How to Calculate Motor Efficiency | Formula & Savings Guide

Поділитися
Вставка
  • Опубліковано 30 січ 2025

КОМЕНТАРІ • 6

  • @jillwallace7725
    @jillwallace7725 7 місяців тому

    Thanks Keith!

  • @WNAZ-WALA
    @WNAZ-WALA 3 місяці тому

    Thanks for analysis

  • @linossinkala7840
    @linossinkala7840 7 місяців тому +1

    Thankyou sir

  • @rajeshgummidi235
    @rajeshgummidi235 7 місяців тому

    Hi, if we connect motor either delta or star with vfd what are the differences between them

    • @emotorsdirect
      @emotorsdirect  7 місяців тому +1

      Thanks for the question. The difference between wye or delta configuration is how voltage is expressed across the windings and thus how current is taken from the supply. The motor as a system sees a different voltage, as the delta rating is lower than the wye rating but the windings see the same voltage and current. Essentially delta/wye allow you to connect different supply voltages to the motor while expressing the same voltage across each individual winding. This is what allows for 230/460V dual voltage motors.
      Hope this answers your question, thanks for your comment.

    • @rajeshgummidi235
      @rajeshgummidi235 7 місяців тому

      @@emotorsdirect thank you very much