Vedio bht acha ta or samj b gya .sit me sigrate pectory me kam krta ho os me hmary pas Gs k inverter lagy he agr es model Gs 504-055 ka mujy ak dpa samja dy to bare bare mehrabani hoge .
Sir apne Programming related bohot vidio dale hai mene sare dekh liye hai 👍 sub ache hai ab reparing ke bhi vidio upload karia plas programing se bohot sari error kese solve karte hai aska bhi vidio dalo👍
Can we run Fuji vfd on 2 phase incoming supply? Considering heat and degradation in am planning to purchase 20 hp vfd for 10 hp borewell pump in my farm. Some vfd maker like delta has phase loss alarm.
Thanx Jitendra Navanale For your Comment. Please set Maximum Speed in parameter No 1) F15 Frequency Limiter (High) 2) F03 Maximum Frequency Parntu isme 5HZ se jyada frequency mat badhana kyoki ise apki motor ki vibration bi badhegi or mechanical damage ho sakata he. Thanx.
I'm also facing issue Fuji mini vfd. We are using in overhead crane. When we push the button North/South motor not rotate. Also i check the remote button function its normal..what is the problem can you share me hints..
Thanx Karuna sagar For your Comment. Sorry vfd ka output pure sinusoidal nahi hota but vo PWM Type hota he so ap vfd ka output motor ke alava koi other applications ke liye nahi kar sakte. ua-cam.com/video/nMyZnIrA_1M/v-deo.html Ye video apke liye vfd ko smajne ke liye kafi helpful hoga. Isme mene apke question ke bare me detail me samjaya he..Thanx
Vfd ka output pure sinusoidal nahi hota but vo PWM Type hota he so ap vfd ka output ka use motor ke alava koi other applications ke liye nahi kar sakte. ua-cam.com/video/nMyZnIrA_1M/v-deo.html Ye video apke liye vfd ko smajne ke liye kafi helpful hoga. Isme mene apke question ke bare me detail me samjaya he..Thanx
I will try to cover most common error occurred mostly in vfd..The following video will help you to solve some error in your vfd ua-cam.com/video/aa24ru_fLVY/v-deo.html ua-cam.com/video/ezGe-f7JRpQ/v-deo.html
Hi sir when I adjusted my Fuji dry on deceleration time 6 seconds to 2 seconds when I run motor on screen massage Foo2 display...so what should I do Let me know... thanks
End Timer (ET) specifies the waiting time from when the control object stops at E point until the inverter can receive the next positioning control signal. After completion of positioning, when this waiting time has elapsed or when 0.5 second has elapsedif ET < 0.5 second, the inverter issues the "Positioning completed" signal "PSET" or "Stop point alarm" signal "OT".
Kya apki vfd postion control ke liye use ki he..? Agar position control ke liye use ki he to kya apki vfd motor ki position ko sahi tarah se set karti he.?
Thanx Balwant Meena for your comment. Run command ke liye jo wiring kiya he usko check karo . And phir bhi problem a raha he to vfd ko reset kar ke phir se parameter set karo .. Thanx
OH2 is due to a digital input is programmed for THR(9) and not connected. check E01, E02, E03,E04,E05 parameter in any parameter set value is 9 then change this setting.
Nice explanation sir, but here i Request you sir, bahot hi fast mode me aap switching kar rahe ho or sath me fast fast samja rahe ho... plz overcome your teaching speed.... jo banda basic se start kar raha he vfd ki parameters padhai uske liye aapka video bahut hi fayde mand he lekin aapki switching itni fast ho rahi he ki aapke wording ke sath isse samjna confusion ho raha he..... thank you
Allen Bradley PowerFlex 4 & 40 VFD Programming and Control Terminal Wiring ua-cam.com/video/TAzGvYbwRqw/v-deo.html Allen Bradley Powerflex 4M VFD Programming and Control wiring ua-cam.com/video/xjiI_tlRAsU/v-deo.html
Namaste sab mera problem hai frenic eco 45 kw drive..may extranal on off no nc connection diya ta drive on ho raha hai frequency badha nahi gatta nahi and remot may parameters change nahi ho raha hai...frequency 0 00 dika raha hai...what is sollution sir...
I have a motor with brake installed. Brake connection is through 30A-30C connection. From 50hz to 0hz in 5 seconds. After reaching 0hz I want to apply DC braking through drive for 3 second. External brake connected should apply brake after 2 seconds when 0hz reached. Please help
For Dc breaking through drive set Set F20 = Dc Breaking Start Frequency = 0HZ, F22= DC Breaking Time = 3 Seconds, For External break through 30A-30C Connection set E27= Terminal(30A/B/C) Function = 57 Break signal , J71 Brake on frequency = 0HZ, J72 Break on timer = 2 Seconds.
Thanx For your Comment. OV1 ERROR is due to over voltage during acceleration so increase acceleration time and check . OV3 ERROR is due to Over voltage during Running so check 1) any mechanical jam occurs in motor side or if Motor side there is no mechanical jam then 2) you need to check the dc voltage during motor running between POSITIVE and NEGATIVE terminal If they are more then 700 then 3) you need to use breaking resistor according to your HP of Drive.
@@niceelectronics9505 sir fuji electric frenic mini Solar pannel 320*4 hai 110v 0.75hp pump hai Yeh mere gaon me laga hai! Iska settings and wiring k bare batate toh thik hota
Aone mera problem solve kr diya sir
Thanks Niraj Raja. If you have any other vfd related problems then please comment below..
7369963119coll me
Please mention your problem here..
@@niceelectronics9505 sir call ni lag rha hai
Hamari firm hai golden food equipment se
Sir app ke smjhane ka tarika very good👍
Plzz keep making such videos, because I am working in Elevator field
Sir ye video se bahut kuch samaj me aagaya
Lekn meri samj ma nai AA raha
I have doubts in rpm
Kiya rpm ko calculate krna padega
Like you did
Frequency 60+30 =90*2= *180* ??
Your way of understanding is very good.
Vedio bht acha ta or samj b gya .sit me sigrate pectory me kam krta ho os me hmary pas Gs k inverter lagy he agr es model Gs 504-055 ka mujy ak dpa samja dy to bare bare mehrabani hoge .
Please send Manual.
Kiya AC se chala sakte hai sir ji
Sir. Kia. Bat. Hai. Sir. App. Bahut. Good. Bataye. Sir. Bahut. Sunder. Sir. Draive560abb. Pe. Ese. Hi. Video. Banaiye. Sir. Dhanybad. Sir. Veri. Nise. Video. Sir
Sir apne Programming related bohot vidio dale hai mene sare dekh liye hai 👍 sub ache hai ab reparing ke bhi vidio upload karia plas programing se bohot sari error kese solve karte hai aska bhi vidio dalo👍
Can we run Fuji vfd on 2 phase incoming supply?
Considering heat and degradation in am planning to purchase 20 hp vfd for 10 hp borewell pump in my farm. Some vfd maker like delta has phase loss alarm.
Maine solar connection diya hai Fuji Mini ko 5hp ka motor hain borewell me uska Speed kaise badana pls bataye ya motor hi jada HP ka lena padega?🙏
Thanx Jitendra Navanale For your Comment. Please set Maximum Speed in parameter No
1) F15 Frequency Limiter (High)
2) F03 Maximum Frequency
Parntu isme 5HZ se jyada frequency mat badhana kyoki ise apki motor ki vibration bi badhegi or mechanical damage ho sakata he.
Thanx.
Bhai konsa bhi vfd ka sem hota hai kya pyara meter
Sir. Bahut. Sunder. Video. Sir. Kia. Bideo. Banaye. Hai. Bahut. Bahut. Dhanybad
Bro PG card vali drive lagti he na With encoder vo bhi batado please 😮 thank for information 😅
Sir mere paas fuji frenic mini drive he. 5 HP. 3fase submarsible pump he. Iska ampire kitna hoga, motar selection me kitna no (0-1-2-4) select karna hai, please bataye.
Video me mention kiya he ...
Nic video bro...
Kindly make a video on installation of breaking resistor
Please visit this two video on breaking resistor
ua-cam.com/video/DQc1VraBoHM/v-deo.html
ua-cam.com/video/ePw_rGxgwIw/v-deo.html
Thanx
Please sir,aapka video bahot achaa laga
2 wire logic me jogging hota hai?
Yes
Broo is m phase filler ka option kic parameters par atta hy. Can you tell me
Good morning, what kind of potentiometer is necessary?
Sir hum drive me supply dene ke baad kya 11 aur 13 ke beech voltage 10 v ayega
I'm also facing issue Fuji mini vfd. We are using in overhead crane. When we push the button North/South motor not rotate. Also i check the remote button function its normal..what is the problem can you share me hints..
🙏 Namaskar sir mere pass 5 HP ka solar pump me, fuji frenic mini ka VFD laga he, isse 3 HP ka motar b chal sakta hai.
Hi. Can you tell me if it's possible in Fuji VFD to add an AC/DC changeover switch?
sir mere 5hp ki motar he or wo pani kam de rhi he to uski controlar me kya satting change krni padegi to pani ka discharge jada ho ske
Very nice and helpful
Sir VFD EL me oc over current ho raha hai iska koi solution hai
ua-cam.com/video/ezGe-f7JRpQ/v-deo.html
Sir run command par zero show karta hai display par Fuji mega too aap koi help kar sakte hai...
Kya Main Yeh driver elevator main use kar sakta hun relay wala panel Hai Mere pas
Ha ap kar sakte he..
How to connect PC to inverter communication cable and make programming also please
Sir isme se ac nikal sakte hain kya direct use karne k liye
Thanx Karuna sagar For your Comment. Sorry vfd ka output pure sinusoidal nahi hota but vo PWM Type hota he so ap vfd ka output motor ke alava koi other applications ke liye nahi kar sakte. ua-cam.com/video/nMyZnIrA_1M/v-deo.html
Ye video apke liye vfd ko smajne ke liye kafi helpful hoga. Isme mene apke question ke bare me detail me samjaya he..Thanx
Sir esme singal phase use karke light chala sakte hai kya ...
@@gandhivideoandphotography1769 nehi karsakte sayad !
Yes Karuna sagar you are right..
Vfd ka output pure sinusoidal nahi hota but vo PWM Type hota he so ap vfd ka output ka use motor ke alava koi other applications ke liye nahi kar sakte. ua-cam.com/video/nMyZnIrA_1M/v-deo.html
Ye video apke liye vfd ko smajne ke liye kafi helpful hoga. Isme mene apke question ke bare me detail me samjaya he..Thanx
Sir,
How can I select Motor Rated RPM/Number of Poles?
noob question, is this possible to do auto stop if hit certain amount of ampere or anything?, mine has broken because it's doesn't stop when stuck :(
Kaha he appke shop
sir ge mere pas FVRO 4E9S-2 inverter hai out put voltage kam hai compare to Input voltage kya problem hai plz tell me
Good Explained. Use full video. Need video feji drive alarms. Explain. Thanks
I will try to cover most common error occurred mostly in vfd..The following video will help you to solve some error in your vfd
ua-cam.com/video/aa24ru_fLVY/v-deo.html
ua-cam.com/video/ezGe-f7JRpQ/v-deo.html
@@niceelectronics9505 thanks bro. Thanks for Reply...
@@niceelectronics9505 bro fuji drive.for use sump pump. Alaram came 0U2 .i think over voltage. I am not clear.please tell me correct resan.
Please watch this video may solve your problem ua-cam.com/video/aa24ru_fLVY/v-deo.html
@@niceelectronics9505 thanks bro. I watch okay.
Nice post sir 🙏 thank you
Sir 300 va m 110 ka break sply hota hai. Break sply 190 Chai a to contactor se ho skta h? Plss help
Also specify parameters for running PMSM motor with drive?
Sir modbus RTU communication k liye kya command setting krna padta hain?
Hi sir when I adjusted my Fuji dry on deceleration time 6 seconds to 2 seconds when I run motor on screen massage Foo2 display...so what should I do Let me know... thanks
Greetings, sorry in which function can I program the startup time, I want 10 seconds to pass and then start the startup process
Dear sir please the requested my drive fuji mini 5hp error LU please sir q aa raha hai ? Aapka vidio best tha sir ❤️
Lu ka meaning lower voltage he please check input supply and input mcb.
Que parámetros hay que poner para que arranque automático
Superb job sir
Moter discharge Kam de rahi he
Problam slove kre sir
PLC panel se auto may VFD kam
Nahe kar rahe he plz sir
Sir frenic ace h terminal se rev chal rhi h fwd nhi chal rhi koi parameter ho to btaiye
Sir ye khridni h kha milegi
Sir drive main ot foult Kya h?
End Timer (ET) specifies the waiting time from when the control object stops at E point until the inverter can receive the next positioning control signal. After completion of positioning, when this waiting time has elapsed or when 0.5 second has elapsedif ET < 0.5 second, the inverter issues the "Positioning completed" signal "PSET" or "Stop point alarm" signal "OT".
I need solution sir.
Kya apki vfd postion control ke liye use ki he..? Agar position control ke liye use ki he to kya apki vfd motor ki position ko sahi tarah se set karti he.?
Fuji frenic ace vfd me
RPM kis parameter se set hote hai...
very well understand sir
thanks a lot
Sir temperate high ka perameter kon sa hai vfd card 68c' tak ja raha trip ni ho rahi
Apki vfd ka cooling fan check karo. Sorry Temperature ke liye koi parameter Nahi ata.
Fuji Ace me kya drive runing slow / fast krna h par nhi ho raha h band karke krna par raha
Speed Slow fast kaha se karte ho?
my frenic mini is not resetting to pragraming mode even by ptessing up-down and stop buton, how can i get factory setting.
Please try using another keypad.
Sir ji ..Nx2000+ VFD .. (LNT) ki program settings nhi ho rha
Hi sir my drive has no output though ,run light is on ...
Fuji mini isolation kiya tha usme moter 20 minit hi chalti he bad me band ho jati he uska Karan Kya he
Thanx Balwant Meena for your comment. Run command ke liye jo wiring kiya he usko check karo . And phir bhi problem a raha he to vfd ko reset kar ke phir se parameter set karo .. Thanx
External potential kitne k ka lgy ga
Drive reset karne ke bad.....ac output 26v nhi dc 300v mil raha hai uvw Mai....to kya problem ho sakti hai sir .
Sir isme OH2 disply batara kia karre sir?
OH2 is due to a digital input is programmed for THR(9) and not connected. check E01, E02, E03,E04,E05 parameter in any parameter set value is 9 then change this setting.
Nice explanation sir, but here i Request you sir, bahot hi fast mode me aap switching kar rahe ho or sath me fast fast samja rahe ho... plz overcome your teaching speed.... jo banda basic se start kar raha he vfd ki parameters padhai uske liye aapka video bahut hi fayde mand he lekin aapki switching itni fast ho rahi he ki aapke wording ke sath isse samjna confusion ho raha he..... thank you
Thanx Mayur gohel for your kind response I will try to improve it in upcoming videos..
Plz help I can’t change f00
How to unlock??
Sir isme agar U01 error show kar raha ho to kya kare ....is case me reset kaise kare plz help
very good explained
Thanks sir for kind information sir vo parameters k bare ma btao jisme push ko on karne pa speed up or dawn hota hai
F01 = Frequency Command =7
E01 = X1 Terminal = 17 Speed Up
E02 = X2 Terminal = 18 Speed dowm
Thanks you sir
Sir is vfd me solar panels ka wire kaha lagega please help me thanks
6panels 24v
+-
Allen bradley ki drive ki wirings bataye sir. Auto and manual me chalana
Allen Bradley PowerFlex 4 & 40 VFD Programming and Control Terminal Wiring
ua-cam.com/video/TAzGvYbwRqw/v-deo.html
Allen Bradley Powerflex 4M VFD Programming and Control wiring
ua-cam.com/video/xjiI_tlRAsU/v-deo.html
Hello sir , drive me LU ka aalarm aakr trip ho jata h please sir
Fuji me ECF foult areye kay problem plz tell me
In Fuji drive I will connect 1.5 kw motor and set all parameters then start but it will show OL1 in load condition when frequency will lower than 10hz
Please check Voltage, frequency and Current settings in VFD they are same as the name plate on motor...
Frenic 5000G11 inverter hai os k pani ka preshar barhana chahte hn 7.5hp 5.5kw motor hai . plz setting bta.den
Frenic mini me three treminal hai no1-30B 30C me jo wire conect kis kam ke liye aur 11/12no FWD me aur plc me wire conect enka bhi kam bataye pls.
Please make a video on fuji FVR Micro model
Sir fuji mini drive problem... Drive is running but moter is no run CM, fwrd wairing connection sart no working moter please help me
मोटर चैक करवा लो
Sir mera ek fuji ka yahi mashine hai jo hum set nhi kar pa rahe hai plz aap mujhe help kre
Sir,
Ac tech ka video banaye
Sir Ji oc3 and olu aa rha he kya solutions he sir ji
Fuji electric VFD per ek video banaye aage ki programing please sir
What is the P04
Namaste sab mera problem hai frenic eco 45 kw drive..may extranal on off no nc connection diya ta drive on ho raha hai frequency badha nahi gatta nahi and remot may parameters change nahi ho raha hai...frequency 0 00 dika raha hai...what is sollution sir...
Thank you bro.
Bhai VFD Hame manually chalana he to kya karu
I have a motor with brake installed. Brake connection is through 30A-30C connection. From 50hz to 0hz in 5 seconds. After reaching 0hz I want to apply DC braking through drive for 3 second. External brake connected should apply brake after 2 seconds when 0hz reached.
Please help
Please give reply to this also
For Dc breaking through drive set Set F20 = Dc Breaking Start Frequency = 0HZ, F22= DC Breaking Time = 3 Seconds, For External break through 30A-30C Connection set E27= Terminal(30A/B/C) Function = 57 Break signal , J71 Brake on frequency = 0HZ, J72 Break on timer = 2 Seconds.
@@niceelectronics9505 Thanks for solution. I will try and update the outcome.
Super sir
Nice video Sir.
Fauji fvr c11 ki programming btana. Thanks
Similar to mention in this video..
Sir fuji drive with all parameters detail video bnado please🙏
Please solve my problem sir my starter show the error ou3 and ou1
Thanx For your Comment. OV1 ERROR is due to over voltage during acceleration so increase acceleration time and check . OV3 ERROR is due to Over voltage during Running so check 1) any mechanical jam occurs in motor side or if Motor side there is no mechanical jam then 2) you need to check the dc voltage during motor running between POSITIVE and NEGATIVE terminal If they are more then 700 then 3) you need to use breaking resistor according to your HP of Drive.
@@niceelectronics9505 thank 🙏💕🙏💕🙏💕🙏💕
टॉर्क मोड व फ्रिक्वेन्सी मोड कोणते पेरिमीटर आहे.
Out put limit stop . What's the problem
30 kw induction motor ke liye parameter set karna Bata dijiye
Please watch video care fully only motor parameter will change and other remain same for all kw vfd.
1.5 kw 2 hp 160 volt kab pump is pump ko chalane ke liye kaun sa parameter set karna padega sar
क्या हम इस ड्राइव से घर का लोड चला सकते हैं
No
Sir 1hp ka pump lagala hai solar pannel se wiring kwi se karen
Thanx Karuna sagar Patel for your comment..solar vfd ka model konsa he?
@@niceelectronics9505 sir fuji electric frenic mini
Solar pannel 320*4 hai
110v 0.75hp pump hai
Yeh mere gaon me laga hai!
Iska settings and wiring k bare batate toh thik hota
Please refer this manual for complete installation..www.fujielectric-europe.com/gallery/download/download_508/jde085_00031a_ace_solar_pumping_im.pdf
Can you please Translate this to English? Some parts i didn't understand.......good job
Sir ji.
Stoping & start time jhatka ata he kon se parameter check kare.
Acceleration and deceleration time mentioned in video.
Please help me .
After the factory reset for frenic-ace. when I push "RUN" the inverter doesn't run and the message "--En " in the keypad.
Thanx guidir fadili for your comment. I shown in manual there is no information available --En in VFD manual please check it again and reply.. Thanx
Fuji pxf5 program run Kai kare ge
Sir i have try to to speed increase but not increase .i have allready 3&15 parameter set 75 but same speed running not speed increase
Try it after restore all parameter to factory setting. Only If you are confident about program your vfd as per your application.
Sir hamare drive ol1 ki proble aa rahe hai
Kaise solve ho gi
Nice bhai
Repair karwana hai fentic mini
Mitsubishi AC drive ka parameters all with communication parameters please one video share.