong alarm hindi maka appear sa board kase full. Salamat sir
@@leckyjake that’s a shame as I was thinking that if you can get air miles rewards points you surely could get sea miles reward points. Maybe you should ask your bosses about it🤔
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much halp pls
Sa starcool unit pwede mo manually Activate ang solenoid coil. Pag di nag activate ang coil sira ang coil mo or baka walang output ang controller mo. Pag nag activate naman at walang click na marinig then sira ang valve mo.
Thank you lecky for sharing your knowledge,leckyjake pwdy po bang humingi sana ng favor if ok lang,sir meron po kayong software ng lahat ng troubleshooting ng refeer container,like career,star cool,daikin etc.slmt po sir lecky jake,God bless po
Interesting, for sure, but I'd kill the "music". I have to keep turning down the volume, then turning it up so I can hear your narration. Less is more!
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much halp pls
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much halp pls
Very skillful lecky rare to find good and knowledgeable this days. Stay Safe,
from 🇸🇬 .
Sir,These are important lessons of refers,coolers, and etc..This is great help to me.
Thanks sir SA maganda TUTORIAL ninyo keep more power 💪 God 🙏
Proud Pinoy 🇵🇭🇵🇭
Keep up the great work and excellent videos. You have found a niche on UA-cam and you are doing great work.
Stay safe and enjoy the high seas.
Thank you Jake really appreciate the videos. Saying hi from Ottawa Canada.
Thank u idol sa mga vedio mo na nakita ko ayus dagdag kaalam to para sa akin
U are very skilled elecky hard to find these days
I appreciate you for this video.
I am learning a lot from you
Thank you very much for watching
Very helpful for New electricians
god bless always sir... Same container we are handling MCI REEFERS
Hope u can add more videos about reefer troubleshooting bro.. its very usefull for a MNR & reeferman like me. Haha.. thanks to share👍🏽
Nice info and video about reefer.. keep up the good job leckyjacke👊
Thanks Brother Very Helpfull keep going
Thank you this info very goods. Kind Regards
Very nice bro.I request if you can minimise the back ground msic ..that could be more better.thank .
Godbless... Ayos blogger kna Pala dami muna Pera heheh.. Sna naalala mo pa ako sa MOL LONDRINA na barko heheh
Thank you for those types
superb
Please make a video about thermo king shipping container troubleshooting,any trouble and familiarisation on the controller.thanks
Thank you sir
Surprising that the master toggle switch on that unit does not even have a weatherizing rubber boot, despite being exposed to the elements. That and the plastic fan makes one think that these things are not made to last!
how many years have you been doing this kind of work?
Is it the Owners Crews duty to maintain temperature logs from the Reefer Containers and do they repair the same??? Or the Charteres Crew repairs them?
Whoever is onboard
hi any job have electrical help my age 39 experences 15 year 5 half
Hi my friend Leckyjake, I'm speaking from Brazil, I'm trying to find out about the Alj281 from the Daikin container.. Other than the SMV valve, the SMV coil, and the solenoid coils, what else can cause this alarm?
Hi am watching all your videos it's really good and see how we r working it's good but I ve a doubt because am not sonfamiliar with starcool reefers can u explain how to intiate manual operation in starcool
Yes I want to know
Starcool reefers can be operated in Manual and auto. You can navigate it in the service menu and can shift whichever operation you want. In manual you can also switch on and off your compressor, condenser motor, evap motor and open and close your expansion valve, hcg and economizer.
@@leckyjake thank u keep doing
you can only do so within 5 minutes of continous manual operation
Hey buddy what ship you on? Next time you're in Port I'll come up and say hi. I'm a Reefer Tech in Savannah.
sure, I'll be joining Maersk Sofia soon
@@leckyjake awesome man I can't wait.
How's salarly for reefer technician
👍👍👍
Nice
Muito bom
Sir tanong kulang carrer trancold chiller hindi nag outomatic kc off and on ang unloader nya kya diretso andan ang comp nya anu kaya problema nya sir
thank sir
Sir do you have a manual
Hello Sir! Ang galing mo po.
Sir mag paturo lang sana ako kung paano mag reset ng alarm sa carrier thinline reefer? Sana po ma notice nyo salamat po
Depende sa alarma. Anong alarm ba meron mo?
leckyjake Yung nasa monitor po kase sir Alarm 52 ang nakabungad tapos kapag iaarow down ko yung button nakalagay alarm 1-alarm16
Yung alarm 52 po alarm list full yung definition nya sir. Problema namin kapag may bagong alarm hindi maka appear sa board kase full.
Salamat sir
Have you ever calculated your mileage travelled on the high seas? Great video as usual
I should have thought about this 10 years ago hahaha thank you
@@leckyjake that’s a shame as I was thinking that if you can get air miles rewards points you surely could get sea miles reward points. Maybe you should ask your bosses about it🤔
@@simvrod what's sea miles
Thank lecky
How do u know these all things to repair I think somebody will trained u
It happens when the expansion valve does not lock correctly because of the coil, the passage of refrigerant is too much 😊👍
Please make a video how to recharge freon
Thanks lecky jake
24v ba ang coil ng mga contactor nyan sir?
Hi jack,,,i like your job,,i want be like u,,,ETO,,,but how?
Sorry sir, what is the cause of the freezer container carrier display not turning on, please explain 🙏
Good day, do you have education courses online?
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much halp pls
Lecky jake. Curious lang ako. Pano malalaman kung defective yung mga valve na yun just by running it manual? Medyo naguguluhan ako.
Sa starcool unit pwede mo manually Activate ang solenoid coil. Pag di nag activate ang coil sira ang coil mo or baka walang output ang controller mo. Pag nag activate naman at walang click na marinig then sira ang valve mo.
@@leckyjake salamat lecky!!!
Thank you lecky for sharing your knowledge,leckyjake pwdy po bang humingi sana ng favor if ok lang,sir meron po kayong software ng lahat ng troubleshooting ng refeer container,like career,star cool,daikin etc.slmt po sir lecky jake,God bless po
Wala kami Software, puro manuals lang.
@@leckyjake slmt lecky
Interesting, for sure, but I'd kill the "music". I have to keep turning down the volume, then turning it up so I can hear your narration. Less is more!
Hello sir I'm reefer technician from ghana west Africa want to apply for a reefer technician job on vessel can please help me some tips thanks
Can we get more
Changing of compressor, evap fan, controller and how to update software will be uploaded soon.
Boss anong dahilan bakit nasira yung fan blade?? Worn bearing??
Sumayad sa body ng container
Sir plz go on more details technically ...
👍👍👍
thank sir
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much halp pls
Hello mr nice to meet you I’m ETO same like you by MSC Company pls I contact you for one urgent problem by Starcool it’s my first time same problem like it, main screen block on request data, changed already micro link and main display unit not start checked all power supply all found in order…. Tanks so much halp pls