Inovance VFD Programming and Control Terminal Wiring| In Hindi| Inovance Drive Parameter setting|
Вставка
- Опубліковано 15 вер 2024
- Inovance Drive Programming and Control Terminal Wiring. Is video me Inovance ki vfd me parameter kese dalte he and pushbuttons, switches , potentiometer ka connection kese karte he vo bataya he.
If you have any question please comment below. I am Happy to reply your Questions. Thanx freinds For Watching this video. Please Like, Share and Subscribe to my Chanel,
Mail: niceelectronics8831@gmail.com
#Inovance #InovanceDriveParameter #InovanceVfdWiring #InovanceAcDrive #Inovanceterminalwiring #InovanceVfd #inovanceHindi
Very nice 👍
Thank you sir ji.
Thnx sir
Sir thoda nahi
Bahut jyada help full tha
Mere liye ..
Thank you very much..
Sir drive ko only stop aur start karna ho to para meter me tarminal kaise set kare ..
Plzzz sir jaldi reply kare
Plzzzzz
Thanks..
Sir rexroth VFC 3610 parameter ka setting videos chahia
Thanks bhai
Sir inch bale bolt ki short video banaio
Sirr err11 solution btavo pless
How to remove remote mode to run mode?
Sir, I have set parameters for the drive as Two wire mode 1 and F0-02-1, F0-03-2, F4-11-0, F4-00-4. I want to run my motor only when the switch is On and should stop when the switch is open (like inching), but my frequency is not increasing above 2.00(that is what I see on display of the same VFD), I am unable to increase my speed beyond that from my Potential connected externally. Kindly reply and provide me some solution. Thank you.
Factor reset kase kare
Yaskawa F7 drive me sabhi program ka video bnaye
Great 👍 video sir.....
Sir.. One of my same drive moving in only one direction .. Kindly help in that .
Mere pas md330nt tension control drive he is me deceleration ka parameters bata sakte ho ap?
Mere pas manual he par wo complete manual nhi he.
Sorry tension control drive have no acceleration and deceleration time they work on the basic of tension.
Change the values of B0-24 and check
Sir inovence deive me error 10 aave che to how to problem solution??
Vfd overload
Electronic AC drive ka programming video hona mere ko
Sir ia ka lock kolna bata de
Second speed mate sir?
Sir, vfd training ki Best institute ka name bataye
No vfd training institute are available. You can learn by doing job at a company related to vfd.
Inovance MD280NT3.7GB/5.5PB
factory locked parameter how to unlock??
Kis make ki ac drive lu
Vo to apki application and budget pe depend karta he vese to Yaskawa, ABB, Schneider make ki vfd achi ati he..
Thank you sir 🌺
User mistake alram hai kya kr skte hai sir
Konsi vfd and alarm code konsa he..
Ok sir aap guro but
Apna number kaha milega
showing Error 2, how to check & solution of the problem?
Inovance MD320
Erorr 10
Drive Overload , do Auto Tune and verify how much Ampere drawn from VFD
Inovance md320 error 09....???
What's error number 23 in this
English please
Errr 13 aaa raha hai
Aapka email id mil sakta hai
niceelectronics8831@gmail.com
Very nice sir
Thank you sir.