I nearly miss diagnose a boiler fault 😬

Поділитися
Вставка
  • Опубліковано 7 вер 2024

КОМЕНТАРІ • 73

  • @Heatking
    @Heatking  2 місяці тому +2

    Thank you for watching. Dont forget to like 😂❤Also I’ll be at installer show next week on the Wednesday if anyone is there, come say hello 🎉

    • @deano6017
      @deano6017 2 місяці тому

      that's a shame mate I'm going on the Thursday. great video tho

    • @Heatking
      @Heatking  2 місяці тому +1

      @deano6017 cheers Deano! There’s also a chance I might go Thursday too, but we shall see!

  • @wolvolad25
    @wolvolad25 2 місяці тому +2

    They didn’t even check that 12:29 wow 😂😂

  • @nickmarrow2645
    @nickmarrow2645 2 місяці тому +1

    Any chance you could do a video focused around starting and setting up on your own as a sole trader. Any tips from experience you can give etc! Would be very helpful for many of us out there embarking on that journey

    • @Heatking
      @Heatking  2 місяці тому +1

      Yeh Nick leave it with me mate. ♥️

  • @marktrower2267
    @marktrower2267 29 днів тому +1

    I am not a plumber but many times i have cut a rubber glove finger off and put it over to stop the leak lol 😂 😂

    • @Heatking
      @Heatking  29 днів тому +1

      @@marktrower2267 😂😂 brilliant mate!

  • @nigelmiddleton2727
    @nigelmiddleton2727 2 місяці тому +1

    Brilliant little tip regarding the blue bung for the washer! I wish the kitchen fitters in our last new build property had watched this video rather than leaving us with a flooded kitchen 😢 cheers 🍻

    • @Heatking
      @Heatking  2 місяці тому

      Thanks Nigel, to be fair. Mcalpine say it should go inside the trap, not on the outside 🤯😂

  • @johnsmart4692
    @johnsmart4692 2 місяці тому +1

    Good content , keep up the good work 😁👍

    • @Heatking
      @Heatking  2 місяці тому

      Thanks John 🙏🏽

  • @rorystudio1928
    @rorystudio1928 2 місяці тому +1

    Thanks for your teaching. It makes sense when you go through things. ☀️

    • @Heatking
      @Heatking  2 місяці тому

      Thank you very much! Sure it doesn’t make sense to everyone but I try 😂😂

  • @bluebulldog_uk
    @bluebulldog_uk 2 місяці тому +1

    New waste all day ain’t worth the time to going merchants, good shout keeping that old thermistor as well mate 👍👍

    • @Heatking
      @Heatking  2 місяці тому

      Cheers mate ♥️

  • @thegrinch295
    @thegrinch295 2 місяці тому +1

    Oh boy oh boy I’m so late to turn up on this. Just passed out from not sleeping over the weekend.
    Anyway I would’ve done exactly what u did instead of driving back and forth. That basket swap was an efficient move and it takes experience to think of that on the fly.
    Thanks Dan for another vid

    • @Heatking
      @Heatking  2 місяці тому +1

      Hey mate, don’t worry about the late reply. At least you got time to watch it. Hopefully you managed to catch up on your sleep. Thank you for your feedback on the video as always.♥️

  • @trevorjarvis3021
    @trevorjarvis3021 2 місяці тому +1

    Brilliant tips Dan.😊

  • @mcginn002
    @mcginn002 2 місяці тому +1

    I have had a few thermistors check OK out of circuit but go haywire in circuit I just do like you did and replace with a known good one now , in the past in a emergency I used the plastic cap of a 2 L carton of milk to cap off waste worked a treat keep one on the van now 😆

    • @Heatking
      @Heatking  2 місяці тому

      What an idea with the milk carton lid! Haha. I recon that’s a permanent fix rather than a temporary one 😂😂 yeh thermistors are a pain to diagnose correctly!

  • @bluedwarf8858
    @bluedwarf8858 2 місяці тому +1

    Under the sink i came across the same issue, i used a 2p coin and plumbers mait, it was only supposed to be a temporary fix but 2 years later its still there

    • @Heatking
      @Heatking  2 місяці тому

      Another great idea! Thank you mate.

  • @johnrowland6214
    @johnrowland6214 2 місяці тому +1

    feed first as it sucks in air if you pull the vent off first

    • @Heatking
      @Heatking  2 місяці тому

      Cheers John! ♥️

  • @Snaggleplops
    @Snaggleplops 2 місяці тому +2

    Had one exactly the same last month resistance seemed ok, even had it in a cup of hot water and watched it respond, threw a new one on just to see and it was absolutely fine 🤷‍♂️

    • @Heatking
      @Heatking  2 місяці тому

      It’s annoying when things like this happen though, has you doubting doesn’t it 😅

    • @paulsmith2931
      @paulsmith2931 2 місяці тому +1

      Had a hot water thermistor do the same on a Worcester a couple of weeks back, run tap, boiler was over heating getting up to 85 degrees really fast and cutting out, water was running Luke warm, thought it was the plate changed that, same problem, checked the thermistor had 12oo ohms -2o degrees, changed it anyway and the boiler was fine, run the old one under the hot tap and you could see the resistance go up with the heat. Baffling.

    • @Heatking
      @Heatking  2 місяці тому

      @@paulsmith2931 this is when I hate repairs 😂😂

  • @pb9926
    @pb9926 2 місяці тому +1

    Great video mate. I always pull the lower bung out first as you always want it pulling water in first and not too much air.👍😎

    • @Heatking
      @Heatking  2 місяці тому +1

      Cheers Pb! I’ll do that in future then! Thanks for the advice mate!

  • @douglaughton7626
    @douglaughton7626 2 місяці тому +1

    Definitely fit the new strainer waste

  • @alanjones1301
    @alanjones1301 2 місяці тому +1

    never heard that called a gravity system Dan is that a Northern thing haha? we call it an open system down South 🤣 🤣 great video btw

    • @Heatking
      @Heatking  2 місяці тому

      Haha cheers Alan, erm… it possibly could be a Northern thing, I’m not actually sure! But yes you’re right it is an open vent system, haha. Cheers

  • @neilbeckett2325
    @neilbeckett2325 2 місяці тому +1

    Best way ignoring bellends. That’s what they hate.

  • @user-li8gr8ur8l
    @user-li8gr8ur8l 2 місяці тому +1

    Top content Dan. Thanks for that. ❤

    • @Heatking
      @Heatking  2 місяці тому +1

      Thank you very much 🙏🏽

  • @andrewoleary9704
    @andrewoleary9704 2 місяці тому

    Used to always put the cap internal. Have been doing external last few years. Does make sense

  • @killercabbage1276
    @killercabbage1276 2 місяці тому +1

    gas meter disc usually fits and works... for a while 😂

    • @Heatking
      @Heatking  2 місяці тому +2

      Haha what a tip!

  • @GoingDownOnJill
    @GoingDownOnJill 2 місяці тому +1

    Plumbers Mait as a Cap 🙈😂

    • @Heatking
      @Heatking  2 місяці тому

      Good shout 😂😂😂

  • @paulj9022
    @paulj9022 2 місяці тому +1

    ❤ 😊

  • @alimack5489
    @alimack5489 2 місяці тому

    Top video mate, although that duotec it’s the Pcb the low voltage side is likely on the way out it’ll come back in at some point. Well hopefully not 🤞 so you were right

    • @Heatking
      @Heatking  2 місяці тому +1

      If it does mate! At least I now know what it will be so thank you! 🙏🏽

  • @charliewillis8527
    @charliewillis8527 2 місяці тому +1

    Sometimes it's quicker just to try bits you need a stock of parts if your doing boiler repairs

    • @Heatking
      @Heatking  2 місяці тому

      Yeh that is true, a stock of boiler parts is ££££, rather than a stock of plumbing parts at £ 😂

    • @charliewillis8527
      @charliewillis8527 2 місяці тому +1

      @@Heatking yes just stick to parts on the most common boiler you work on which I would say is the baxi range and the ideal I mainly work on the Worcester range so have invested in a range of parts fan gas valve stats etc electrodes I give the boilers a full strip down every 4 years which makes a bit more work

    • @charliewillis8527
      @charliewillis8527 2 місяці тому +1

      @@Heatking that job the other day with the nest was the motorised valve it wasn't powering the orange when it opened what's the chances of that lol

    • @Heatking
      @Heatking  2 місяці тому

      @@charliewillis8527 that’s bloody unlucky mate!

    • @charliewillis8527
      @charliewillis8527 2 місяці тому +1

      @@Heatking yes tipical I tested it with both but I didn't count for that lol

  • @Purebeltersteve
    @Purebeltersteve 2 місяці тому +1

    Mate you seriously need to buy a knipex dp50 for waste pipes, best tool i ever bought, cuts and chamfers at the same time

    • @Heatking
      @Heatking  2 місяці тому

      I’ve seen them but never used one, they are decent buy then mate?

    • @Purebeltersteve
      @Purebeltersteve 2 місяці тому +1

      @@Heatking yes mate, absolute game changer is your forever doing inch and quarter and inch and half. Even does 2 inch aswell, couple of rotations and its done

    • @Heatking
      @Heatking  2 місяці тому +1

      @@Purebeltersteve I’m off to look! I’ll blame you when the mrs complains haha.

  • @Chickenboots1
    @Chickenboots1 2 місяці тому

    The NTC commonly runs out of range at the low end (or high temp, as temp increases resistance decreases) when removing and testing at room temperature they usually show up as in range. It’s hard to ever see them out of range under testing conditions. Our job would be easier if they just showed OL when knackered wouldn’t it 😂

    • @Heatking
      @Heatking  2 місяці тому

      Haha yeh it would mate! Thank you for the knowledge though! That’s massively appreciated!

    • @Chickenboots1
      @Chickenboots1 2 місяці тому +1

      25yr a technician now, nothing surprises me, some days I wish I just worked in Greggs 🤣🤣

    • @Heatking
      @Heatking  2 місяці тому

      @@Chickenboots1 haha I bet you’ve forgot more than I know though! 😂

  • @richard.cook.
    @richard.cook. 2 місяці тому

    That happened to me we moved house I do most of the DIY myself I plumber the washing machine in wouldn't drain called my mate who's a plumber straight away he said about the bung lol

    • @Heatking
      @Heatking  2 місяці тому

      Haha, it’s easily done mate! But you’ll know from now on! 👍🏼

  • @wolvolad25
    @wolvolad25 2 місяці тому +1

    Can you use inhibitors in gravity systems Dan, is the tank filling the rads confused how they work

    • @Heatking
      @Heatking  2 місяці тому +1

      Yeh you can use inhibitors, yes the tank fills the system, I’ll try an explain it one video one day haha

  • @macpatel7810
    @macpatel7810 2 місяці тому +2

    Defo new waste. The way you did it. 30-40 mins of your time has got to be worth more than a £6 waste. Or cut a marigold dishwasher glove and use it as a sealing washer around that black plastic ring and tighten the nut

    • @Heatking
      @Heatking  2 місяці тому

      Cheers Mate, and good shout on the marigolds 😂

  • @jezlucas3878
    @jezlucas3878 2 місяці тому

    I hardly ever get boiler repairs now everything under warranty

    • @Heatking
      @Heatking  2 місяці тому

      Yeh that is true mate. The longer warranty’s are definitely effecting us now.

  • @SuperWayneyb
    @SuperWayneyb 2 місяці тому

    🤘😎🤘

    • @Heatking
      @Heatking  2 місяці тому +1

      Cheers Wayne 🙏🏽

  • @Snaggleplops
    @Snaggleplops 2 місяці тому

    Had one exactly the same last month resistance seemed ok, even had it in a cup of hot water and watched it respond, threw a new one on just to see and it was absolutely fine 🤷‍♂️