how to program runtime on a Centurion D5 Evo Gate Motor

Поділитися
Вставка
  • Опубліковано 10 сер 2022
  • In this episode, we go through runtime/limit setup on the Centurion D5 Evo Gate motor
    Channel sponsors:-
    Rsec Security Equipment Center
    www.rsec.co.za
    / rsecequipmentcentre
    / rsecsecurity
    Music:- Metro - Yung Logos (No Copyright Music)
    Link to Products
    rsec.co.za/product/d5-evo-dom...
    Please comment, like, share and subscribe to the channel
    Follow me on Instagram:- @Nicks_nd_Tricks
    Follow me on Facebook:- / nicksandtricks
  • Наука та технологія

КОМЕНТАРІ • 7

  • @mpho5856
    @mpho5856 Рік тому +2

    After doing that process it still says no setup found

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому +1

      Hi Mpho, try reset the controller and try again please. If no luck, you have to inspect the card for damage

  • @charlesmulenga1237
    @charlesmulenga1237 9 місяців тому +1

    how do we an locked holiday lock out

    • @nicksandtrickssa
      @nicksandtrickssa  9 місяців тому

      Thank you for the comment, do you need to know how to get rid of holiday lock?

    • @nicksandtrickssa
      @nicksandtrickssa  9 місяців тому

      Bridge a piece of Comms cable between common and lockstop, the light must be on to bypass holiday lock

  • @desconhecido7489
    @desconhecido7489 3 місяці тому

    How i can find the error: no orginal setup find?

    • @nicksandtrickssa
      @nicksandtrickssa  3 місяці тому

      Thank you for the comment, origon not found can be a doss/loom error.
      When you move the gate past the magnet it should tell you it moved past the origin marker, if it does the you might have a PCB error