Renogy Rover Li 40 amp MPPT Solar Charge Controller Overview

Поділитися
Вставка
  • Опубліковано 25 чер 2022
  • Renogy Rover Li 40 amp MPPT Solar Charge Controller Overview - A first look at the Renogy Rover Li 40 amp MPPT Solar Charge Controller. I will be using this solar charge controller to power the Off Grid Workshop project.
    Renogy Affiliate Links:
    Use code DIYHOME to save 8% here:
    renogy.sjv.io/QOdxrP
    New 12V 100Ah Pro Smart Lithium Iron Phosphate Battery
    renogy.sjv.io/eK0KaZ
    New 400 Watt 12 Volt Solar Premium Kit
    renogy.sjv.io/9W39V5
    Rover Li 40 Amp MPPT Solar Charge Controller
    renogy.sjv.io/kjXeoM
    100 Watt 12 Volt Monocrystalline Solar Panel (Compact Design)
    renogy.sjv.io/e4G9Ag
    2000W 12V Pure Sine Wave Inverter
    renogy.sjv.io/kjXk4L
    3000W 12V Pure Sine Wave Inverter
    renogy.sjv.io/P0ZX66
    REGO off-grid power system
    renogy.sjv.io/xkEEgk
    REGO 12V 400Ah Lithium Iron Phosphate Battery w/ Renogy ONE
    renogy.sjv.io/5gaavn
    REGO 12V 3000W Pure Sine Wave Inverter Charger w/ LCD Display
    renogy.sjv.io/eKvvLg
    REGO 12V 60A MPPT Solar Charge Controller
    renogy.sjv.io/AW00vR
    REGO 12V 60A DC-DC Battery Charger
    renogy.sjv.io/JzbbMQ
    REGO 4 Port 400A System Combiner Box
    renogy.sjv.io/oqRRkg
    The Renogy Home app admin password is: 135790123 (Use this password to set up the admin security so you can change device settings in the Renogy Home app. Once set up you can change the admin password to what ever you prefer.
    DON'T FORGET TO LIKE COMMENT AND SUBSCRIBE
    / @diyhomesteadprojectsd...
    Top videos you need to see:
    NEW Renogy REGO Off Grid Solar Power System Overview - Massive Battery Storage Capability!
    • NEW Renogy REGO Off Gr...
    Car won't start in COLD WEATHER? Renogy Solar Battery Trickle Charger
    • Car won't start in COL...
    DIY LiFePO4 Battery Build - Sun Fun Kits
    • DIY LiFePO4 Battery Bu...
    If you would like to help support my channel and use the WannaBFree Amazon affiliate link, I thank you in advance for your support. As an Amazon Associate I may earn from qualifying purchases and no extra cost to you.
    WannaBFree Amazon affiliate link
    www.amazon.com/shop/wannabfree
    Link to my other channel with lots of camper van and travel videos
    ua-cam.com/users/WannaBFree?...
  • Навчання та стиль

КОМЕНТАРІ • 114

  • @DIYHomesteadProjectsDIYHP10
    @DIYHomesteadProjectsDIYHP10  2 роки тому +3

    See the first video in the Off Grid Workshop Build
    ua-cam.com/video/gwSetK7_-f4/v-deo.html

  • @CaliBeats
    @CaliBeats 2 роки тому +3

    Thankyou! i just bought one and im hypeddd!!!

  • @jeffrichmond-bate2573
    @jeffrichmond-bate2573 Рік тому +1

    thank you going to set mine up next week

  • @mmunoz5875
    @mmunoz5875 9 місяців тому +1

    Well explained and thank you!

  • @ejdd3442
    @ejdd3442 10 місяців тому +3

    Great Video, I purchased this controller (60 AMP essentially the same) for my boat and am OK with it. I use it to keep 400 AH lithium batteries charged, monitor with the BT2. My energy consumers use relatively low amperage except for the 12 volt fridge and that is somewhat low. My only issue is the Load terminals, they do not output voltage they are in the off mode all the time. It seems like the design is to output voltage when the panels are not powered (night), this makes no sense to me, unless you are simply using it for a timer after the panels stop producing. I thought the purpose of load is to use surplus energy when the batteries are topped off, that would be a great idea since the solar panels would not have any use for the solar energy after the batteries are at 100%+.

  • @3phasetinkerer
    @3phasetinkerer Рік тому +1

    Thank you for this video. I'm a newbie with these things and discovering free energy. Very difficult to find a good controller with good price. I think I'll go with this.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      You're welcome Serdar. I've been using Renogy solar products for several years now and I've been happy with their products. I wish you the best with your solar ventures and thanks for stopping by.

  • @munney-b650
    @munney-b650 26 днів тому +1

    Go to where it has the Celsius setting and hold down the right arrow until it switches to Fahrenheit. Didn't go through all the comments so if someone already put this out then awesome

    • @andrewt8116
      @andrewt8116 12 днів тому

      Fake news, I tried and it didn't work

  • @nofantasyman
    @nofantasyman Рік тому

    good. i like it in parts too.

  • @joelywii
    @joelywii 11 місяців тому +1

    I have one on my 100 watt solar setup and its keeping my 100ah lithium battery constantly topped up. No worries so far.

  • @Supanova70
    @Supanova70 3 місяці тому

    If you have 2 seperate battery banks with isotlators does this charge work with it and split the load of the panels?

  • @732Runner
    @732Runner 9 місяців тому

    Just got this one for a single 100ah fed by a 100w panel I was thinking it might be to much.. seems like it’s gonna be ok!

  • @christineminkyungjo7648
    @christineminkyungjo7648 9 місяців тому

    Thank you. Rego 12v 400ah is same?

  • @MrKevin010
    @MrKevin010 Рік тому

    Can get that history data from the main screen? Thanks.

  • @jpmo82
    @jpmo82 6 місяців тому

    Hi friends, my mppt rover 40a is not giving accurate battery percentage, it is propperly configured in 12v and lifepo4 battery, battery is new and mppt too, any other setting to make or help? thanks, regards.

  • @alutious
    @alutious Рік тому +1

    Hi I looked at the manual on the rover 40, regarding the load terminals. I don't get it. What is this intended to power while there is no sun? The only thing I can think of powering (in an rv), is in the battery electrical rover 40 compartment, a fan. However it would be hotter when the sun is out and the batteries are charging, so i would think i would want the load to power this when the charging is on. But the load controls are only all on or off, or load on when not charging. What am i missing? thx.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +1

      My understanding is the load is used to power low amp draw items. It can be programed several different ways. Dusk to dawn for instance can be used for a porch light or night light. I've seen people use it for a heat lamp in a chicken coop. Maybe you would use it for an air circulating fan during specific times using the timer feature. If you are in an RV and maybe going to be coming back after the sun goes down you could have a night light or porch lights on using the load feature on the charge controller. It is somewhat confusing and does make a person wonder what the real intent is with this feature.

  • @Twindadx2_
    @Twindadx2_ Рік тому

    I am having issues trying to figure out the right setting to turn the load off when my battery drops too low. Right now the load setting is at 15 which is the on/off mode. I am using the 2x 100 watt panels with the 30 amp charge controller.
    I am using this setup to run my surflo vacuum pump for maple sap. The solar panel keeps the battery topped up during the day but at night when the panel is not supplying power the battery will drain completely and throw the E03 error code. Which setting do I use so that the solar controller turns the pump (load)off when the battery volts/amps gets too low?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      I don't know, I have mine set on 15 and it's always off. I am not using the load circuit on mine. I think the manual tells what all the different settings are used for in the load settings.

  • @reggaeone
    @reggaeone Рік тому +2

    well done overview...thanks

  • @donaldd.293
    @donaldd.293 6 місяців тому

    I set mind up similar to you but it always goes back to factory settings. I’m stumped

  • @william38022
    @william38022 Рік тому +1

    I’ve had good luck with the 12 V 100 W panels they sell however I got burned big time on a commander charge controller Renorgy solar sold me it quit working shortly after warranty and they wouldn’t do anything at all about it they wouldn’t even offer me a discount on a new one nothing. I thought about these rovers however I’m not sure. has anybody had any luck with their sealed lead acid/AGM batteries they sell ? I looked at their 200 amp hours batteries however I’m afraid I’ll get them and they’ll stop working.

  • @jpmo82
    @jpmo82 7 місяців тому +1

    Hi, great video, i understand that rover 40a have a maximum 100v pv input, but how many amps in the input? Thanks

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  7 місяців тому +1

      The manual states max input is: (Max. PV Input Power: 12V/520W, 24V/1040W) So either of these input voltages would equate to 43.33 amps input. (watts divided by voltage equals amps)

  • @charlie1234567ize
    @charlie1234567ize Рік тому +1

    I have one renogy battery 12v, would this be ok to charge with one 100 watts and one 200 watts solar panels total 300 watts to charge battery every day ?

  • @christopherowens2635
    @christopherowens2635 3 місяці тому

    If I want to go 48v, do I change any setting on the charge controller?

  • @penncapt
    @penncapt Рік тому

    Will this charge 7S lipo to 29 volts? 28 volts? I am building a power station for camping/ fishing. I want a charger I can put 50 volt solar into, plus 36 volt stepped up from truck alternator, plus 36 volt from a 120 ac power supply. Will this work for all 3 inputs?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      I'm not sure but the specs state a max battery voltage of 32V. You can download a PDF of the instruction manual near the bottom of the product page. I'll leave you a link and maybe you can find more specific information about your application there. I wish you the best with your project.
      Rover Li 40 Amp MPPT Solar Charge Controller
      renogy.sjv.io/kjXeoM

  • @agralt7405
    @agralt7405 Рік тому +1

    If I connect two batteries in parallel and not in series - (2 x 110ah in parallel) and connect these two solar panels 2 x 300W, will it make a difference? can i then use 40A RENOGY or 60A?
    The rule also applies here: 600w : 12v = 50A ?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +1

      Divide the total solar watts by the voltage you are charging at and that will give you the required amperage of the charge controller. This rule will apply no matter how you wire up the batteries. You basically have two choices, two 12v batteries wired in parallel and you're charging at 12v = 47 amp or larger charge controller. Two 12v batteries wired in series and you need to charge at 24v = you could get away with a 30 amp or larger charge controller.

    • @agralt7405
      @agralt7405 Рік тому +1

      @@DIYHomesteadProjectsDIYHP10 I see. Thank you.

  • @jpmo82
    @jpmo82 6 місяців тому

    hi, to main questions, unit have backlight? how reset? thanks.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  6 місяців тому

      I don’t think it has a backlight. I’d have to look at the manual for reset instructions. You can download the manual off the Renogy website if you want to see it.

  • @cdawgRJ
    @cdawgRJ Рік тому +3

    Would this be able to run a small tv on a camper? Let’s say 3 hours max?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +1

      The solar charge controller only charges the battery bank. Your battery bank and inverter will be what runs the TV.

    • @dieseldawg7132
      @dieseldawg7132 5 місяців тому

      @@DIYHomesteadProjectsDIYHP10question I have like 5 amg batteries that I acquired they are 100ah each thinking of putting them in parallel what would be a good one to get 40amp/60/100??? And what would be good panels

  • @iamnegan1515
    @iamnegan1515 Рік тому +2

    Great video. Anyone have a recommendation for inverter for 400 watt solar? I will be using a lithium battery. 👍 Thank you.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      Thank you Iam, I will be using one of the below 3K inverters from Renogy with my 400 watt system for my DIY Off Grid Workshop. We'll see how it performs over time. It sure is a heavy inverter so I'm hoping it is a solid piece of equipment. Good luck with your search! renogy.sjv.io/5bdNB9

    • @crazywayne7051
      @crazywayne7051 Рік тому

      I've been running a small MMP brand 1,000 w all in one inverter from watts 247 it's good for about 145 volts open from the panels the cheaper version is good for 500 watts of solar runs awesome with three 24 volt 200 w Rich solar panels give an open voltage of about 136 volts. The higher voltage means that with less sunlight you still get charging because you exceed the voltage of the battery, my batterys two sok 206 amp hour 12 volt batteries. The same mpp unit can be had with thousand watts of solar capability and 24 volts in other models. Just make sure you use extremely heavy cables to the batteries I'm running number fours and it gives it enough punch I can run a 5000 BTU AC with this thing

  • @daryljackson3704
    @daryljackson3704 Рік тому

    Can this controller have a 24 v battery bank and still power a 12 v inverter ?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      The battery bank is what determines the voltage of the inverter you need to use. If you have a 24V battery bank you need a 24V inverter. If you have a 12V battery bank you need a 12V inverter. This charge controller will charge either a 12V or a 24V battery bank.

  • @dangeroustoman
    @dangeroustoman Рік тому +4

    How many 100watt panels can you hook to that 40amp controller?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +3

      That depends on how you wire the panels. In a 12V configuration you can use 5. If you wire the panels in a 24V configuration you can use 10.

    • @keithshumaker6402
      @keithshumaker6402 Рік тому +1

      Your voltage Makes a different on how many 12 volt has higher amps than 24 volt the higher the voltage the lower the amps

    • @wisalahmad1867
      @wisalahmad1867 Рік тому +1

      You can install total 750watts for 12v and double for 24v to get maximum power

    • @briantelford8532
      @briantelford8532 Рік тому

      I have 10, 100 watt panels on a 12 volt system 5 panels in the array are southeast faceing and 5 are faceing southwest this helps me take advantage of the morning and afternoon sun. Over panneling up to 25 percent is normally never a problem as the controler will dump the excess power as heat. In my particular set up I have never exceeded 35 amps coming in.

  • @agralt7405
    @agralt7405 Рік тому +1

    Tell me, will this 40A regulator be enough for 2x300W solar panels, or will it limit the capabilities of my solar panels? I have 2 110ah AGM 12V batteries. In the technical manual Renogy writes that 40A up to 520 Watt

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      Amps x Volts = Watts so if you divide your total watts by the battery voltage you'll know what size charge controller you'll need.
      (600 watts divided by 12.6 volts = 47.6 amps) You can't safely pull more amps than the charge controller is rated for. Your set up could possibly try to push 47.6 amps into your batteries. You will need to get a 60 amp charge controller for those two 300w solar panels if you are charging 12V batteries. If you use a 40 amp charge controller with 600w of solar you'll probably burn up the charge controller at some point. Hope this helps you out.

    • @agralt7405
      @agralt7405 Рік тому +1

      @@DIYHomesteadProjectsDIYHP10 Thank you very much for your quick reply.
      two batteries connected together (I don't know, parallel or series?) 2 x 110 ah AGM ... two panels at once two batteries ... would it be ok then?
      then by calculation it would give 25.2V, right? Or I would charge 2 batteries separately, each panel to one battery .. if I can, then 40A of the regulator will be enough then?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      If you wire both the batteries and the solar panels in series making a 24 volt system instead of 12 volt system, you would be fine with the 40 amp charge controller. This might create other problems for you if you are running 12 volt items with your system though.

    • @agralt7405
      @agralt7405 Рік тому +1

      @@DIYHomesteadProjectsDIYHP10 Thank you, you helped me a lot today. now i know more. Good luck my friend.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      You're welcome and I wish you the best with your solar projects! Thanks for stopping by!

  • @jah6269
    @jah6269 8 місяців тому +1

    Can I use a 24 volt battery and have a 12 volt output?

  • @chadcurrent1645
    @chadcurrent1645 11 місяців тому

    Im confused, 100A input for 40A charge?

    • @NYCamper62
      @NYCamper62 11 місяців тому +1

      That's 100 dc volts max input.

  • @ronnjerremy5796
    @ronnjerremy5796 29 днів тому +1

    Can you run 24 volts into the controller from the panels and charge 12vovt batteries?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  29 днів тому +1

      Yes, that is how I have mine set up.

    • @ronnjerremy5796
      @ronnjerremy5796 29 днів тому +1

      @@DIYHomesteadProjectsDIYHP10 what are the benefits from this setup?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  28 днів тому +1

      Higher voltage systems allow for lower current, which reduces power losses in the wiring and makes the overall system more efficient. Lower cost for longer wire runs from the solar array to the charge controller. Also you can connect a larger array to the MPPT charge controller without exceeding the controller input limits. Essentially you can do more with a smaller MPPT charge controller and save money over having to purchase a larger amperage charge controller.

    • @ronnjerremy5796
      @ronnjerremy5796 28 днів тому

      @@DIYHomesteadProjectsDIYHP10 thank you great info

  • @SuperDividenz
    @SuperDividenz Рік тому

    does this charge controller require a battery or can i just use the solar power

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      It needs to have a battery connected. Connecting a solar panel to the charge controller without a battery connected will damage the controller according to the instruction manual.

  • @mikedevita5558
    @mikedevita5558 23 дні тому

    I have a BT 1. Where in the app do you find settings? I see nothing.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  23 дні тому

      Open the DC Home app and click on your charge controller. There should be three dots ... in the upper right hand corner. That should give you two choices settings and history. Hope this helps you out.

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  23 дні тому

      Click the three dots ... in the upper right hand corner.

  • @jaaayg2791
    @jaaayg2791 Рік тому +1

    so do i just not need a temp sensor because im using lithium batteries too ?

  • @rudbeckia885
    @rudbeckia885 Рік тому

    My LCD display is cut in half... difficult to impossible to read

  • @pup1008
    @pup1008 Рік тому +1

    I have a slightly older model Rover 20A PG & the operation of it is causing me a near nervous breakdown!
    To explain....
    I'm using the controller with a 100W Renogy panel & an inverter. Everything seems to work like a dream but.... The company has told me that I shouldn't be drawing power from the unit whilst it is being charged from the panel. This effectively stops all use during the day & I'm now wondering what, if any, is a safe amount of charge to be coming down from the panel to allow me to take power from the battery? Should I only use it at night or after 7.... 😵‍💫
    I think the problem(s,) which I've been told could damage my battery, lies in the charging cycles which I now think are not designed/expecting an inverter to be using the system.
    The company have told me to put in a circuit breaker for whenever I want to draw power.
    I'm coming round to thinking that the MPPT is really not designed to work with a setup that uses an inverter?
    Any views/help?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      I have been using two 100W panels and a 12V lead acid battery with a cheap 750W inverter for my camping set up. I have used power from the inverter anytime day or night. I haven't noticed any problems using it that way. I don't understand why they would tell you that.

    • @pup1008
      @pup1008 Рік тому +1

      @@DIYHomesteadProjectsDIYHP10
      Thank you for your reply!
      I'm not sure either. 🤔 I've been happily using the setup in my beach cabin for a couple of years now with no issue that I was aware of.
      The only thing I can think of is when the *Rover* goes through its different charging cycles if pulling a charge, I'm wondering if that can interfere with/damage the battery?
      I know if I have the inverter "On" when the system goes into the "Boost" it can cause the inverter to flash up over voltage warnings.
      I'm so unsure on this now, & whilst waiting for a suitable circuit breaker to arrive, I've taken to clambering up on the roof to disconnect the panel once a maximum charge has been reached!
      I'll try & get back on to the company to get this resolved but my last communique with them really confirmed all this & told me to use a circuit breaker to stop electricity coming from the panel *IF* I was using the battery! 🤔

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +1

      That all makes sense to me. This will be my first MPPT charge controller. My camping set up has a PWM so that may make a difference too. In my off grid workshop set up I will be using DC circuit breakers instead of fuses so I can easily isolate the solar array and battery bank simply by flipping a switch as you mentioned. What battery chemistry are you using? I suppose that may also make a difference due to the charge, boost and float differences for different battery types.

    • @pup1008
      @pup1008 Рік тому +1

      @@DIYHomesteadProjectsDIYHP10
      I've got two 120amp sealed deep cycle leisure batteries.
      I'm now getting the impression the units are (poorly) designed for 12V use primarily....
      Aside from the now warnings of using the kit with an inverter (must have cutout switch) it seems to have another horror in an "Equalisation" phase which occurs every 28th. day of the month. Despite asking Renogy if that is a calendar month or 28 days from when you start using the unit, I'm none the wiser but you are not supposed to use it at all then.
      Funny enough a neighbor who is a Sparks has turned up today so I'm going to run it all by him although most traditional electricians look upon solar as the "dark arts!" 😆
      Thank you again for your interest & help. 👍

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +1

      Sounds like the issue is when the charge controller goes into the different phases of the charge cycle. The voltage from the charge controller to the battery can vary several volts depending on where it is in the charge cycle. I'm guessing this variation of voltage can cause issues with the inverter. It will be interesting to hear what the sparky has to say about it all. 👍

  • @coty397
    @coty397 Рік тому +1

    Can you run these 24v in 12v out?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      Yes, that's how I am running mine. You can go up to 100V in and 12V or 24V out with this charge controller.

  • @tedy2009tedy
    @tedy2009tedy Рік тому +1

    I have the app and on the controller I have managed to change the battery type but not on the app because it's asking the admin permision or something like that ? Does anyone know what to do please?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +1

      Yes if it's the first time setting up the app you have to set up Administrator privileges to change any settings while using the app. This prevents others from changing your settings unless they have your password.
      From the monitor page hit the + in the upper right corner of the screen. Click the + and then select Administrator from the drop down menu. It will ask you for a password and you'll want to input this password 135790123 the first time. This is the password key selected by the manufacturer. Once you hit confirm you can now make setting changes via the app. Now you may select the + again and select change password from the drop down menu if you want to change to a custom password of your choice. Hope this helps you out.

    • @tedy2009tedy
      @tedy2009tedy Рік тому +1

      You're one of a kind dude! Thank you so much! It worked and I changed the password into my password. I appreciate your effort! Thank you!

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому

      You're welcome! Glad to hear you got it set up! If you ever need to find that code again you can google search "renogy home app password" and it will usually pull it up for you. I'll also put that password in the description of this video so you'll be able to find it there. 👍

  • @jeremyruff7961
    @jeremyruff7961 5 місяців тому

    Is there a wifi option available?

  • @toculucian9340
    @toculucian9340 Рік тому +1

    hi, i have a problem, and i see.... a lot of people have the same problem..... i have a Controller Renogy Rover Li 20 A, and i buy 2 batteries LiPo4 X 100Ah each.... bluetooth from bateries, shows me 40% and the other one 46% , and ontroller shows me always 100% ......controller settings are on Li battery standard.... if i put any other keind of batery (not LiPO) will show the real batery status, if i put a LiPo battery...shows always 100%...Renogy support.....is really slow....and not so helpfull.... what i must do?

    • @DIYHomesteadProjectsDIYHP10
      @DIYHomesteadProjectsDIYHP10  Рік тому +2

      I’m not positive but I think the battery needs to be charged to full capacity first. Then from there the percentage should read accurately.

    • @toculucian9340
      @toculucian9340 Рік тому +1

      @@DIYHomesteadProjectsDIYHP10 i will try this too, and i will wrote if goes or Not....because a lot of people have the same problem ...and..Thank u a lot !!!send u my greetings

    • @toculucian9340
      @toculucian9340 11 місяців тому +1

      @@DIYHomesteadProjectsDIYHP10 i contact Renogy support and they say the controller SOC is not accurate... also....will never show the LIPO4 percent....

    • @AdvantureRoad
      @AdvantureRoad 28 днів тому

      @@toculucian9340I’m having the same issue, with the controller always showing 100%. Settings are set to Lithium batteries. Sounds like I’ll be buying a separate battery monitor. Thank you

  • @richardkessenich2334
    @richardkessenich2334 Рік тому

    The manual sucks…lists abbreviations for all battery types without an index to what they mean for us that dont know. I’m unable to even get to the battery type screen??? I have standard flooded lead acid batteries , not sealed… what’s USE? I’m assuming FLD is what I want but cannot find a way to select!

  • @RichieKeane
    @RichieKeane 13 днів тому

    Terminals are really poor but good unit

  • @rv10flyer84
    @rv10flyer84 7 місяців тому

    Disregard his 100 Amp Battery or PV Input.
    He meant 100 VDC Maximum PV Input.
    Maximum Battery Input Voltage is 32 VDC.
    Max Output to Battery 40 A.

  • @raystanton238
    @raystanton238 Рік тому

    My friend just bought this charge controller and overall it seems pretty good but, those little (microscopic) icons for battery types, not allowing a choice in temperature display between Celsius or Fahrenheit and no backlighted display means I would not recommend this charge controller to anyone else. There are lots of other brands to choose from. I like the EPever with the T-50 back lighted remote.

    • @ThomasTheFapEngine
      @ThomasTheFapEngine Рік тому +2

      Considering I got these for $150AUD each and I'm Australian, and I wear my glasses like Ray and Mr DIY Homestead Projects should probably do more often, I definitely CAN recommend this to others :)

    • @jeffclark5268
      @jeffclark5268 Рік тому +4

      Not being able to set the temperature units to rocks and sticks units should not hold you back from getting one of these.

    • @cmacclel
      @cmacclel 11 місяців тому +1

      LOL like how often are you going to be starring at a screen? It' s not a TV or monitor plus you have the app.

  • @allbo-nov9992
    @allbo-nov9992 Рік тому

    Just what you need, did not explain…

  • @magealexstra
    @magealexstra 8 місяців тому

    That's not the official renogy app

  • @evertmcilwain
    @evertmcilwain 10 місяців тому +1

    US is the only country that has not moved from Fahrenheit to Celsius. Time to learn Celsius

    • @madmagrider
      @madmagrider 6 місяців тому +4

      Time for another country to land humans on the moon.

  • @djwaffle
    @djwaffle 3 місяці тому

    Over on Gul Madred's channel he said there are 5 lights.