Це відео не доступне.
Перепрошуємо.

OMTech 5200 / 5202 - Constant Temp Mode Settings

Поділитися
Вставка
  • Опубліковано 7 сер 2024
  • I like to keep my chiller in constant temperature mode so that I know that my laser is in a safe operation temperature. This video shows how to program these setting on you OMTech CW 5202 or CW 5200.
    Chiller settings:
    To enter programming press the UP button and set button for 5 seconds until 0 is displayed. Then enter the passcode "08" or "0.8", press SET
    F3 "Constant Temp Mode"- 0
    SET
    F9 "Lowest Water Temp" - 16
    SET
    F0 "Water Temp" - 18
    SET
    RST
    At the end of the setting press the RST button to save all settings and exit to operation.
    Here is the chiller manual for reference.
    cdn.shopify.com/s/files/1/028...
    Affiliate stuff:
    Chiller:
    omtechlaser.com/collections/a...
    OMTech Lasers:
    omtechlaser.com/LGS
    Affiliate code “LASERGUYS”
    Coupon code “LASERGUYS5OFF”
    Amazon Affiliate Products
    Amazon.com/shop/beardedbuildsco
    Laser Blog:
    beardedbuildsco.com/blogs/las...
    OMTech Facebook Group:
    / 1364016877267714
    Socials:
    beardedbuildsco
    Facebook.com/beardedbuildsco

КОМЕНТАРІ • 63

  • @davidspyres
    @davidspyres 3 роки тому +22

    Hey Brandt.....you also need to press the RST button once you are finished with all the changes. I didn't and it did not save the changes. Just a heads up! 😎

  • @ChipperoniD
    @ChipperoniD 2 роки тому +2

    Thanks man, you've really helped me along the way. Truly appreciate you taking the time to cut a trail for us coming up behind you.

  • @michaelsfabwork2985
    @michaelsfabwork2985 Рік тому +1

    Just got my chiller today so im going to try and get it set up. I will be following your video for the set up. Thank you. Take care and stay safe. I subscribed as well.

  • @tylerwiltsey6447
    @tylerwiltsey6447 2 роки тому +1

    Couldn’t have setup my laser without your videos 👍

  • @timetempest
    @timetempest 2 роки тому

    Thank you for a quick and concise guide! Straight to the info I needed. 🙌🏻🙌🏻🙌🏻

  • @michaelmargherio1716
    @michaelmargherio1716 2 роки тому

    Excellent to the point video, Thank you!

  • @Rover0010
    @Rover0010 7 місяців тому

    Thanks, don't know why OmTech doesn't relay this info on their web site, but your video was great and I hope that resolves my E3 Error.

  • @j-wings
    @j-wings 11 місяців тому +1

    Note: for the CW-5202 I just purchased this week, this still works, but to activate the advanced control mode, you have to push the up arrow SLIGHTLY before you push the set button.

  • @dgoddard
    @dgoddard 2 дні тому

    Dude, you rock. I've been messing with this thin (newer CW-5200) for the last hour. The Chinese make great products, but they really need to hire someone who speaks English to write their manuals. LOL Thanks, bud.

  • @creationsbyjni3858
    @creationsbyjni3858 Місяць тому

    🎉🎉🎉🎉 love it thank you

  • @SkullyWoodMetal
    @SkullyWoodMetal 3 роки тому +1

    Thanks for the help and clarification. I have the 5200.

    • @BeardedBuildsCo
      @BeardedBuildsCo  3 роки тому +1

      You’re welcome! Glad I could help!

    • @khertler
      @khertler 3 роки тому +3

      Can you describe a little more what these two settings actually do? I just received my first laser a couple days ago and I’m trying to understand as much as possible. Thanks!

    • @BeardedBuildsCo
      @BeardedBuildsCo  3 роки тому +1

      Inteligente mode matched the ambient temperature and constant temp mode will keep the water cooled to the temp that you set.

    • @wrightswoodworks5199
      @wrightswoodworks5199 3 роки тому +1

      Thanks man... super helpful!

  • @jhdesignshouston1469
    @jhdesignshouston1469 Рік тому

    Thank you again!

  • @AceDaPig
    @AceDaPig Рік тому +1

    I found that I needed to set F0 to the water temp I wanted, because the changes made to F8 and F9 I believe are for the automatic mode. But we switched F3 for the control mode to be constant instead.
    I was finding that my water temp was not going to the settings from F8 and F9 until I made the change to F0 to be 18 instead

  • @absolom7691
    @absolom7691 2 роки тому

    Thank you!!

  • @PlanetrightPro
    @PlanetrightPro 2 роки тому

    Hi, just wondering after I've set it up for 19 degrees on constant, the compressor doesnt shut off when it hits 19 degrees? Does it run continuously in constant temp mode. Thx

  • @andyvillegas487
    @andyvillegas487 2 роки тому

    My chiller when set and up are pressed it goes to -2, 0 never comes up. Is there another combo or am I pressing a third button?

  • @mariobrown9812
    @mariobrown9812 2 роки тому

    I just recently purchased the 5202 & it feels like there is water already inside it. Mind you, I purchased it brand new directly from OMtech. Is this normal? I can see & hear it. I just don’t want it to not be distilled or any other fluid not regulated for this device.

  • @deeplyrootedone
    @deeplyrootedone 2 роки тому

    I've followed your instructions, which are great by the way. I even repeated the steps thinking that turning off the power strip its connected to, caused it to revert back to the default settings. However, my chiller still goes above the max temp. Is this normal?

    • @BeardedBuildsCo
      @BeardedBuildsCo  2 роки тому +1

      At the end you need to press RST to finalize all the settings not SET

  • @RussellRay
    @RussellRay 3 роки тому

    How come in the manual on number 6 it says press ret to save your changes and then exit? It says pressing set will not save your changes

    • @phototec
      @phototec 2 роки тому

      Yep, the video instructions are NOT correct (the video should be updated).....IMHO

  • @smattt
    @smattt 6 місяців тому

    I live up north and my machine is in the garage. Guessing I'll need to use antifreeze mixed in with the water - what ratio would you recommend? I have the CW-5200.

  • @chrisbrophy2818
    @chrisbrophy2818 Рік тому

    Setting up my CW5202 chiller with my new Omtech MF2028 60w. Connected lines(no kinks)to inlet/outlet Set A...filled to proper level and turned unit on. UNIT ALARM will not shut off and keeps beeping. Tube filled and do not see leaks. Do I need to set constant temp before alarm shuts off or can there be another reason for alarm. Appreciate any insight.

    • @BeardedBuildsCo
      @BeardedBuildsCo  Рік тому

      Have you made sure that you have your connections correct?
      Chiller outlet ➡️ laser inlet
      Laser outlet ➡️ chiller inlet

    • @WestCoastPrepperRN
      @WestCoastPrepperRN Рік тому

      If you have the 5202, you have to put a short tube on the ports you aren't using if you are just running 1 laser...ie: a short piece of tubing running from the input to the output ports on the back of the chiller as a loop, then run the lines like normal to the laser on the other input/output ports...

  • @angeladelreal9046
    @angeladelreal9046 3 роки тому

    my water tube is building up condensation. what can I do to change this

    • @CHS10901
      @CHS10901 2 роки тому

      The easies would be to get some foam insulation like what is used for insulating copper water pipes in your house. You should be able to get that from Home Depot or any other home store or hardware store.

  • @1010tesla
    @1010tesla 3 роки тому +2

    remember, if you live in a hot humid area a setting too low could cause condensation to form on your tube and potentially arc from the high voltage connection. ask me how I know...

    • @angeladelreal9046
      @angeladelreal9046 3 роки тому

      I live in Texas you just described my weather what do you do about that?

    • @1010tesla
      @1010tesla 3 роки тому

      @@angeladelreal9046 the chillers have a mode where they regulate the water temp relative to the ambient temp. you will have to read that hard to understand chinese manual and work out what temp is right for your conditions while still keeping the tube at a safe temp. I live in oklahoma so we have similar conditions.

  • @Urmo940
    @Urmo940 Рік тому

    My 5200 Chiller temp keeps going up even in constant mode set at 16. I don't know what to do and I am never going to get this thing up and running if I keep running into issues :( I love your videos though!

  • @outragedpi3
    @outragedpi3 2 роки тому

    I sat holding the two buttons for over a minute and 0 doesn't come up. Is my unit defective? Is there a reset?

    • @BeardedBuildsCo
      @BeardedBuildsCo  2 роки тому

      Did you hold the correct two of the four buttons?

  • @randytaillon3818
    @randytaillon3818 3 роки тому +1

    I noticed you seem to have defeated that annoying chirping. Can you share how that was accomplished.

    • @BeardedBuildsCo
      @BeardedBuildsCo  3 роки тому

      Right here…
      ua-cam.com/video/U6LhuwpaxAU/v-deo.html

    • @randytaillon3818
      @randytaillon3818 3 роки тому

      @@BeardedBuildsCo I saw that one already. I'm talking about the chirp from the chiller alarm.

    • @BeardedBuildsCo
      @BeardedBuildsCo  3 роки тому

      A chirp from the chiller is not normal operation. Are you getting normal flow? Does it seem like the water is pulsing?

    • @randytaillon3818
      @randytaillon3818 3 роки тому

      @@BeardedBuildsCo I assumed it was announcing a swing in temp like the controller for my AC mains heatbed controller on my CR-10 with 750w bed heater. I followed the tube routing inside the machine and found a kink in the line at the Y. The kink was caused by a short run of tube that was actually too long. Chirp eliminated. Thanks for putting me on the right path.

    • @BeardedBuildsCo
      @BeardedBuildsCo  3 роки тому

      Awesome! Glad you got it figured out!

  • @tiffsdecorandmore
    @tiffsdecorandmore 2 роки тому +1

    I press and hold and nothing happens

  • @fellowshipsquareseniorlivi1289
    @fellowshipsquareseniorlivi1289 2 роки тому +1

    tried it, no luck. It always showed -0.0 with not just one 0. I unplugged unit and tried again no luck

  • @0711dogs
    @0711dogs 2 роки тому

    My F numbers are not coming up. What am I doing wrong?

    • @gregoryfletcher7170
      @gregoryfletcher7170 Рік тому

      did you ever figure it out ? having same problem

    • @jackbrady7
      @jackbrady7 7 місяців тому

      Me Too...@@gregoryfletcher7170

  • @albertdrew7235
    @albertdrew7235 Рік тому

    Hey Jeff thanks for the info. However when I press both Set & Reset I cannot get it to go to "0".. It starts to count down in two places. Thanks

  • @thogg4
    @thogg4 3 роки тому

    What settings can I use to keep my drinks cold while using the laser?

  • @1haggler
    @1haggler Рік тому

    Would like to know is the Constant Temp Mode necessary? Would running out of box suffice? Just trying to understand the difference, like is it more useful in regions that have extreme temps?
    Please advise
    Thank you

  • @sergiorodriguez1291
    @sergiorodriguez1291 Рік тому

    Literally me pressing the up arrow and set doesn’t do anything

  • @frekuramusicyoutubechannel2961

    Need to press RST to save settings to finish

  • @alicelaser7542
    @alicelaser7542 2 роки тому

    This is a knock off, not a genuine S&A 5200 chiller…