Daikin inverter single split R410 aircon blinking | error UO, U4
Вставка
- Опубліковано 7 вер 2024
- Brand : Daikin inverter (single split)
model :
model :
error : UO, U4
UO : shortage of refrigerant in a closed stop valve or there is clogged refrigerant pipe in the system or may be a fault with the expansion valve.
U4 : communication error between indoor and outdoor units/outdoor BS units.
#bonmj #daikin #airconditioner
Thanks mr born for sharing your knowledge from your videos I learn lots
Welcome
师傅修理设备的水平很高,膜拜一下,👍
你过奖了,大家一起学习
Thank you....
Watching always from the Philippines🇵🇭
With ❤
Welcome
Thank you mr bon mj
Welcome
U are amazing men dikine are the worest especially the display on vrf hey keep forward
👍
Thanks bro
Welcome
Thanks, amazing video!
Welcome
I’m a refrigeration technician with extensive knowledge of stepper motors and valve bodies (in fact I have a battery powered valve driver).
Just a little curious why you didn’t sand off corrosion from the valve before installing new stepper (eev)?
No offense of course 🤝
Thank you brother
Welcome
You are great sir
Thanks 🙏
Thanks Sir Bon
Welcome
Good job.... well done..
Thanks 🙏
Very good!
I'm from Brazil.
Thanks
Sorry brother can I ask you how much psi R410a R 32 Panasonic Samsung thank you
R410a and R32 almost same.
Mantap Bang, saya juga seeing banget Nemuin Ac inverter,Error kode
Terima kasih master
Very useful 🙏
Thanks 🙏
Thanks sir 🙏
Most welcome
Thank you from morrocco
Welcome
@@BonMj mr Bon if you don’t mind I need video to know how to addressing master unit whit esclave to the indoor units for carrier and diking thanks a lot
Thank you Sir for your sharing. I'm from Myanmar. Nice to meet you Sir. I'm always watching, giving Like👍 and subscribing on your channel.Sir, I'm also an air-con technical engineer in my country. I want to get a job in Singapore about air conditioning. Now, I'm preparing my necessaries such as English language and diploma. Sir, Could you tell me if your company needed any one employee .Sir I hope you would reply me back. Thank you.
Thnx video. 🇹🇷✋👍🛠️🧿🤳 Bro.
Welcome bro🙏
@@BonMj thnx bro.
Buen día Maestro, feliz año. 👍
Thanks
I love this video! Do you know the impedence for the eev on a 3pcb1412-2 daikin? It has also the brown which is connected to blue 0 ohm. And my readings are strange, different from yours. Red2Orange and Red2white = 45, blue2yellow =24, orange2white=90 and all the rest infinite. Thanks!
thnaks from india
Welcome
Very good sir 👍👍👍
Thanks
hello, thank you for the video at the top, where can we buy the part please?
Thanks a lot bon
Welcome
thanks mr bon
Welcome
👍👍👍👍👍👍👍👍👍
Thanks
thanks boss
Welcome
Hi sir bon how rectify error 7113 ?
@@Kai-18v Mitsubishi VRF?
@@Kai-18v Mitsubishi VRF
Error 7113
1)incompatible pcb
2)incorrect setting
Yes PUHY EP250 YJMA HOW TO TROUBLE SHOOTING AND RECTIFY?
The equalizing pressure is over 225psi but the condenser is not starting. I get the error on start up
Hello sir, I have a Daikin 4MX80BGXV1G with an "input overcurrent" error led A blinking and led 2 and 4 on in the outdoor unit. What would be the problem? electronic board?
I have had a Daikin EcoSwing Smart R32 12K BTU for 6 months. After two days of voltage fluctuations in my house it started to show a defect (U4). Could this problem have to do with the oscillations?
Check incoming voltage
My valve is making a ticking noise and the code error is u4. I think you solve my problem. What yours opinion? Thank you.
Hi if you Google u4 it does not mention to check. The eev says Comms issue between indoor and outdoor
What made you go to the eev and find that was faulty ??
Pressure drop.
If U4 communications problems aircon wont run.
@@BonMj ok great thanksn
How much to change the motorised valve?
Post video about reactor in inverter unit
请问mitsubishi starmex single split怎样量?有六条wire的
please make video on how to check inverter pcb in daikin vrv
Hi, how to contact you or engage your service?
Can bypass the EEV system -4 daikin unit ?
Cant
how to aplly ur compeny??
i am tchnician indonesia
Can you tell me what LP mean on Daikin mini split ac 1:08 Can you tell me what LP mean on Daikin mini split ac
LP low pressure
When in R22 with capillary tube, does it mean clogged capillary , blow up pipe with N2 will it work?
Yes
Coil could do with a clean
👍
Hi Mr Bon... Is there any contact to ask u to repair... On my Daikin system 4... would wanted to learn some Skill from u...
What is your aircon problem
Hi sir bon how to check error 7113 ?
Bos duk mana?sy nk jmpa bos..nk belajar inverter
Singapore
Thanks Mr bon for sharing. Just wondering, i know daikin is a very good brand alike all japanese brands.thats what defers from chinese rubbish,the chinese split units they have no eev,guess why when you clamp meter it you find they draw 1/2 the current for the same power.
Would like to ask,the error code U4 indicate there is a system communication error and CU is not working at all.The Outdoor CU error L.E.D light/green small PCB also not light up at all.Is it still EEV,or it could be the CU PCB faulty?
May outdoor pcb faulty.
U can try off the power supply and on back, once on back u can hear tick,tick,tick sound.
If got sound may be not the outdoor pcb problem.
@@BonMj Thank you Bon.Appreciated your's advice..
@@jennylim3447 welcome
@@BonMjIf got tick tick tick sound from PCB to eev is feedback good then PCB not faulty right ?
You mean what is the problem ?
Same problem with mine. Error code U4.
Hallo master, how to fix U2...?
Daikin?
@@BonMj yes master...
@@khaerulanam5581 check voltage
systerm 1 是不是拆除eev也可以走??
如果eev是开的。
U4 不是indoor or ourdoor communications,问题??
有时候要自己判断,UO-U4 很接近,之前我同事check 是UO,reset 过后变U4.
U4-如果indoor outdoor能走,就要检查其它的。
okok 😊 thanks
Indoor 叫 outdoor 开,outdoor 不听话,不开.
也叫 communication error 咯。哈哈
Bk
Contact number boss