Baldor Explosion Proof Motors | Class 1 Division 1 Hazardous Location Motors
Are you in an industry where safety and reliability are non-negotiable? Class 1 Division 1 explosion proof motors are critical in hazardous locations.
📌 In this video, we’ll introduce you to the Baldor-Reliance Explosion-Proof Motors by ABB. Designed for hazardous environments, these motors provide the protection you need while maintaining efficiency and reliability. Whether you're working in chemical plants, oil refineries, or other explosive-risk areas, these motors ensure safety without compromising performance. Watch now to learn how these motors can keep your operations safe and running smoothly!
0:00 Introducing Baldor-Reliance explosion proof motors
0:23 Where are Baldor motors manufactured
0:31 Certifications for Baldor XP motors
0:42 Why are explosion proof motors required in hazardous locations?
1:04 Extra safety features of the Baldor explosion proof motor
1:24 Are Baldor XP motors VFD rated?
1:46 Where to buy Baldor explosion proof motors in Canada?
📌 Shop Baldor Motors: www.emotorsdirect.ca/motors/baldor
📚 Learn More About Hazardous Locations: www.emotorsdirect.ca/knowledge-center/article/definitions-for-hazardous-locations-in-north-america
Sync ID: MB01BQRSV2YFSFE
#abb #explosionproof #electricmotor #industrial #motor
Переглядів: 72

Відео

Brook Crompton Farm Duty Motors | Reliable Solutions for Farmers
Переглядів 69День тому
Finding the right motor for your farm equipment can be challenging, especially when OEM motors are discontinued or hard to source. At eMotors Direct, we make it simple-match your motor specs, and you’ll find a reliable replacement. In this video : 0:00 How to find replacements for OEM farm equipment? 0:22 How durable are these Brook Crompton Farm Duty motors? 0:42 What does thermal overload pro...
Brook Crompton Aftermarket HVAC Motors | OEM Replacement Motors for Furnaces and Air Conditioners
Переглядів 11821 день тому
Looking for a reliable HVAC motor replacement for your furnace or air conditioner? In this video, Keith introduces the Brook Crompton single-phase HVAC motors, designed for easy installation and reliable performance. Whether you're replacing a furnace blower or condenser fan motor, these motors offer a cost-effective solution with excellent protection features. Watch to learn more about their k...
Baldor Washdown Motors | Stainless Steel Electric Motors
Переглядів 1,8 тис.21 день тому
In this video, we are exploring the Baldor-Reliance Food Safe Washdown Motors by ABB, the ultimate solution for food and beverage manufacturing environments. Designed for tough, high-pressure washdowns and harsh cleaning conditions, these motors help prevent food contamination and minimize downtime in your operations. Proudly made in North America, these motors are engineered to meet the highes...
Baldor Close-Coupled Pump Motors | Available at eMotors Direct
Переглядів 1,1 тис.Місяць тому
Discover the durability and performance of Baldor-Reliance close-coupled pump motors with Keith. Whether replacing a failed OEM unit or building a custom skid, these pump motors are engineered to handle demanding commercial and industrial applications. 00:00 Introducing Baldor close-coupled pump motors 00:22 What makes the Baldor pump motors so versatile? 00:58 What service factor are the Baldo...
Baldor IEEE 841 Motors | Available at eMotors Direct
Переглядів 3,5 тис.Місяць тому
Are you tired of motor failures in harsh industrial environments? Are you looking for a severe duty motor that can handle the pressure? In this video, Keith introduces the Baldor-Reliance IEEE 841 severe duty motors, built by ABB to tackle the toughest conditions while maximizing uptime and ensuring safety. Here’s what you’ll discover: 0:00 Introducing Baldor IEEE841 Motors 0:25 Why are these m...
Baldor Farm Duty Motors | Available at eMotors Direct
Переглядів 4,5 тис.Місяць тому
Are you looking for a motor that thrives in demanding agricultural conditions? In this video, we’re showcasing Baldor Farm Duty Motors-a trusted choice for agricultural applications across Canada. Built to withstand harsh environments, these motors deliver dependable performance, whether on a small family farm or a large-scale commercial operation. Chapters: 0:00 Introducing Baldor Farm Duty Mo...
Brook Crompton General Purpose Motors | Available at eMotors Direct
Переглядів 4,5 тис.Місяць тому
Are you looking for versatile, reliable, and cost-effective motors for industrial or commercial use? In this video, we’ll answer all your questions about Brook Crompton General Purpose Motors and why they’re the ideal choice for your applications. In this video: 0:00 What makes Brook Crompton motors so versatile? 0:40 What materials are used for these Brook Crompton General Purpose motors? 0:56...
Resolve VFD Fault Codes | Step By Step Troubleshooting
Переглядів 2 тис.4 місяці тому
Watch this video for a step-by-step guide to resolve VFD fault codes. We cover voltage faults, current faults, and overheating faults and specific system messages on the TECO Westinghouse A510 VFD. Tony MacDonald gives us his recommendations for where to start when troubleshooting error codes on your VFD. 00:00 Introduction 00:28 What is a VFD Fault Code 00:50 Voltage Fault Codes 02:43 Current ...
A510 TECO Westinghouse VFD | Quick Start Guide
Переглядів 8934 місяці тому
Welcome to our A510 Quick Start Guide for the TECO Westinghouse A510 Drive. In this video, we’ll provide you with essential information to get your drive up and running quickly. Whether you're looking for the A510 TECO Westinghouse manual, a basic configuration tutorial, or need to complete a factory reset, you’ve come to the right place. What You'll Learn: 00:00 Introduction 01:08 Drive Port &...
F510 TECO Westinghouse VFD | Quick Start Guide
Переглядів 8264 місяці тому
Welcome to our F510 Quick Start Guide for the TECO Westinghouse F510 Drive! In this video, we’ll provide you with essential information to get your drive up and running quickly. Whether you're looking for the F510 TECO Westinghouse manual, a basic configuration tutorial, or need to complete a factory reset, you’ve come to the right place. 00:00 Introduction 01:02 Ports and Terminals Overview 02...
E510 TECO Westinghouse VFD | Quick Start Guide
Переглядів 1,3 тис.4 місяці тому
Welcome to our TECO E510 Quick Start Guide. In this video, we'll walk you through the E510 manual basics, including keypad setup, inputting your motor data, configuring basic parameters, and performing a factory reset. Whether you're new to the E510 or looking for a refresher, this programming tutorial is designed to help you get the most out of your TECO Westinghouse E510 VFD. What You'll Lear...
Happy International Puppy Day from eMotors Direct!
Переглядів 765 місяців тому
Happy International Puppy Day from eMotors Direct!
Electric Motor Capacitors | Available at eMotors Direct
Переглядів 4176 місяців тому
Are you looking for a replacement permanent split capacitor, run capacitor, or starting capacitor? Shop hundreds of options at eMotors Direct. Capacitors are a wearable component and will deteriorate over time. They can be replaced upon failure, or as part of your preventative maintenance program. To confirm why your capacitor failed, or if it’s close to failure, check out our tutorial. We cove...
FAG Bearings by Schaeffler | Available at eMotors Direct
Переглядів 4126 місяців тому
Is your motor squealing or do you hear grinding noises? It may be time to replace the bearing. Bearing failure is a leading cause of electric motor downtime. They minimize friction and support the motor shaft, making them crucial for optimal performance. When replacing your bearing, find the catalogue number on the side of the bearing or consult your motor nameplate. Ensure you select the ideal...
Mobil Polyrex™ EM Motor Grease | Available at eMotors Direct
Переглядів 4286 місяців тому
Mobil Polyrex™ EM Motor Grease | Available at eMotors Direct
How to Calculate Motor Efficiency | Formula & Savings Guide
Переглядів 4577 місяців тому
How to Calculate Motor Efficiency | Formula & Savings Guide
Introduction to VFD Troubleshooting | Where to Start?
Переглядів 4 тис.7 місяців тому
Introduction to VFD Troubleshooting | Where to Start?
How to Lubricate Electric Motor Bearings (Part 2)
Переглядів 2,3 тис.7 місяців тому
How to Lubricate Electric Motor Bearings (Part 2)
Lafert Electric Motors | IEC Metric Motors
Переглядів 3857 місяців тому
Lafert Electric Motors | IEC Metric Motors
Can you run a 3 phase motor on single-phase power? (Yes! Learn How)
Переглядів 12 тис.7 місяців тому
Can you run a 3 phase motor on single-phase power? (Yes! Learn How)
How to Replace a Furnace Blower Motor | Every Step Explained
Переглядів 10 тис.7 місяців тому
How to Replace a Furnace Blower Motor | Every Step Explained
How to Test a Furnace Blower Motor | Easy Guide
Переглядів 10 тис.7 місяців тому
How to Test a Furnace Blower Motor | Easy Guide
NEMA vs IEC Motors: Frame Sizes, Standards, and Replacement
Переглядів 1,9 тис.7 місяців тому
NEMA vs IEC Motors: Frame Sizes, Standards, and Replacement
VFD Minimum Speeds: How Slow Can You Safely Run Your Motor
Переглядів 1,8 тис.8 місяців тому
VFD Minimum Speeds: How Slow Can You Safely Run Your Motor
IEEE 841 Electric Motors
Переглядів 4518 місяців тому
IEEE 841 Electric Motors
Electric Motor Gear Ratio Calculator
Переглядів 2798 місяців тому
Electric Motor Gear Ratio Calculator
Comment remplacer un condensateur de moteur
Переглядів 2,7 тис.9 місяців тому
Comment remplacer un condensateur de moteur
What is the Service Factor of a Motor?
Переглядів 2,9 тис.9 місяців тому
What is the Service Factor of a Motor?
Comment changer la direction d’un moteur CC
Переглядів 1299 місяців тому
Comment changer la direction d’un moteur CC

КОМЕНТАРІ

  • @PreachDaBeast
    @PreachDaBeast 7 годин тому

    What is the load

  • @407donkridnfoodcritic5
    @407donkridnfoodcritic5 День тому

    Mft Mr Williams class. 2025

  • @407donkridnfoodcritic5
    @407donkridnfoodcritic5 День тому

    Mr Williams class mft 2025 let’s go

  • @ozcansakarya6991
    @ozcansakarya6991 2 дні тому

    It gives a short circuit fault, what is the source? Most of our machines have this driver, almost all of them give a short circuit fault but we cannot find the fault. Can you help me please, thank you very much in advance.

    • @emotorsdirect
      @emotorsdirect 2 дні тому

      The 'SC' fault code could mean either a short circuit or a ground fault. This could be due to damaged motor insulation or wire damage/deterioration. I'd start with checking +testing the motor wiring.

  • @abdulsalamarifvkarif7288
    @abdulsalamarifvkarif7288 2 дні тому

    Very simple, informative high value info regarding greasing. ❤

  • @TevisC
    @TevisC 4 дні тому

    Considering going 3phase for my next model train. (YT search "Train Mountain" for context) I'm not concerned about over heating a slow turning traction motor. My 3/4hp 24v 56c 1800rpm motor has never been hot to the touch, even when producing about 1.25 hp. High load duty cycles are generally fairly short. Questions: 1. Can VFD use remote potentiometer for speed and toggle switch for direction? 2. will VFD produce smooth rotation at low speeds? 3. Can VFD do dynamic braking? How is this energy dissipated? Grid resistor? Using 3 phase has its appeal because: 1. Generation of 120v single phase can be done with compact - quiet inverter generator. 2. wheel slippage can be more easily managed vs DC motor tend to speed up. 3 phase motors are frequency locked (to an extend) to a speed. 3. easier to maintain desired travel speed, as frequency controls speed vs voltage of DC system. Sensing system in VFD can limit torque to prevent overload. 4. If braking is dynamic, and can be shunted to load resistor of sufficient size? Down hill momentum can be easily controlled by turn of dial instead of on-off with DC system. 5. Using motor to hold train still for brief periods vs having to engage mechanical brakes would be a great improvement.

    • @emotorsdirect
      @emotorsdirect 4 дні тому

      Sounds like you have quite the train set up! Answers to your questions below. (1) Yes (2) Yes, however, low-speed rotation depends on the type of VFD and the motor used (3) Yes, if your VFD has a dynamic braking resistor

  • @linossinkala7840
    @linossinkala7840 6 днів тому

    Thankyou so much for the knowledge

  • @SamwelMuigai-c9v
    @SamwelMuigai-c9v 8 днів тому

    Hi sir. I have an issue with alarm on my inverter

    • @emotorsdirect
      @emotorsdirect 8 днів тому

      Hi Samwel, I do have a fault code troubleshooting video that you may find helpful: ua-cam.com/video/NgrpYYsMXRg/v-deo.htmlsi=Km604ysjWY9a8afr

  • @tommogaka6627
    @tommogaka6627 9 днів тому

    Good teaching ,keep it up

    • @emotorsdirect
      @emotorsdirect 8 днів тому

      Thanks Tom! You might like this one too: ua-cam.com/video/PjeDqPBp0RA/v-deo.htmlsi=bIcW0jFX79sJpjQG

  • @austinrojoh
    @austinrojoh 11 днів тому

    Well explained sir

  • @_elcaballero
    @_elcaballero 13 днів тому

    Hey Keith, Younger brother replaced belt on my air compressor but over tightened belt, said it went on for maybe a minute and over load ripped but now I feel the motor heating up and I got a faint burning smell so I shut it off. Took it apart, visually everything looks ok. Also tested a few things with multimeter, Cap is within uF spec still, its getting sufficiemte voltage at source no drop or anything. What do you think? I have 4 new bearings on way 2 for motor and just gonna replace both in my pump because I noticed the fly wheel having more resistance than before this issue so idk if those could have went too. Im hoping bearings are my issue. Almost forgot ran motor with no load and no issues runs as it should. Appreciate your help/knowledge Great channel btw! Thanks in advance.

    • @emotorsdirect
      @emotorsdirect 10 днів тому

      Sounds like you did a good job troubleshooting so far. Even though everything visually looks okay and the capacitor tested fine, there still may be an issue based on the overheating and smell. There could be bearing damage from the tightened belt. I'd try spinning the shaft by hand to see if there's any resistance. You could also test the windings if you haven't already. Here's a step by step guide: ua-cam.com/video/19zIZ7sTEhQ/v-deo.htmlsi=Mbojtiem8kVRTKSf&t=83.

    • @_elcaballero
      @_elcaballero 10 днів тому

      @ there is quite a bit of resistance but only at a certain point during the rotation That’s what I was wondering about most because I do notice that it was more than before this happened. Will look at your video now and see what I get.

    • @emotorsdirect
      @emotorsdirect 10 днів тому

      @@_elcaballero If there is resistance while turning the shaft, its probably a bearing issue. Could be damaged bearing races or ball. Or it could be as simple as contaminated lubrication. How does the grease look inside the bearing? Do you notice any debris/sand/grit?

  • @GR-wp8et
    @GR-wp8et 14 днів тому

    Didn’t show ever step , just say the step number and explained but didn’t show how to do it .

    • @emotorsdirect
      @emotorsdirect 13 днів тому

      Are you looking for more info on one of these steps? Every furnace and motor will be a little different, so this is a fairly broad guide.

  • @dicksonntibukigwa4931
    @dicksonntibukigwa4931 14 днів тому

    Subtitles would sound better.

  • @colin5064
    @colin5064 16 днів тому

    Excellent video all you need to know

  • @devilsadvocate783
    @devilsadvocate783 18 днів тому

    COMPANION BALL BEARING A.C. MOTOR TYPE SP H.P. 1/4 110 VOLTS 60 CYC. 4 AMPS. 3450 R.P.M.MODEL 115.5107 M28 Will this work with a VFD or is there something else I can use? I need it to slow down to around 800 to 1000 rpm

    • @emotorsdirect
      @emotorsdirect 17 днів тому

      Based on the voltage rating, this is a single phase motor and VFDs are primarily used for three phase motors. I'm not familiar with the motor catalogue number that you shared and I couldn't find any details on it online. I'd suggest reaching out to a local supplier and they should be able to assist you. In these cases where speed control is required, our customers often upgrade to a three phase motor.

  • @garybouwman2157
    @garybouwman2157 21 день тому

    Great information. I could have really used this last year. I wish I would have checked here first before calling out the HVAC folks. I could have easily done it myself.

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      Thanks Gary! Give us a call if you ever need a hand.

  • @Uw2u33u3u3u
    @Uw2u33u3u3u 21 день тому

    Baldor was great back in the day but now they are overpriced.

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      Depends what you're looking for. If you're looking for a budget option, Baldor is not your motor. But, if reliability is important, Baldor is a solid choice. Speaking just on our own numbers, the Baldor's have a lower than average warranty claim-rate and when properly maintained and operated, pretty rare to see issues with these. Thanks for the comment - more content coming soon.

  • @Uw2u33u3u3u
    @Uw2u33u3u3u 21 день тому

    I've noticed some manufacturers like World Wide Electric, have started removing the zerk fittings on motors 10hp and under. Doesn't matter if its TEFC OR ODP. They said people are destroying bearings by over greasing.

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      I've come across this too from time to time with more than one brand. If there is a grease zerk, you would assume it is a greaseable bearing, but not always. If a motor under 10HP has a grease zerk, never a bad idea to check the manual to confirm.

  • @chelsea08FC
    @chelsea08FC 25 днів тому

    Very informative. Thanks 😊👍🏾

  • @mianwaseemakhter7680
    @mianwaseemakhter7680 27 днів тому

    Excellent, I have a question if In DC motor, brush holder creating arching/sparking then how to fix it? by rotating the brushes ahead in the direction of rotation or rotating brushes opposite in the direction of rotation? Please advise. Thank you! (Note: although brushes are fine)

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      Hey Mian, a slight spark as the motor starts up is normal. If it's continuing to spark while the motor runs, it could be an issue with your brush position, there could be an issue with the commutator surface, it could be overloading, or any other number of things. Hard to diagnose without seeing it! Good luck.

    • @mianwaseemakhter7680
      @mianwaseemakhter7680 20 днів тому

      @@emotorsdirect appreciate for you advise sir

  • @MsLorisM
    @MsLorisM 28 днів тому

    I have an old Craftsman table saw. The motor hums and trips the breaker. The capacitor is 110 VAC, 216-259 MFD. size is 1-7/16 by 2-3/4 The one on your web site has dual blade terminals. item Packard PMJ216. The old one has only two terminals. Is that a problem?

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      The dual blade terminals are just a design choice by the manufacturer to allow for easier or more flexible wiring configurations. They are not an issue as long as you connect the wires correctly. If you're still unsure, feel free to contact our team at customerservice@emotorsdirect.ca.

  • @upuldhanushkagajanayake2719
    @upuldhanushkagajanayake2719 Місяць тому

    Wooow ❤❤❤

  • @AntoinetteAmaza
    @AntoinetteAmaza Місяць тому

    Bonsoir technicien Comment réparer un moteur qui provoque le court-circuit fréquemment dû à un surcharge ?

    • @emotorsdirect
      @emotorsdirect 28 днів тому

      Bonjour Anntoinette, vous trouverez peut-être cette vidéo utile pour éviter les surcharges, cependant, elle est en anglais: ua-cam.com/video/jG9XGuVan-o/v-deo.html

  • @matto7909
    @matto7909 Місяць тому

    I forgot to take a pic before disconnecting old one. How do i determine how to connect wires now? Any video or reading recommended? I have that situation currently with a spa pump motor start capacitor (2 terminals, not 3)

    • @emotorsdirect
      @emotorsdirect 28 днів тому

      Hi Matt, look at the motor's wiring diagram. This is often printed on the motor itself or in the manual. If the diagram isn’t available, note the motor's labels for the terminals (often marked as L1, L2, Start, Run, or Common).

  • @zoltanmolnar4688
    @zoltanmolnar4688 Місяць тому

    After few use, my DeWalt DW733 does this : ua-cam.com/users/shortsJxh-c_tlbWw?si=0pV_R2KCWj8eDBaw Is it normal?

    • @emotorsdirect
      @emotorsdirect 28 днів тому

      Hi Zoltán, when the motor starts, a large surge of electrical current flows through the brushes and commutator. This can produce noticeable sparks. Because the spark is noticeable only when the motor starts, and assuming there is no burning smell, I don't think this is cause for worry. Dewalts aren't my area of expertise but I hope this helps.

    • @zoltanmolnar4688
      @zoltanmolnar4688 27 днів тому

      Thank you!

  • @WNAZ-WALA
    @WNAZ-WALA Місяць тому

    Thanks for

  • @catfish340d
    @catfish340d Місяць тому

    Question my start capacitor is 110vac. My auger motor is du voltage I'm running it on high voltage 220. My capacitor went out. Do you feel that had any to do with it?

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      In a motor running on 220V, the voltage across the start capacitor can exceed 110V, especially due to transient spikes or back EMF generated during motor startup. You could try a 220v capacitor instead, which you can likely find for under $20: www.emotorsdirect.ca/parts/capacitors?nominal-voltage=220~250V&product-subsubcategory=Start-Capacitor

  • @ansarisahab6310
    @ansarisahab6310 Місяць тому

    Teco F510 SEP1 FAULT

    • @emotorsdirect
      @emotorsdirect Місяць тому

      Hi Ansari, I don't see this fault code in the manual. What's the catalogue number on your drive?

  • @ansarisahab6310
    @ansarisahab6310 Місяць тому

    Sir SEP 1 FOULT SOLVE

    • @emotorsdirect
      @emotorsdirect Місяць тому

      Hi Ansari, I don't see this fault code in the manual. What's the catalogue number on your drive?

  • @autonexuz
    @autonexuz Місяць тому

  • @linossinkala7840
    @linossinkala7840 Місяць тому

    Thankyou for information

    • @emotorsdirect
      @emotorsdirect 20 днів тому

      Thanks Linos! More content coming soon.

  • @dmlmediaug5700
    @dmlmediaug5700 Місяць тому

    My concrete mixer motor has wired noise sir, what do you think come be the cause, is working well but sometimes it gives out some little smoke

    • @emotorsdirect
      @emotorsdirect Місяць тому

      It could be overloading. Ensure the load capacity of the mixer does not exceed the motor's rating. Reduce the batch size if necessary and allow the motor to cool between uses.

  • @omaral-kofahi8308
    @omaral-kofahi8308 Місяць тому

    Hello, I use TECO A510 in my motor applications and they run great. I used Modbus for communications, start, stop ... Is there a Watchdog or Keep-Alive function for the TECO A510? That is, automatically stop the motor if the communications with the VFD is lost? Thank you, Omar

    • @emotorsdirect
      @emotorsdirect Місяць тому

      Take a look at parameters 09-06, 09-07, 09-08, and 09-09. As far as I read and understand, 09-07 we tell the VFD what we want it to do when there is a communication failure. And then the other parameters are just the limitations around when the VFD decides there is a communication issue. Hope this helps!

    • @omaral-kofahi8308
      @omaral-kofahi8308 Місяць тому

      @@emotorsdirect Thank you very much. It will also help if the VFD receives a Keep-Alive signal from the controller. Any directions where to look for that will be very much appreciated. Thank you.

  • @jaymark6723
    @jaymark6723 Місяць тому

    Great!

  • @decoder-le6vg
    @decoder-le6vg Місяць тому

    nice presentation on what could be terribly dull content. He mad it interesting and I learned a few things. Thats the important part!

  • @looseslacks9063
    @looseslacks9063 Місяць тому

    Hi keith, awesome video. I'd like to know if a vfd is suitable for my 3phase, 4kw, 2900rpm reciprocating compressor? I think I should use a soft starter but those are hard to find where am at. Main reason for the installation is to reduce the starting amps draw of the motor as it will be connected to (3) 10kw inverters with a 15kw lithium battery. Nnoruka from Enugu, Nigeria I also have a 7.5kw - 11kw inverter I'll like to install on a 3phase, 11kw, 1400rpm reciprocating compressor if the first installation works out fine. Altitude and temperature are within spec. Waiting for your experienced insight. Thank you

    • @emotorsdirect
      @emotorsdirect Місяць тому

      Thanks for watching! Posting new content soon so stay tuned. Some things to consider when selecting a VFD (1) torque - depending on your compressor application, you may need a variable torque or constant torque rating. A reciprocating compressor would typically need constant torque. (2) cooling - depending on how slow you want to turn the motor, it may not be able to cool itself properly. Check that the motor is inverter rated and what the minimum speed recommendation is, per the manufacturer guidelines. I'm not familiar with the electrical codes in Nigeria, so I would consult that as well. Good luck!

    • @looseslacks9063
      @looseslacks9063 Місяць тому

      @emotorsdirect Thank you!

  • @michaelhazell5317
    @michaelhazell5317 Місяць тому

    Hi have you done a video about what to do when changing grease types in a bearing or motor?

    • @emotorsdirect
      @emotorsdirect Місяць тому

      Hi Michael, no I haven't done a video on this yet. What's the use case?

  • @linossinkala7840
    @linossinkala7840 2 місяці тому

    Thankyou

  • @smokeweave3925
    @smokeweave3925 2 місяці тому

    but how it works inside the motor? lets say the speed is low how does the motor keep up with the load?does the voltage or the frequency maintains the torque

  • @bjac36
    @bjac36 2 місяці тому

    Would like to see video with cable specs between vfd and motor. Thanks.

  • @danielteyehuago1633
    @danielteyehuago1633 2 місяці тому

    3:34 Wow! Great video

  • @Andrew-vb9bm
    @Andrew-vb9bm 2 місяці тому

    Thanks!

  • @adrewfis925
    @adrewfis925 2 місяці тому

    1 Surumā vacana thiyō, ra vacana paramēśvarasam̐ga thiyō, ra vacana paramēśvara hunuhunthyō. 2 Uhām̐ surumā paramēśvarasam̐ga hunuhunthyō. 3 Sabai thōka uhām̐dvārā banā'i'ēkā thi'ē, ra uhām̐ binā banā'i'ēkō kunai pani kurā banā'i'ēkō thi'ēna. 4 Uhām̐mā jīvana thiyō, ra jīvana mānisaharūkō jyōti thiyō. 5 Ani jyōti andhakāramā camkancha, ra andhakāralē yasalā'ī bujhēna. Yūhannā 1:1-5 Yēśūlē āphūlā'ī mahān ma hum̐sam̐ga tulanā garnuhuncha - 54 yēśūlē javāpha dinubhayō, "yadi mailē āphūlā'ī sam'māna garēṁ bhanē, mērō sam'māna kēhī chaina. Yō mērō pitā hunuhuncha jasalē malā'ī ādara garnuhuncha, jasakō bārēmā tapā'īṁ bhannuhuncha ki uhām̐ tapā'īṅkō bhagavāna hunuhuncha. 55 Tāpani timīharūlē uhām̐lā'ī cinēkā chainau, tara ma uhām̐lā'ī cinchu. Ra yadi mailē'ma uhām̐lā'ī cindina' bhana bhanē, ma tapā'īṁ jastai jhūṭō hunēchu; tara ma uhām̐lā'ī cinchu ra uhām̐kō vacana pālana garchu. 56 Timrā pitā abrāhāma mērō dina dēkhēra harṣita bha'ē, ra tyō dēkhēra khusī bha'ē.” 57 Taba yahūdīharūlē uhām̐lā'ī bhanē, “timī ajhai pacāsa varṣakō bha'isakēkā chainau, ra kē tapā'īnlē abrāhāmalā'ī dēkhnubha'ēkō cha?” 58 Yēśūlē tinīharūlā'ī bhannubhayō, “sām̐ccai ma timīharūlā'ī bhandachu, abrāhāma hunu'aghi ma nai hum̐.” Yūhannā 8:54-58 Samācāra phlyāsa. "Ma hum̐" uhī paramēśvara hunuhuncha jasalē svarga, pr̥thvī ra tī sabai cījaharū sr̥ṣṭi garnubhayō. Mōśā ra jalirahēkō jhāḍīkō vivaraṇa paḍhnuhōs ra paramēśvaralē mōśālā'ī phira'ūnakahām̐ paṭhā'unubhayō bhannuhuncha. Utpatti 1:26 Pani paḍhnuhōs ra hērnuhōs ki sr̥ṣṭikartā kamtimā 2 bhāga hunuhuncha ra tēsrō bhāga/vyakti pahilē ullēkha gari'ēkō thiyō, pavitra ātmā gahirō satahamā ghumirahanubha'ēkō cha. \V 26 taba paramēśvaralē bhannubhayō, "hāmrō pratirūpamā mānisalā'ī hāmrō svarūpamā banā'auṁ, samudrakā māchāharū, ākāśakā paṅkṣīharū ra gā'īvastuharū, sārā pr̥thvī ra harēka kurāmāthi tinīharūlē ādhipatya pā'ōs. Pr̥thvīmā ghasranē kurā. Hāmī ra hāmrō bhannē bahuvacana sarvanāmalā'ī dhyāna dinuhōs yadi tyahām̐ sabai kurā/vyakti sr̥ṣṭi garnē ēka mātra paramēśvara hunuhuncha bhanē yasakō artha uhām̐ tri'ēka hunuhuncha jasarī yēśūlē āphnō pārthiva sēvakā'īkā varṣaharūmā bārambāra bhannubhayō. Yēśū khrīṣṭa ra pitā - 22 aba yarūśalēmamā samarpaṇakō cāḍa thiyō, ra yō jāḍō thiyō. 23 Ani yēśū mandiramā, sōlōmanakō dalānamā hiṇḍnu bhayō. 24 Taba yahūdīharūlē uhām̐lā'ī ghērē ra uhām̐lā'ī bhanē, “tapā'īnlē hāmīlā'ī kahilēsam'ma śaṅkāmā rākhnuhuncha? Yadi tapā'īṁ khrīṣṭa hunuhuncha bhanē, hāmīlā'ī spaṣṭa rūpamā bhannuhōs. 25 Yēśūlē tinīharūlā'ī javāpha dinubhayō, “mailē timīharūlā'ī bhanēkō thi'ēm̐, tara timīharū viśvāsa gardainau. Mailē mērō bubākō nāmamā garnē kāmaharū mērō sākṣī dinchan. 26 Tara timīharū viśvāsa gardainau, kinaki timīharū mērā bhēḍ'̔āharūkā hō'inau, jasarī mailē timīharūlā'ī bhanēṁ. 27 Mērā bhēḍ'̔āharūlē mērō sōra sunchan, ra ma tinīharūlā'ī cinchu, ra tinīharūlē malā'ī pachyā'um̐chan. 28 Ani ma tinīharūlā'ī ananta jīvana dinchu, ra tinīharū kahilyai nāśa hunēchainan. Na ta kasailē tinīharūlā'ī mērō hātabāṭa khōsnēcha. 29 Mērā pitā, jasalē tinīharūlā'ī malā'ī dinubha'ēkō cha, uhām̐ sabaibhandā mahān hunuhuncha. Ra kasailē tinīharūlā'ī mērō bubākō hātabāṭa khōsna sakdaina. 30 Ma ra mērā pitā ēka hauṁ.” Yūhannā 10:22-30 Pavitra ātmā - 12 “masam̐ga ajhai dhērai kurāharū chan, tara timīharūlē sahana sakdainau. 13 Yadyapi, jaba uhām̐, satyakō ātmā ā'unuhuncha, uhām̐lē tapā'īnlā'ī sabai satyamā ḍōṟyā'unuhunēcha. Kinaki uhām̐ āphnai adhikāramā bōlnuhunēchaina, tara uhām̐lē jē sunnuhuncha tyahī bōlnuhunēcha. Ani uhām̐lē timīharūlā'ī ā'unē kurāharū batā'unuhunēcha. 14Uhām̐lē malā'ī mahimā dinuhunēcha, kinaki mērō jē cha tyasabāṭa uhām̐lē timīharūlā'ī ghōṣaṇā garnuhunēcha. 15 Pitāsam̐ga bha'ēkā sabai kurāharū mērā hun. Yasailē mailē bhanēṁ ki uhām̐lē mabāṭa linuhuncha ra tapā'īlā'ī ghōṣaṇā garnuhuncha. Yūhannā 16:12-14

  • @Jay-tr3px
    @Jay-tr3px 2 місяці тому

    Hi thanks for the great video. I was just wondering. Can you put just two hot wires in a three pole overload (ex. L1✓ L2✓ L3×)??

    • @emotorsdirect
      @emotorsdirect 2 місяці тому

      Yes, you can wire two hot wires through a three-pole overload relay, but it depends on the relay's design and specifications. Ensure the relay supports two-wire operation or consider using a two-pole overload relay to avoid potential faults or improper operation.

    • @Jay-tr3px
      @Jay-tr3px 2 місяці тому

      @emotorsdirect Great thank you for your reply. I couldn't find a 2 pole overload relay handy for my project but I improvised just looping my T2 to L3 and my T1 and T2 as my output to the motor. Should be okay right?

  • @myomyintaung8355
    @myomyintaung8355 2 місяці тому

    Sir please let me know fault code ( OPbFt )

    • @emotorsdirect
      @emotorsdirect Місяць тому

      Hi Myo, this is the high pressure fault code. The feedback value of pump pressure is lower than limit of maximum flow. Check feedback signal is correct. Check if feedback value of pressure is lower than limit of maximum pressure (23-12). Find the manual here: www.emotorsdirect.ca/item/teco-f510-4250-c3-u?quantity=1&tab=downloads-tab

  • @G5Hohn
    @G5Hohn 2 місяці тому

    A compressor is not constant torque. The torque will vary with the pressure head the pump must overcome.

    • @emotorsdirect
      @emotorsdirect 2 місяці тому

      You caught me there - a lot of compressors are variable torque, especially in large industrial applications. I deal with some constant torque compressors in fixed-speed or fixed-load applications as well.

  • @WNAZ-WALA
    @WNAZ-WALA 2 місяці тому

    Thanks for mnshdhhdbsb

  • @vinzkietot8224
    @vinzkietot8224 2 місяці тому

    Question: if the VFD 1.5 KW it can work to 8 KW HVAC?

    • @vinzkietot8224
      @vinzkietot8224 2 місяці тому

      First time to install the vfd 1.5kw and hvac 8kw

    • @emotorsdirect
      @emotorsdirect 2 місяці тому

      You can consider 'horsepower' and 'kilowatts' synonymous in this video. You should size your VFD based on the motor FLA and voltage, not the horsepower (or kilowatts). But generally speaking, we can match motor horsepower to VFD horsepower (ie. 8 HP motor to 8 HP VFD), unless you have an application with a high degree of overload, in which case, you should oversize the VFD. Based on the information, I think your VFD is probably undersized for your motor.

  • @pusiachristopher136
    @pusiachristopher136 2 місяці тому

    Very informative

  • @mendozaconsultation
    @mendozaconsultation 2 місяці тому

    I have a Question. I have an old 12v motor from my van's rear bench seat that folds down. It has 2 wires that come out of it that gets its power from the car. How can i take it appart and add 2 more wire's so it can be use to get power and give power at the same time.

    • @emotorsdirect
      @emotorsdirect 2 місяці тому

      Thanks for the question. In theory, yes you could do this but it's not my area of expertise.