My unit is shutting down and blowing unit main fuse when going to cook something. I checked the monitor switch and it is working fine, but when I put my meter on the wires that were connected to the monitor switch I am getting continuity. So from watching you video, it seems I would have a bad hv cap, bad hv xfmr, bad magnetron or a bad diode/rectifier - correct? Thanks
hi there i have a sage 3 in 1 inverter microwave THAT all works BUT it doesnt MADE A VIDEO ON MY PROBLEM can you help or point me in the right direction NOTE : - i have replaced all 3 thermostat switches BUT I STILL GET THE error message of E - 05 after 40 Seconds or so ! ua-cam.com/video/wXxQZwNJNuc/v-deo.html
Great troubleshooting. Isolate the problem. I like the way you think.
Great stuff here!
My unit is shutting down and blowing unit main fuse when going to cook something. I checked the monitor switch and it is working fine, but when I put my meter on the wires that were connected to the monitor switch I am getting continuity.
So from watching you video, it seems I would have a bad hv cap, bad hv xfmr, bad magnetron or a bad diode/rectifier - correct?
Thanks
If you (Richard) and Scott Brown(Samurai) will join forces and start an institute, you will give CAL-TECH a run for their money!
🧠💡
hi there i have a sage 3 in 1 inverter microwave THAT all works BUT it doesnt MADE A VIDEO ON MY PROBLEM can you help or point me in the right direction NOTE : - i have replaced all 3 thermostat switches BUT I STILL GET THE error message of E - 05 after 40 Seconds or so !
ua-cam.com/video/wXxQZwNJNuc/v-deo.html