Injector Bypass- Downstream to Either Reel

Поділитися
Вставка
  • Опубліковано 22 жов 2024

КОМЕНТАРІ • 52

  • @pedromatosmatos1767
    @pedromatosmatos1767 14 днів тому +1

    Good ideas are good!
    I have a downstream baypasse just like this one, except the tap is on the hose. When I watched your video, an idea came to me. I have a question; in my case, I have a 1.8 orifice for a 4gpm pump. Since the downstream has a low mixing percentage, can I put another one in parallel to increase the mixing volume? Be careful, they are not one in front of the other.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  14 днів тому +1

      That's a good question. When we used a 4 GPM machine, we used a 2.1 injector and was getting about 1.25%. That's the downside to down streaming and why we moved to the AR45. Thanks

  • @PickensPowerWashing
    @PickensPowerWashing 3 місяці тому

    Love the idea and creativity! How has it worked for you? Did you stick with it or change to a different setup? I know it’s been a while now.

  • @ogFr3nzy
    @ogFr3nzy 6 місяців тому +1

    jsut to be clear, since im getting into Pressure washing, u run SH while surface cleaning? whats the point of downstreaming there? i thougth downstreaming is not strong enough for surface cleaning.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  6 місяців тому

      You should not run SH while surface cleaning. You could pre or post treat with SH. Sometimes a downstream mix will work. Thanks

  • @joegideon6730
    @joegideon6730 3 роки тому +2

    Plumbing skills are a requirement for this job for sure. Rig looks awesome! Thanks for sharing.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      Agreed. Thanks!

    • @VaJamie
      @VaJamie 3 роки тому +1

      @@allproexteriorservicesllc5338 Does True Blue work as well as the tape you mentioned?

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      @@VaJamie Yes, True Blue works very well. Just a little messy. I mainly use True Blue on my soft wash fitting due to higher concentrate of SH. Thanks

  • @enjoythesho1992
    @enjoythesho1992 Рік тому +1

    Are those 3/8 T fitting from Amazon they say they are only rated for 2800 psi?

  • @genebernal6260
    @genebernal6260 2 роки тому +1

    I have a 2 pump 2 reel setup with downstream on both. Both pumps will or could surface wash and with that being said wouldnt I want 2 bypass injectors?

  • @johnwitt586
    @johnwitt586 2 роки тому

    Man, you are always posting great content! Definitely gives you more options on the trailer!

  • @powerfulimprovements
    @powerfulimprovements 3 роки тому +1

    Great idea as usual

  • @bradclark1752
    @bradclark1752 3 роки тому

    Awesome video man! “T Rad” watching in B’ham!

  • @TheMhowi007
    @TheMhowi007 3 роки тому +2

    That blue monster is life changing. I just ordered all the parts to build that box for saop you built looking forward to that.. I just added the bypass today really pumped about that. That being said I also just ordered that three way plastic ball valve instead of using it for 2 guns I wanted to use it as a flush system for my new soap box have one line for soap/bleach then the other going strait to a water and bleach neutralizer cube

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому +1

      Awesome!! I actually have 2 3-way ball vales. One to switch between SH & water, and the other one to choose what reel to send it to. Let me know if you need any assistance with the box. Thanks

    • @TheMhowi007
      @TheMhowi007 3 роки тому +1

      Ok glad you commented cause wanted to make sure that would work gotta love upgrades! Thanks alot and will do

  • @bobodine9299
    @bobodine9299 3 роки тому +1

    This is funny seeing this video today this is the question I asked Doug Rucker why not put your Downstream injector on the whip line and put the dn10 valve on a straight path that is a smartest thing you did I believe and I asked him that question for the same reason you mention so you can do surface cleaning without losing pressure

  • @davidmaco1
    @davidmaco1 3 роки тому +1

    do you have a way to flush out the injectors??? that is what I use my three way ball valve for is to flush the injector out. you will love the by pass

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому +1

      Yes, I have another 3-way ball valve that runs to my SH and water tanks. I just switch to water and flush. The by pass is awesome for sure!! Thanks

  • @michaelc7283
    @michaelc7283 3 роки тому +1

    I think i missed something. How will you rinse the injector with water if the soap is connected. Again, i missed something. That is a pretty cool idea.
    Thanks for this video

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому +1

      I have another 3-way ball valve that is connected to my SH tank & water tank. I just switch the ball valve to water and rinse. Thanks

  • @SOB_13
    @SOB_13 2 роки тому +1

    Did you buy this all together in a kit?

  • @DumbCarGuy
    @DumbCarGuy 2 роки тому +1

    Blue Monster is much better than Tru Blue. I keep getting leaks with Tru Blue off of my 4gpm 4400psi pump. The PSI rating is terrible for Tru Blue maybe 800 or so. But nothing beats and I mean nothing beats HERON Powerseal 932. $70 for 8oz. (Ouch) But it has a 10,000 psi rating and is for hot water and steam as well. If your sick of those little drippies and we all are. This is the way to go.

  • @HouseWashingRick
    @HouseWashingRick 3 роки тому +1

    I make a small stainless steel box for the small 3 way ball valve. If anyone wants a picture of what it looks like let me know. The 3 way ball valve goes into the box and it protects it from every getting broken

  • @mattburns4407
    @mattburns4407 2 роки тому +1

    Hey bud are u on fb? How can I message u…I’m having issues since in installed the remote box…

  • @mikem6197
    @mikem6197 2 роки тому +1

    You run a 1/2” whip hose or 3/8” on the bypass? Thanks for all the help and great content!

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому

      I am running a 3/8" hose. Thanks

    • @mikem6197
      @mikem6197 2 роки тому +1

      Thank you! One more question if you don’t mind. I want to set mine up just like that. What are those on both sides of the chemical injector, just a female & male 3/8 coupler? Thanks

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому

      @@mikem6197 I used the couplers on both sides if the injector. I did use 2 adapters on the ball valve. I purchases the kit from Southside Eq. thanks

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому

      @@mikem6197 Yes just couplers. I did use nipples on the ball valve.

  • @jimmywarren6685
    @jimmywarren6685 3 роки тому +1

    I see no benefit to the bypass...that small amount of water volume increase makes almost no difference and would never be worth the cost of the bypass.

  • @mikefox7204
    @mikefox7204 3 роки тому

    🇱🇷💪💪💪🇱🇷💵💵💵