Which Smart Energy Monitor Is Right For You? ShellyEM vs Sense

Поділитися
Вставка
  • Опубліковано 21 вер 2024
  • The sense energy monitor and the ShellyEM are both very capable smart energy monitors with a slightly different intended users. This video shows how to install and use them in your smart home.
    Buy the ShellyEM: event.2perform...
    Buy the Sense Energy Monitor: amzn.to/2NW9Nbc
    *As an Amazon Associate I earn a % of qualifying purchases at no cost to you.*
    Node-RED Flow and Clever Code:
    github.com/the...
    Visit my website: www.TheSmartHom...
    Follow me on Twitter: @TheHookUp1
    Support my channel:
    Patreon: / thehookup
    Music by www.BenSound.com

КОМЕНТАРІ • 257

  • @TheHookUp
    @TheHookUp  5 років тому +105

    A quick clarification note: I know the electrons shown in the animation are showing DC not AC current, this is a representation of my video editing skills, not my knowledge of physics. Please imagine that the animation takes place in less than 1/60th of a second :)

    • @MichaelMantion
      @MichaelMantion 5 років тому +4

      I have a pentair 011018. I want to add a chlorine generator and lights and I would like to automate them. I plan to pull a 60 amp line and was going to put a sub panel. Is your pentair panel smart in anyway? I want to be able to control my pool with Alexa. Others have made videos but they are kinda lacking in details.

    • @seraphina985
      @seraphina985 4 роки тому +1

      While it would be a complete pain I can't help but wonder whether shutting everything off and individually toggling a single device at a time a few times may increase the likelyhood of detection with the sense. At least, in theory, it would improve the signal to noise ratio for the device you are trying to get established by eliminating the noise on the power line caused by other devices. By the way trying to get things like computers with switched-mode power supplies and load-dependent consumption to be detected as baseload is likely to be tricky however you do it.

    • @livinthedream1525
      @livinthedream1525 4 роки тому +2

      Love the video. One quick note tho, in the US the phases are not 180 degrees from each other. It is simply a different transformer winding that is in phase with the first. That’s why it’s called single phase power. That’s a common misconception that even most electricians don’t fully understand. I’m an electrician and just had this conversation with some co workers a few weeks ago.

    • @rdpecken
      @rdpecken 3 роки тому +6

      @@livinthedream1525 , I disagree about the phases being "in-phase" with each other. I am a retired electronics technician with over 40 years experience working for large generation, transmission and distribution power companies, and have observed on an oscilloscope many times that the two phases are indeed 180 degrees out of phase with each other. We use 240 volt split-phase feeds in the US. For small residential buildings, the usual method is to rig up a 240V stepdown transformer (instead of 120V) in which the secondary winding is split into two 120V windings (hence the name "split phase"). The center tap is then grounded and fed to the house as if it was the neutral wire of the old 120V system, and each end is wired as a separate 120V live wire. Their waveforms have a half-cycle offset, or 180 degrees, when measured against the neutral wire. (credit:appliantology.org/blogs/entry/606-explanation-of-120v-single-phase-240v-split-phase-and-208v-3-phase/)

    • @WanderlustWonderscape
      @WanderlustWonderscape 2 роки тому

      If you want to really get into the physics of electrons, check out ua-cam.com/video/bHIhgxav9LY/v-deo.html

  • @mikescott58
    @mikescott58 3 роки тому +3

    I ordered the ShellyEM and didn't realize it shipped from Switzerland.
    I placed the order on November 21 and it shipped on the 23rd.
    It wasn't received by the USPS in Chicago until December 16 and was finally delivered today making the delivery time a little over one month!
    Looking forward to hooking it up to my EVSE to monitor energy used to charge my car.

    • @rockstardonut777
      @rockstardonut777 Рік тому

      Switzerland, are you sure? The shelly shop is showing an address in Bulgaria. And i believe Shelly is a Chinese company.

    • @TheHookUp
      @TheHookUp  Рік тому

      Shelly is a Bulgarian company.

  • @BroncoPatriot
    @BroncoPatriot 5 років тому +4

    I don’t have the issues you experienced with Sense. I have over 40 devices showing up and only 5 of them are incorrect over the past year. The Shelly or any other solution is very costly when you decide to monitor more than a few devices. It is all about what you really want to monitor. I needed 6 devices to be monitored and the Sense was the most cost effective solution but took 3 months to benefit from that “investment.”
    Also, you have limited space in your panel so to have multiple “clamps” with devices inside your panel could be dangerous and can be a nightmare to manage connectivity.
    You are right though that Sense is hyped to be this great solution to discover devices but it does take a long time to do it and each home is different with line noise due to location, installation and quality of feed wires.
    Overall, this area of smart tech isn’t very smart and has seemed to be very costly for those of us who would like to be more eco-friendly and curb our usage patterns. If the Shelly could be even more lower in cost similar to the switches then we would be able to monitor the right amount of devices without spending a ton of $$$.

  • @TheJeffesterline
    @TheJeffesterline 3 роки тому +3

    You need to look at the Emporia Vue 2nd Gen. I have only had it installed for 3 weeks, but the information it provides is amazing. It uses a sensor for every circuit, up to 16, and you can use more than one unit if you have more than one panel. They have smart outlets to get more info about a monitored circuit , or monitor individual plugs in your home that are not monitored in your electric panel. No machine learning. I don't know about extracting your data, as I don't have a desire to use that feature.

    • @shubinternet
      @shubinternet 3 роки тому

      I’m also curious about the Emporia versus the Sense. Please let us know how it goes!

  • @paulfontaine7819
    @paulfontaine7819 2 роки тому +6

    Of course your second AC is difficult to detect for the Sense: both ACs have the same power signature, it is very difficult for the Sense to distinguish them. I have the same issue with all my devices of similar power (signature)

  • @samuraiintellectual
    @samuraiintellectual Рік тому

    The sense was a great idea. After 3 years of having it installed I now have “35 motor” notifications with very little information on how to determine what it actually is. The concept of crowd information to determine what’s what I thought was a great idea, however I don’t think they have enough installations to make that work. I had to turn off all notifications from the app as I was getting constant “a new motor has been detected” messages.

  • @AugmentedPixel
    @AugmentedPixel 4 роки тому +2

    I do building controls for DSG,Wallmart,Ikea ect. and they use the same type of product but also use smart breakers so that they can remotely turn off breakers and lights. Its pretty cool and easy to program

    • @aleonyohan6745
      @aleonyohan6745 Рік тому

      I work on large commercial HVAC systems. I have seen many large rooftop units running when they shouldn't be due to various reasons. I found a monitor that cost $300 per rooftop and can be simply installed no matter how old the unit is. Any advice on how to pitch this to the building owner?

  • @nstevenson02
    @nstevenson02 Рік тому +1

    Ever consider a refresh on this topic with the newer and cheaper equipment now available?

  • @ChaseCares
    @ChaseCares 3 роки тому +10

    I would love to see an update about the Sense, do you still use it? Are there still a significant amount of devices that aren't picked up? and are there any features that improve the product since you last reviewed it?

    • @RPostWVU
      @RPostWVU 3 роки тому +2

      I would too. So many more systems now: IoTaWatt, Neurio,Smappee, Efergy, Curb, Vue, Eyedro.

  • @bigfan007
    @bigfan007 2 роки тому +3

    Great, detailed review. Machine Learning (Sense) us still pretty immature, despite all the media hype. It is a shame they do not allow a common sense manual approach to identify problematic devices.

  • @txcas
    @txcas 4 роки тому +17

    How about an updated review using the Shelly 3EM?

  • @jqzIII
    @jqzIII 3 роки тому

    I got my smart energy monitor for $20.
    Just a lil ltr-sdr dongle I bought on Amazon and connected to my Pi³.
    Sniffin' my electric meters RF signal.
    It was fun. Counts every last kWh too.

    • @jqzIII
      @jqzIII 3 роки тому

      @420 Gaming Here's one... ua-cam.com/video/lkEfJkDTQIQ/v-deo.html. btw... My meters don't have any visible antennas. But still they send out radio. I have yet to get my water meter into HA. It's too far and buried underground a bit. Oh well.
      Have fun.

  • @kenrodriguez9645
    @kenrodriguez9645 4 роки тому +1

    Emporia Vue is best of both worlds. Measures the mains, and measures 8 breakers with CTs. Install is as easy as the Sense but none of the guesswork. Directly measuring my pool sub panel, Upstairs AC, downstairs AC, Laundry room, kitchen/fridge, office, and 2 other breakers directly. Software is transparent, no coding or learning curve. $100 - lot better deal than the Sense.

    • @TheHookUp
      @TheHookUp  4 роки тому +2

      I might have to take a look at that, the Sense is probably the most worthless device in my home.

  • @DethpickleDave
    @DethpickleDave 5 років тому

    Awesome as usual. Folks in SoCal, don't over look using the rainforest eagle energy monitor. It can join your zigbee network to intercept the continuous power messages sent out by your utility's smart meter. It offers some cloud stuff, but also a local push that pretty easily goes into NodeRed/HA as well.

    • @TheHookUp
      @TheHookUp  5 років тому

      The dream! An open protocol energy meter would be amazing.

    • @hgelpke
      @hgelpke 5 років тому

      How do I get in on this? I'm an Ladwp customer

    • @DethpickleDave
      @DethpickleDave 5 років тому

      @@hgelpke No idea on your specific utility. I'm on SDGE and setup was trivial. The product is here: rainforestautomation.com/rfa-z114-eagle-200-2/

    • @hgelpke
      @hgelpke 5 років тому

      @@DethpickleDave How did you get the smart meter? Is your home newer or did you get it installed?

    • @DethpickleDave
      @DethpickleDave 5 років тому

      @@hgelpke A few years ago SDGE rolled it out to all of San Diego. No more meter reading for them. The opportunity of Demand Response programs and OhmConnect for us. It just happens that the meters speak Zigbee and Rainforest makes a gadget for listening to it. I'd start with your utility and see if they have anything like it (or if you already have it).

  • @fariddergal1265
    @fariddergal1265 Рік тому

    HI 8b my region we use 2 120v lines and they have different phase from each other , so to be accurate measuring each line, I had to put a single Shelly per line , to that the reference voltage is the same than the line measuring , that's the only thing you need to consider. great video thanks for sharing

  • @MehrdadGivehchi
    @MehrdadGivehchi 5 років тому +6

    Thanks for the video... I have both Sense and IOTAWATT and highly recommend IOTAWATT as this product is simply awesome and full of features.

    • @scottbrown4611
      @scottbrown4611 5 років тому +1

      IoTaWatt is a great Open Source tool. I have one and would recommend it over these two.

    • @frederickmack9655
      @frederickmack9655 2 роки тому +1

      Do you have a link to the product?

  • @jensschroder8214
    @jensschroder8214 Рік тому

    it makes sense to connect the Shelly 2EM to 120 volts with split phase, with an angle of 180°
    240 volt devices will draw power from both current sensors.
    120V devices will only show power to one current sensor. One current sensor needs to be reversed.
    It doesn't work that way on a three-phase current with an angle of 120°.

  • @boogermeats
    @boogermeats 2 роки тому

    This is a great video showing the features & shortfalls.

  • @DmitriyKhazansky
    @DmitriyKhazansky 5 років тому +1

    You should refer to the breakers as one pole or two pole and not 120v/240v. Both of those QO breakers are actually rated for 240v applications. I’m knit picking, but you are a teacher so I figured you’d want to know.

  • @tom95521
    @tom95521 6 місяців тому

    I have 2 consumption monitoring devices. Enphase CTs (part of solar install) and Emporia Vue Utility Connect to read smart meter data.

  • @hannuhanhi183
    @hannuhanhi183 Рік тому

    Here in the modern world we use smart energy meters pulse output to measure the whole house electricity consumption. One esp32, one phototransistor some code, cost 10 € :)

  • @VolgClawtooth
    @VolgClawtooth 4 роки тому +1

    Correct me if I am wrong, but it would seem that you could literally install the Shelley EM in parallel with your desired device's power cord.. say in in an outlet and thusly monitor exactly the appliance you want.. granted this solution quickly surpasses the Sense cost if you monitor more than five outlets.. but for the control and granularity..

    • @TheHookUp
      @TheHookUp  4 роки тому

      Yeah, the sense is definitely going for the "minimum wires, single location" approach, which sounds cool in theory, but in practice it has mostly been a failure.

  • @dannydoolhoff4215
    @dannydoolhoff4215 Рік тому

    The biggest problem for some people with the discovery of new items in the sense, is some people have multiples of the same item.
    2 fridges bought at the same time and of the same model for example can be seen as the same device, at least at first, if on the same half of the split phase circuit.
    Multiples of the same A/C unit can also be problematic at best for proper discovery.

  • @bytenik
    @bytenik 10 місяців тому

    This is a common misconception; US split phase power is not 180 degrees out of phase. It is in phase. 180 degree out of phase power would result in 0V when the two phases are combined. Instead you are using a single phase with a center tap at the transformer. The voltage is only -120V when you reference against the center tap. In reality, it would be better to mark the wires as 0V, 120V, and 240V. The potential difference between the 0V and 240V is 240V, whereas the potential difference between the 120V and 240V is 120V, hence a second 120V "leg."

  • @ulkesh78
    @ulkesh78 5 років тому +15

    Odd that 2 of your device types it won't discover happen to be "duplicate" device types, 2 fridges, 2 AC units...

    • @TheHookUp
      @TheHookUp  5 років тому +4

      I'd be willing to bet it is the root cause of the problem.

    • @Allclear75
      @Allclear75 5 років тому +1

      Not really odd if you understand what Sense is trying to do. Most houses only have 1 AC Unit and fridge, so once Sense algorithms find the first one the algorithm looks for the next best match, because it's not logical to have two generally.

    • @Mrcaffinebean
      @Mrcaffinebean 5 років тому +1

      The Hook Up are the refrigerators the same make and model?

    • @Mrcaffinebean
      @Mrcaffinebean 5 років тому +2

      Justin Spade it’s not all that uncommon, especially having two fridges. I wonder if it’s that they have an inability to distinguish them or if like you said they are making the assumption they are the same. If it’s the latter then a discovery process that he suggests would solve that problem as well.

    • @TheHookUp
      @TheHookUp  5 років тому +1

      @@Mrcaffinebean Very different fridges. One nice samsung fridge, 1 cheap sears brand fridge.

  • @Griswald2000
    @Griswald2000 3 роки тому

    I purchased the sense a couple years ago as I wanted to monitor my hot tub. It did find the hot tub in a reasonable time frame and now has 46 devices. It isn't perfect but it fit my needs. I am interested in the Shelley as we may be moving and won't have a hot tub in our new place.

  • @seanc4877
    @seanc4877 2 роки тому +2

    I have the Emporia and it does a great job, albeit using a Cloud to aggregate data. Unfortunately, I have several panels so need more customization than it can support. I’d like to consider the Shelly device but I wasn’t clear if those can share the reference breaker otherwise it seems like a nonstarter as I can add reference breakers for each Shelly EM. I have a main 400amp service then 3 separate panels in different areas of my home which makes this challenge.

  • @MoeBabaloosh
    @MoeBabaloosh 2 роки тому +1

    Couldn't they learn faster with a circuit chirp? Induce a unique frequency through the power cord and assist the machine learning to recognize faster?
    Also, nicknames or enable editing on device nomenclature for easy ID for the end user?
    These features/capabilities don't seem to difficult to add on...I wonder why MFR doesn't offer?

  • @Allclear75
    @Allclear75 5 років тому

    Sense is compatible with TP-LINK HS110 Smart Plug w/Energy Monitoring and Kasa Smart WiFi Power Strip by TP-Link - 6 Outlet Surge Protection, so if you have hard to track loads like computers and TV's these will communicate with Sense & show up in devices.

  • @vk3fbab
    @vk3fbab 5 років тому

    I have used a lot of Schneider electric monitoring. Their gear is great because it can be either 3P or 3x1P. I'm in Australia hence the the use of single and 3 phase. However you need to ensure that your V and I are on the phase because it actually multiplies the instantaneous V and I. So if you cross phases it will be very wrong. I have crossed phases before and you get really wrong results. This could also be happening with the Shelly but not sure as I've never used their gear.

  • @XzTS-Roostro
    @XzTS-Roostro 4 роки тому +1

    The Sense was featured on Ask This Old House

  • @kabturek
    @kabturek 5 років тому +9

    fancy computer magic is called NILM (Non Invasive Load Monitoring) - there is a research paper about it

  • @anikogerdes9404
    @anikogerdes9404 5 років тому

    I don't know much about US home electricity, but I want to mention that if your devices are connected to the mains by regular wall sockets or power strips, then you can use Tasmota-capable switchable plugs that can also measure voltage, current, and power (including reactive and apparent power) for less than 10€ per piece. With all the Tasmota benefits like MQTT integration that you already know. You only have to flash these Tuya devices. At that price, 1 plug per device is that you want to measure is very affordable and it saves you from messing with the breaker box and enables remotely switching the device on and off, too. Max amps of the plugs may be a limiting factor.

    • @TheHookUp
      @TheHookUp  5 років тому

      Yeah, amperage is going yo be the limiting factor. No plug is going to be able to handle an air con compressor or heat pump.

  • @1964davidsable
    @1964davidsable 3 роки тому +2

    For a guy who talks about safety, you do know you're suppose to have minimum clear space around your main panel for safety.

    • @beckyschwantes5287
      @beckyschwantes5287 3 роки тому +2

      Well, what is the clearance specification? You can’t tell the guy he needs to have blowout clearance around his panels and not tell him what it needs to be?

  • @paulrichmond6903
    @paulrichmond6903 4 роки тому

    Have you looked at the TED6000? It will handle 2 & 3 phase supplies and will allow you to combine sensors. It maxes out at 1 MCU, with three mains sensors, and up to two Spyder modules, each able to monitor 8 sensors. I’ve been using mine for a couple of years now and am just starting to integrate it with a home automation system.

  • @james10739
    @james10739 9 місяців тому

    If the air conditioners are the same it seems like it would think they were the same device but ya you should be able to add things which I assume has been added now

  • @vladimir0700
    @vladimir0700 2 роки тому

    Of course, that’s for the 120A unit. Isee that the 50A model is $60

  • @MarcoRagonesi
    @MarcoRagonesi 5 років тому

    Have a look at smappee. It has the ability to learn a new device if you turn on off 3/4 times.
    Unfortunately the closed local API access so there's no more access to the discovered devices to HA. They maintained local mqtt access so you still have access to overall power consumption

  • @tonywebb9909
    @tonywebb9909 Рік тому

    I guess the Shelly is a bit more European by design. The EM can use 120amp CTs, it's good for a garden lighting panel, where you can save money by switching out circuits out unnecessary times with the Shelly relays. I used the MQTT to integrate with my Control 4 system, but also is not 100% yet

  • @avhound2
    @avhound2 4 роки тому

    " Very bad things are going to happen". I died laughing at that simple comment. And if I hadn't already been a subscriber, that would have been good enough to get me to subscribe. That was hilarious.

  • @MeisterQ
    @MeisterQ 5 років тому +2

    Wow. As a german this circuits and breakers looks like its from stone-age.
    But at all, very good and nice video.
    I would always prefer the shelly. I dont like this auto-discover thing.
    Oh and about the MQTT-Topics:
    Im getting the topics where you told you never got them. The shelly is sending them each 5minutes or so i think.

    • @TheHookUp
      @TheHookUp  5 років тому

      Oh nice, maybe I didn't monitor those topics long enough. I wonder why they are sending reactive power so infrequently since it's just as important as total power.

    • @darthtater
      @darthtater 5 років тому

      What do German circuit breakers look like?

    • @MeisterQ
      @MeisterQ 5 років тому

      @@darthtater Google for ABB circuitbreaker.

  • @ehabbarouki9081
    @ehabbarouki9081 4 роки тому

    Hello, I agree with you in that it seems frustrating that you can't manually add devices/appliances around your home and have to wait on Sense to pick it up (if it ever does). Have you tried out some of Sense's competitors, such as Neurio? It seems like a clean app, and there looks to be a way to put the app in "training mode" and add appliances manually. I was just hoping you'd be able to provide some more input on other products that may offer "total home" easy setups but have more flexibility in setup/app customization. Thank you for your feedback!

  • @brentonolander7244
    @brentonolander7244 5 років тому

    I own a sense and like it very much. Their software is very good as you point out. Your criticisms are spot on, however. I think people have been complaining about their closed down discovery process for many years and nothing has been done, so I don’t expect any improvements soon. I sometime wonder if the “electrical signature” they talk about is any more sophisticated than your node red flow logic for the Shelly.

    • @TheHookUp
      @TheHookUp  5 років тому

      Oh, it's much more sophisticated I'm sure.

  • @kwaradio22
    @kwaradio22 Рік тому

    Hey Rob, any plans to update this topic? I'm considering my options and wondered if you've learned more in the past few years.

  • @MW-sv1dp
    @MW-sv1dp 3 роки тому +1

    Don't waste a breaker, double that s*** up!

  • @Adrian-vd8rm
    @Adrian-vd8rm Рік тому

    I love this video :) dude just flexed so smoothly all over the haters by informing them that he gots two ACs and two fridges, two stories but with his two eyes, he cant see you poor hating pheasants :))

  • @Coollision
    @Coollision 3 роки тому

    Hey @The Hook Up , I would love to see an explanation on how the device detection code works!

  • @ericl4160
    @ericl4160 3 роки тому +1

    New Subscriber... I was hoping you did a follow up video on Node-Red Code you use with ShellyEM. I am trying to integrate into my Home Assistant and Ted5000, but it's only picking up the first element. Do you have more documentation anywhere?

  • @automationamateur4650
    @automationamateur4650 5 років тому +4

    Great Video. I would love to see the explanation of the logic in the code at the end of the video.

  • @iannecj
    @iannecj 5 років тому +1

    Although you may have said this....for me the fundamental difference is you cant monitor at the 120/240 split phase panel level with the EM (because its one one single phase at a time) so its Sense at the main panel and EM for loads for me. was interesting that you can put one of the (2) 120V mains on the devices neutral connection allowing for 240V single loads to be monitored. I dont see it in manual. I would think in places where you have 240V line to neutral that is the norm for this device to get 240V. Are you coordinating with the manufacturer on this install mode? in any event, Love your stuff. Ive been an electrical power engineer for 30 years but I'm a novice home automater, microcontroller tinkerer...and Ive learned alot from your videos. Wanted to say thanks.

    • @TheHookUp
      @TheHookUp  5 років тому +1

      Yes, I contacted Shelly about all of these install options and got the green light from them.

    • @ChrisMacaluso
      @ChrisMacaluso Рік тому

      @@TheHookUp Do you know if this is still OK to wire the EM this way for US split phase usage? I am planning a project to monitor two HVAC loads and would be able to use one EM and two 50A clamps in total for this project if that is the case. Your video is literally the only documentation I can find online that mentions allowing 2x 120v mains to be connected at L and N and a clamp to be placed around one of the two phases going to the circuit you want to monitor.

  • @JonCherba
    @JonCherba 4 роки тому +2

    Could you do an episode using CT's instead of a premade system?

  • @TUMARK2
    @TUMARK2 4 роки тому +1

    I was looking for a way to monitor generator load. I have a 30 amp 110 V generator circuit. The shelly montoring system seems like a good fit for this.

  • @efenili
    @efenili 4 роки тому +6

    Great video, one of the more useful I've found. I've been considering the Sense for awhile but haven't really figured if its worth the cost. There are only so many expensive appliances I have that aren't always on and therefore controllable enough to try and get some energy savings. The ones that are I've already attached individual energy monitors to them for much less $$ than the sense costs and I know exactly what appliance is which. One could question the accuracy of those types of monitors though.
    Im pretty handy but the Sense is easily the way I would go out of these 2. It may have short comings but it's convenience wins the day for me by quite a bit and I think that would be the case for many DIYers as electronics is usually the trickiest thing to learn =)
    I feel like utility companies should supply this sort of thing themselves for free :| It's annoying that one of the main reasons I even want this is to see if the energy company is properly billing me or not :\

  • @anpc86
    @anpc86 17 днів тому

    2024 - what are your thoughts on whole home energy monitoring as they are new options since you did this video.
    I find a lot of people seem disgruntled with Sense. And trying to get shelley em to cover the home is difficult.
    Looking at Emporia Vue

  • @wstewart5532
    @wstewart5532 2 роки тому +1

    Great video! Shelley sounds like a solution that I have been seeking since my original plan of Emporia Vue was foiled by the fact that Emporia requires a connection to the cloud for the app to read any data. My use case is the desire to monitor instantaneous load of my backup generator while it is powering select circuits on my breaker panel. I lose internet when my neighborhood power is out so I can't read Emporia data when the generator is being used. But I do still have local wifi and it sounds like one of the Shelley devices can easily be used to display load on my backfeed wires, correct? I see a lot of Shelley devices on their website now - any that you recommend for this limited use case?

  • @JoseAlcerreca
    @JoseAlcerreca 5 років тому +1

    Awesome video, thanks. How often can you send power data over mqtt? I'd like to see spikes. Does it read the value at a particular moment or does it average since the last read? I guess it does the former :)

  • @krasate
    @krasate 4 роки тому

    Take a look at Efergy engage hub energy monitor too. I 've been using with no issues for several years in 3 phase installations. It would be nice to hear your opinion compared to the other two. Home Assistant integration available too but no per-device monitoring (yet...).

  • @milutzuk
    @milutzuk 2 місяці тому

    Note, Shelly is a Bulgarian company (congrats from Romania, my friends!). That means the EU. EU doesn't have this split-phase system. It has only 3 - 230V phases, which amounts to 400V between two phases. That's why ShellyEM is not the best solution for US use, but it's ok for about the rest of the world. Oh and please, if you're in the US, please don't use Volts and Ampers, I want to see some proper imperial units!

    • @TheHookUp
      @TheHookUp  2 місяці тому +1

      😂I don't think imperial has separate units for volts and amps... maybe I can call them pushies and flowies?

    • @milutzuk
      @milutzuk 2 місяці тому

      @@TheHookUp Oh, that;'s a great idea and I even like the sound of those units! But let's not clutter the system too much with more units like ounce-pound or inch-foot are. We can keep mili- or kilo-. 1 miliflowies = 0.0058147 flowies (Fl) and 1024.687 Pushies = 1Kilopushy (Py). P, F, Pu are reserved for chemical elements, you know...
      On a serious note, thank you, @TheHookUp, for making up my mind. I think ShellyEM is the optimum solution for my HomeAssistant environment and when I say optimum I'm taking into consideration a DIY solution with a SCT-013-000 and an ESP32. Almost all my sensors and actuators are DIY, ESP32-based, but this project would be too big for my almost absent free time.

    • @milutzuk
      @milutzuk 2 місяці тому

      @@TheHookUp Now that's a wonderful suggestion, I really like those units! But let's not complicate this system too much with other units like inch-foot or ounce-pound are. Keep it simple. Use mili- and kilo-. 1kiloPushy = 1024.874 Pushies (Psy or Pusy - because there are no other simpler symbols: P-Phosphorus, Pu-Plutonium, Ps can be mistaken with PS, Ph can be mistaken with pH, Py is dedicated for Python libraries and stuff). And, obviously, don't ask why, 1miliFlowy = 0.00987(3) Flowies (Fo, because F-Fluor, Fl can be mistaken with fL, femtoliter).
      Joke aside, thank you for making up my mind. I already ordered a ShellyEM which I consider optimal for my use case (Homeassistant, Europe, duplex house). And when I say optimal I have in mind that almost all my sensors and actuators are ESP32-based DIY modules with printed enclosures. I could make an energy monitor with SCT-013 type CTs, but at this moment the time is not my friend.
      Cheers, mate!

  • @chrisw.1914
    @chrisw.1914 2 роки тому

    Awesome video! Very informative.

  • @LassiVVV
    @LassiVVV 2 роки тому

    New video idea to review and intergrate Shelly 3EM energymeter to home assistant?

  • @pabloestevezgonzalez5862
    @pabloestevezgonzalez5862 4 роки тому +2

    Are there any alternatives for the ShellyEM? Like Tuya or Sonoff branded.

  • @douglaswright6228
    @douglaswright6228 4 роки тому

    Thanks for the demonstrations! Very helpful. My Comment is: The Shelly US online store is frankly terrible. They don't accept credit cards, They don't ship to the Virgin Islands , and they don't answer the phone. There is a Shelly EM on amazon , that's great but they only offer the unit with 1 CT (good for 120v only). My Question is : Where did you purchase your additional CT's ?
    My application is to monitor energy use at 3 different apartment sub-panels , and on 4-5 additional circuits for HVAC (All are 240v ) I need to apply usage to each tenant.
    So I think I need 7 or 8 EM's and 2 CT's for each one. I'm assuming the app will let me label each EM however I wish. Please advise and Thank you again!

  • @Allclear75
    @Allclear75 5 років тому

    I think in 5 to 7 years Sense is going to live up to everyone's dreams. I have one and while it may not be magical yet, it has taught me enough about my usage to easily pay for itself in a year. The team working on Sense also worked on Human speech recognition, (think Siri and Alexa) it takes time to gather the mountains of data to make it perfect.

    • @TheHookUp
      @TheHookUp  5 років тому

      I agree with this assessment. Data is the key.

  • @gverran
    @gverran 5 років тому

    I would be quite keen to see such a detailed review on the Smappee energy monitor. The fact that Sense does not allow you to teach it is quite a deal breaker. I am hoping Smappee isn't like that. Also, I didn't know that your circuits in the US have a combination of 120v and 240v. Your circuit breaker board looks quite complicated. Here in SA, we are 240v only which I would think makes our circuit breakers a lot less complicated.

    • @TheHookUp
      @TheHookUp  5 років тому

      The breakers are pretty simple once you've seen a few of them. I haven't heard of smappee, I'll be buying an IoTaWatt to test out on the advice of a bunch off commentators.

  • @vladimir0700
    @vladimir0700 2 роки тому

    Be good if you could make a separate version that discludes the basic electrical theory for those that just want the device reviews/comparison. Also, the buy link for the shelly em is dead

  • @E150GT
    @E150GT Рік тому

    I was thinking about the sense but in my area the outside service panel has on the 240v breakers and the inside panel has all the single pole breakers. Im worried it might not be able to recognize the circuits in the inside panel or at least distinguish them from one another

  • @servant74
    @servant74 5 років тому

    There was an article a long time ago (20+ years) that Popular Science or Mechanix Illustrated had on monitoring power using just gross mains power. My wife and I did it manually for a while as an experiment. Without extra equipment, we turned off all non-always on equipment and left the house for an hour, reading the power meter before and after we returned. We did the same for washing a load of clothes, drying them, cooking a chicken, boiling a pot of water, running our heater, and air conditioner, and even our lights and TV. With all this power data, we generated our spreadsheet and graphs (yes, by hand, no computer). We learned a lot.
    With experience writing an app, it should be easy to almost replicate the Sense without the AI. It does take some dedication and sluthing, but it can be done. Some loads are SO small, that they hardly matter (alarm clock), but even your always on TVs and cameras do make for a pretty heavy load, especially if you are doing this in preparation of going 'off grid' or other similar effort.

  • @peaksix_
    @peaksix_ 2 роки тому

    I know this video is a few years old, but can you confirm that your Shelly 240V measurement at 6:13 truly works? It's exactly what I am hoping to do, but Shelly support is claiming it won't, and that I'll need multiple Shelly EMs or a different device. Not sure if they're misunderstanding my intent? Kind of confused...

  • @CosminRotaru
    @CosminRotaru 3 роки тому

    I need a smart plug with energy monitoring to figure out if a device (like a non smart tv or audio system) is on or off on home assistant without controlling the plug. I don't want to turn this plug on or off. I just need to know current flow... Or some sensor to connect directly to raspberry. Help? I can't find such device.

  • @fernandomachado3439
    @fernandomachado3439 4 роки тому +2

    Hello, May I ask you the entities are created in order to use them in Home Assistant Ui?

  • @GeorgeElenaRempel
    @GeorgeElenaRempel 2 роки тому

    Does it also Monitor voltage over time. I have very very bad electricity in my house and the provider ignores the problem, they say there’s nothing wrong

  • @anuadu
    @anuadu 5 років тому

    Energy monitoring and Blinds/Curtain control are two areas that still do not have reliable robust product that can be integrated in to Home automation. Surely someone out there should seize the opportunity and come up with something cool.

  • @Michael-w8v
    @Michael-w8v 2 роки тому

    I wouldn't say Sense is a high quality since it is not gonna detected dishwasher all the time if the powers on other appliances are similar. I work with Automatic Protection System a lot.

  • @aacc3876
    @aacc3876 4 роки тому +1

    Great video! Will you review the Shelly 3EM?

    • @TheHookUp
      @TheHookUp  4 роки тому +1

      As soon as I get my hands on it

  • @boogermeats
    @boogermeats 2 роки тому +1

    Has the discovery been fixed? Are there better alternatives?
    Two legs. Only one phase.

    • @TheHookUp
      @TheHookUp  2 роки тому +1

      Sense device discovery has not been improved. What is your use case?

    • @boogermeats
      @boogermeats 2 роки тому

      @@TheHookUp My well pump/motor has failed in the past. Also, my pressurizer pump/motor.
      I want to be able to alert if either has run more that 5 minutes.
      If it's not picking up all the loads, I'll probably settle with Emporia Energy
      (Later I will add a WiFi breaker with a shunt trip)

  • @xandersnyder7214
    @xandersnyder7214 5 років тому

    What about using the Shelly 1PM on the outlets you want to measure your devices on?
    The only thing I could think of would be for 220v equipment that is drawing over 15amps.

  • @sissymurphy9620
    @sissymurphy9620 4 роки тому

    what about this new wise one that seems easy to use .The only thing in both of my panel boxes I do not have any extra breaker spots .How would these work with that and if I have to borrow power from another breaker how can you tell if it is pulling to much power from what ever that breaker is used for .The electricians here in VA do not seem to understand these devices when I ask them about install of one in my house >My house is all electric and I would like to know when something may be using more power than needed .I have a well and that and the heat pump concern me .

  • @celsiusfahrenheit1176
    @celsiusfahrenheit1176 2 роки тому +1

    Insurance companies would not cover the damages done by DIY homeowners that doing electrical work, at least in Massachusetts. I do not care what people do in their homes but as a licensed electrician I would notify the local inspector and my insurance company if a homeowner would touch my work after I inspected it. Also in my career, I have seen skilled licensed professionals getting hurt for stupid things, accidents just happen sometimes and they can be serious. I will check out the monitors though :) cause I legally can LOL

  • @JosephTammaro
    @JosephTammaro 3 роки тому

    Question. I am renovating my house. Is there a reliable timer that can be controlled remotely? I wish to control outdoor lights remotely.

  • @james10739
    @james10739 4 роки тому +1

    Ya it seems stupid that they dont have a way to add devices manually and let you put in the model and just add it to their data base which would help everyone and make their system better

  • @nappyjim
    @nappyjim 2 роки тому

    General question with monitoring 240v appliances using the EM. So I'm measuring my water heater, I currently have 240v fed into the EM. I then have one clamp over 1 of the lines coming out of the water heater contactor.
    Whatever the EM reads from that one line, do I need to double it? So let's say it says my water heater has used 100kwh so far. Since I'm only monitoring one line, has it actually used 200kwh?

  • @BruhMan_5
    @BruhMan_5 Рік тому

    So with the two 120A clamps, you could essentially use the shelly as a whole home monitor as well. Then you could create a helper where if something is using both phases you could double or halve the values depending on the reference voltage. It should work like this if my understanding is correct right?

    • @GCSol
      @GCSol Рік тому

      His wiring diagram is much different than what I've seen online. I think the Shelly only comes with one 120 amp CT and I haven't been able to find where you can purchase just another one by itself.

  • @kinteseay
    @kinteseay 2 роки тому

    Hey, I wanted to verify that you've actually wired the Shelly as you mention at the 5:48 mark in the video? I'm interested in measuring two 240V circuits in the United States and was hoping to only use 1 shelly device to do it. I keep hearing conflicting info as to if I can power the shelly from both phases of the panel.

    • @TheHookUp
      @TheHookUp  2 роки тому +1

      You'll want the shelly 3em to do that, not the standard em like in this video.

    • @kinteseay
      @kinteseay 2 роки тому

      @@TheHookUp Thanks for the clarification

  • @RixtronixLAB
    @RixtronixLAB 2 роки тому

    Nice video, keep it up, thank you :)

  • @chineseredneck1211
    @chineseredneck1211 4 роки тому

    Have you tried leaving the "discovered" duplicate devices unplugged and see if the "undiscovered" device gets found?

  • @morejelloplease
    @morejelloplease 4 роки тому

    Every hour for 8 seconds, I have a buzzing sound coming from my power meter and almost every appliance and light in my house, what smart energy meter would detect this and show it on a graph or scope? The entire house drops about 1.5 to 2 volts when the buzzing noise occurs. new home, all electric, mostly LED's with compatible switches, and no loose neutrals.

    • @VolgClawtooth
      @VolgClawtooth 4 роки тому +1

      Call an electrician.. Seriiusly, that sounds like something witha bad motor or short is triggering often

  • @bunnymaid
    @bunnymaid 4 роки тому

    No Leakage or GFC? Scary.
    JP is the same, just a bit lower around 100v. And our distributions are usually plastic boxes next to the bathroom!

    • @TheHookUp
      @TheHookUp  4 роки тому

      GFC is on specific circuits, not in the panel itself.

  • @peanut9779
    @peanut9779 2 роки тому

    Are the fridges on the 120 feed? It probably thinks they are one unit and you'll need to separate them in the devices tab

  • @sissymurphy9620
    @sissymurphy9620 4 роки тому +1

    how much power do these use and if they use a lot of power where are you saving electricity

    • @arshamskrenes
      @arshamskrenes 4 роки тому +1

      sissy murphy The CT’s use almost no power. Most of the power draw comes from their processors, which for the Shelly is probably a micro controller like the ESP32. The Sense is probably using a few passive components, micro controllers, and application processor like in an old smart phone. I’d estimate it to be up to 5W. So about $5-10/year in electricity.

  • @hernandez9961
    @hernandez9961 4 роки тому +2

    How that it's been a few months from this review, has the sense recognized more of your devices?

    • @TheHookUp
      @TheHookUp  4 роки тому +3

      I think it might actually be worse now. I'd say 80% of the time I only have 2 energy "bubbles" one for "Always on" and one for "Other".

    • @hernandez9961
      @hernandez9961 4 роки тому +1

      @@TheHookUp That's a total bummer. Thank you for sharing your experiences with us, and I appreciate your thorough videos!

    • @ScottJaitly
      @ScottJaitly 4 роки тому

      @@TheHookUp You've most likely incorrectly installed the sense on the same phase: ua-cam.com/video/s0A7WNOuw0E/v-deo.html&t=260

    • @tayloryslava7002
      @tayloryslava7002 4 роки тому

      i need to monitor just my energy usage. i live in a home that has been split in half...the upstairs unit is a 3 bedroom 2 bath & my downstairs unit is a 2 bedroom 2 bath. My pg & e bill is sometimes $600 so my half would be $300.....but i know i dont use that much energy. I domt have a A/c, a heater, a dishwasher which the upstairs unit does have & my fridge is mu h smaller than the full size fridge is upstairs. what device would you recommens i install?

  • @jblyon2
    @jblyon2 4 роки тому +1

    I'd get a Sense IF and only if they added the capability to turn something on, and then tell the system what you just turned on. Seems like it would be an easy way to greatly increase the reliability of their algorithm. I get that they want to sell a device that you just install and then don't have to do anything else, but it's been years and the accuracy, if it even registers a device at all, is still in the toilet.

  • @cedricpod
    @cedricpod 5 років тому

    the current clamps should/could have internal protection for open circuit condition.

    • @TheHookUp
      @TheHookUp  5 років тому

      Very true, still good practice though.

  • @chrisperrywv
    @chrisperrywv 2 роки тому

    Is this still what you’d use on a dryer?

  • @joedecaria6499
    @joedecaria6499 2 роки тому

    Can you connect to ev charger for the consumption of kwh and calculation cost
    thank you

  • @DudleyaSetchellii
    @DudleyaSetchellii 4 роки тому

    Are you able to EDIT the Sense devices listing if it doesn't recognize devices? Just to tell it you know the name of it for cloud reference and want it distinctly named for yourself.

  • @leopoldomolina1763
    @leopoldomolina1763 3 роки тому

    Hi. What is the sample rate of Shelly EM? 1 min, 3 min, 1 hour ? I’d like it to be 1 min resolution

  • @howellschan
    @howellschan 4 роки тому

    thanks

  • @joseallende8767
    @joseallende8767 5 років тому

    Is there a way to change the endpoint in which communicate to the cloud for the Shelly 2.5?

  • @colby4390
    @colby4390 3 роки тому

    Can you now do PowerX energy monitoring

    • @TheHookUp
      @TheHookUp  3 роки тому

      I've been in contact with PowerX for months now, they are experiencing a lot of production delays and are not ready to ship.

  • @rustusandroid
    @rustusandroid 3 роки тому

    So then why do all my breakers come with accommodations for two sets of wires?