Daikin inverter single split R410 aircon blinking | error UO, U4

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • Brand : Daikin inverter (single split)
    model :
    model :
    error : UO, U4
    UO : shortage of refrigerant in a closed stop valve or there is clogged refrigerant pipe in the system or may be a fault with the expansion valve.
    U4 : communication error between indoor and outdoor units/outdoor BS units.
    #bonmj #daikin #airconditioner

КОМЕНТАРІ • 109

  • @ssajid2845
    @ssajid2845 2 роки тому +6

    Thanks mr born for sharing your knowledge from your videos I learn lots

    • @BonMj
      @BonMj  2 роки тому +2

      Welcome

  • @user-rc1lu6ig1q
    @user-rc1lu6ig1q 2 роки тому +2

    师傅修理设备的水平很高,膜拜一下,👍

    • @BonMj
      @BonMj  2 роки тому

      你过奖了,大家一起学习

  • @noside8469
    @noside8469 2 роки тому +1

    Thank you....
    Watching always from the Philippines🇵🇭
    With ❤

    • @BonMj
      @BonMj  2 роки тому

      Welcome

  • @mohdshahrilafizadzakaria4770
    @mohdshahrilafizadzakaria4770 Рік тому +1

    Thank you mr bon mj

  • @tadyosgu711
    @tadyosgu711 Рік тому +1

    U are amazing men dikine are the worest especially the display on vrf hey keep forward

  • @karuppaiyapvk5609
    @karuppaiyapvk5609 5 місяців тому +1

    Thanks bro

    • @BonMj
      @BonMj  5 місяців тому

      Welcome

  • @lexandrc
    @lexandrc Рік тому +1

    Thanks, amazing video!

  • @donovandavis5310
    @donovandavis5310 2 роки тому +4

    I’m a refrigeration technician with extensive knowledge of stepper motors and valve bodies (in fact I have a battery powered valve driver).
    Just a little curious why you didn’t sand off corrosion from the valve before installing new stepper (eev)?
    No offense of course 🤝

  • @soethulwin1986
    @soethulwin1986 7 місяців тому +1

    Thank you brother

    • @BonMj
      @BonMj  7 місяців тому

      Welcome

  • @siraj158
    @siraj158 2 роки тому +1

    You are great sir

    • @BonMj
      @BonMj  2 роки тому

      Thanks 🙏

  • @karimchiu7527
    @karimchiu7527 Рік тому +1

    Thanks Sir Bon

  • @asangajayalath1665
    @asangajayalath1665 2 роки тому +1

    Good job.... well done..

    • @BonMj
      @BonMj  2 роки тому

      Thanks 🙏

  • @Marcoguima45
    @Marcoguima45 2 роки тому

    Very good!
    I'm from Brazil.

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @Technology_6122
    @Technology_6122 2 роки тому +2

    Sorry brother can I ask you how much psi R410a R 32 Panasonic Samsung thank you

    • @BonMj
      @BonMj  2 роки тому

      R410a and R32 almost same.

  • @serviceacbekasi4733
    @serviceacbekasi4733 2 роки тому +1

    Mantap Bang, saya juga seeing banget Nemuin Ac inverter,Error kode

    • @BonMj
      @BonMj  2 роки тому

      Terima kasih master

  • @narayanaya5519
    @narayanaya5519 Рік тому +1

    Very useful 🙏

    • @BonMj
      @BonMj  Рік тому

      Thanks 🙏

  • @jdthakur6745
    @jdthakur6745 Місяць тому

    Thanks sir 🙏

    • @BonMj
      @BonMj  Місяць тому

      Most welcome

  • @omarleme3elem22
    @omarleme3elem22 2 роки тому +1

    Thank you from morrocco

    • @BonMj
      @BonMj  2 роки тому +1

      Welcome

    • @omarleme3elem22
      @omarleme3elem22 2 роки тому +1

      @@BonMj mr Bon if you don’t mind I need video to know how to addressing master unit whit esclave to the indoor units for carrier and diking thanks a lot

  • @linaung127
    @linaung127 2 роки тому +2

    Thank you Sir for your sharing. I'm from Myanmar. Nice to meet you Sir. I'm always watching, giving Like👍 and subscribing on your channel.Sir, I'm also an air-con technical engineer in my country. I want to get a job in Singapore about air conditioning. Now, I'm preparing my necessaries such as English language and diploma. Sir, Could you tell me if your company needed any one employee .Sir I hope you would reply me back. Thank you.

  • @karaors8970
    @karaors8970 2 роки тому +1

    Thnx video. 🇹🇷✋👍🛠️🧿🤳 Bro.

    • @BonMj
      @BonMj  2 роки тому

      Welcome bro🙏

    • @karaors8970
      @karaors8970 2 роки тому +1

      @@BonMj thnx bro.

  • @serfrigen
    @serfrigen Рік тому

    Buen día Maestro, feliz año. 👍

  • @thatcaligula
    @thatcaligula 9 місяців тому +1

    I love this video! Do you know the impedence for the eev on a 3pcb1412-2 daikin? It has also the brown which is connected to blue 0 ohm. And my readings are strange, different from yours. Red2Orange and Red2white = 45, blue2yellow =24, orange2white=90 and all the rest infinite. Thanks!

  • @hossainurrahman6700
    @hossainurrahman6700 2 роки тому

    thnaks from india

    • @BonMj
      @BonMj  2 роки тому

      Welcome

  • @priyeshsingh2507
    @priyeshsingh2507 2 роки тому

    Very good sir 👍👍👍

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @elmehdibouhajda3452
    @elmehdibouhajda3452 Рік тому +1

    hello, thank you for the video at the top, where can we buy the part please?

  • @16valve64
    @16valve64 2 роки тому

    Thanks a lot bon

    • @BonMj
      @BonMj  2 роки тому

      Welcome

  • @juruteknik6436
    @juruteknik6436 2 роки тому

    thanks mr bon

    • @BonMj
      @BonMj  2 роки тому

      Welcome

  • @Salmansalman-eb1mr
    @Salmansalman-eb1mr 10 місяців тому

    👍👍👍👍👍👍👍👍👍

    • @BonMj
      @BonMj  10 місяців тому

      Thanks

  • @md.imranhossain1892
    @md.imranhossain1892 2 роки тому +1

    thanks boss

    • @BonMj
      @BonMj  2 роки тому +1

      Welcome

    • @Kai-18v
      @Kai-18v 2 роки тому +1

      Hi sir bon how rectify error 7113 ?

    • @BonMj
      @BonMj  2 роки тому

      @@Kai-18v Mitsubishi VRF?

    • @BonMj
      @BonMj  2 роки тому +1

      @@Kai-18v Mitsubishi VRF
      Error 7113
      1)incompatible pcb
      2)incorrect setting

    • @Kai-18v
      @Kai-18v 2 роки тому

      Yes PUHY EP250 YJMA HOW TO TROUBLE SHOOTING AND RECTIFY?

  • @donovangayle1119
    @donovangayle1119 7 місяців тому +1

    The equalizing pressure is over 225psi but the condenser is not starting. I get the error on start up

  • @christianthrash
    @christianthrash Рік тому +1

    Hello sir, I have a Daikin 4MX80BGXV1G with an "input overcurrent" error led A blinking and led 2 and 4 on in the outdoor unit. What would be the problem? electronic board?

  • @sanguedodragao
    @sanguedodragao 7 місяців тому +1

    I have had a Daikin EcoSwing Smart R32 12K BTU for 6 months. After two days of voltage fluctuations in my house it started to show a defect (U4). Could this problem have to do with the oscillations?

    • @BonMj
      @BonMj  6 місяців тому

      Check incoming voltage

  • @ruimvp
    @ruimvp Рік тому +1

    My valve is making a ticking noise and the code error is u4. I think you solve my problem. What yours opinion? Thank you.

  • @robgraham1204
    @robgraham1204 2 роки тому +2

    Hi if you Google u4 it does not mention to check. The eev says Comms issue between indoor and outdoor
    What made you go to the eev and find that was faulty ??

    • @BonMj
      @BonMj  2 роки тому

      Pressure drop.
      If U4 communications problems aircon wont run.

    • @robgraham1204
      @robgraham1204 2 роки тому +1

      @@BonMj ok great thanksn

  • @fookkwongchin9454
    @fookkwongchin9454 Рік тому +1

    How much to change the motorised valve?

  • @narayanaya5519
    @narayanaya5519 Рік тому +1

    Post video about reactor in inverter unit

  • @Wilsonchan31
    @Wilsonchan31 2 роки тому +1

    请问mitsubishi starmex single split怎样量?有六条wire的

  • @hossainurrahman6700
    @hossainurrahman6700 2 роки тому

    please make video on how to check inverter pcb in daikin vrv

  • @normanhaled4843
    @normanhaled4843 4 місяці тому +1

    Hi, how to contact you or engage your service?

  • @peramaraj2763
    @peramaraj2763 11 місяців тому +1

    Can bypass the EEV system -4 daikin unit ?

    • @BonMj
      @BonMj  11 місяців тому

      Cant

  • @saifulaus2867
    @saifulaus2867 Рік тому +1

    how to aplly ur compeny??
    i am tchnician indonesia

  • @donovangayle1119
    @donovangayle1119 8 місяців тому +1

    Can you tell me what LP mean on Daikin mini split ac 1:08 Can you tell me what LP mean on Daikin mini split ac

    • @BonMj
      @BonMj  7 місяців тому

      LP low pressure

  • @mymusic-tp1bh
    @mymusic-tp1bh 2 роки тому

    When in R22 with capillary tube, does it mean clogged capillary , blow up pipe with N2 will it work?

  • @Bencrzn
    @Bencrzn Рік тому +1

    Coil could do with a clean

  • @TanTongTuck-ee6fx
    @TanTongTuck-ee6fx Рік тому +1

    Hi Mr Bon... Is there any contact to ask u to repair... On my Daikin system 4... would wanted to learn some Skill from u...

    • @BonMj
      @BonMj  Рік тому

      What is your aircon problem

  • @Kai-18v
    @Kai-18v 2 роки тому +1

    Hi sir bon how to check error 7113 ?

  • @gierschannel5858
    @gierschannel5858 5 місяців тому +1

    Bos duk mana?sy nk jmpa bos..nk belajar inverter

    • @BonMj
      @BonMj  4 місяці тому

      Singapore

  • @reubenbugeja4066
    @reubenbugeja4066 2 роки тому +1

    Thanks Mr bon for sharing. Just wondering, i know daikin is a very good brand alike all japanese brands.thats what defers from chinese rubbish,the chinese split units they have no eev,guess why when you clamp meter it you find they draw 1/2 the current for the same power.

  • @jennylim3447
    @jennylim3447 Рік тому

    Would like to ask,the error code U4 indicate there is a system communication error and CU is not working at all.The Outdoor CU error L.E.D light/green small PCB also not light up at all.Is it still EEV,or it could be the CU PCB faulty?

    • @BonMj
      @BonMj  Рік тому

      May outdoor pcb faulty.
      U can try off the power supply and on back, once on back u can hear tick,tick,tick sound.
      If got sound may be not the outdoor pcb problem.

    • @jennylim3447
      @jennylim3447 Рік тому +1

      @@BonMj Thank you Bon.Appreciated your's advice..

    • @BonMj
      @BonMj  Рік тому

      @@jennylim3447 welcome

    • @peramaraj2763
      @peramaraj2763 11 місяців тому

      ​@@BonMjIf got tick tick tick sound from PCB to eev is feedback good then PCB not faulty right ?

    • @peramaraj2763
      @peramaraj2763 11 місяців тому

      You mean what is the problem ?

  • @ctzaimr
    @ctzaimr Рік тому

    Same problem with mine. Error code U4.

  • @khaerulanam5581
    @khaerulanam5581 2 роки тому +1

    Hallo master, how to fix U2...?

    • @BonMj
      @BonMj  2 роки тому

      Daikin?

    • @khaerulanam5581
      @khaerulanam5581 2 роки тому +1

      @@BonMj yes master...

    • @BonMj
      @BonMj  2 роки тому

      @@khaerulanam5581 check voltage

  • @janshaw5472
    @janshaw5472 2 роки тому

    systerm 1 是不是拆除eev也可以走??

    • @BonMj
      @BonMj  2 роки тому

      如果eev是开的。

  • @janshaw5472
    @janshaw5472 2 роки тому

    U4 不是indoor or ourdoor communications,问题??

    • @BonMj
      @BonMj  2 роки тому +1

      有时候要自己判断,UO-U4 很接近,之前我同事check 是UO,reset 过后变U4.
      U4-如果indoor outdoor能走,就要检查其它的。

    • @janshaw5472
      @janshaw5472 2 роки тому +1

      okok 😊 thanks

    • @alvinquek8591
      @alvinquek8591 Рік тому

      Indoor 叫 outdoor 开,outdoor 不听话,不开.
      也叫 communication error 咯。哈哈

  • @bkairconditioner
    @bkairconditioner 2 роки тому +1

    Bk

  • @Jaya-vi6xq
    @Jaya-vi6xq Рік тому +1

    Contact number boss