HVAC: Supco Super Boost Installation (Supco Super Boost Relay And Hard Start Capacitor) SUPCO SPP6

Поділитися
Вставка
  • Опубліковано 1 жов 2024
  • HVACR (Heating, Ventilation, Air Conditioning/Refrigeration) Supco Super Boost Installation (Supco Super Boost Relay And Hard Start Capacitor) Supco SPP6 / How To Install Supco Super Boost SPP6 / How To Wire Supco Super Boost Relay And Hard Start Capacitor / Supco Hard Start Kit / How Do You Install A Super Boost Capacitor / How To Wire A Capacitor / How To Install a Capacitor / Capacitor Installation / Capacitor Wiring / HVAC Compressor Not Starting / AC Compressor Not Starting
    How To Wire/Install A Hard Start Kit For AC/Refrigeration Systems (SUPCO 3 N 1 Installation)
    • HVACR: How To Wire/Ins...
    Applications:
    Use on any single phase air-conditioner or refrigeration unit
    Low voltage situations
    Hard starting compressors
    Specs:
    Operating Voltage VAC: 90 to 277 VAC
    Recommended Range (HP): 1/2 - 10 Horse Power
    Capacitor size (µF): 130 to 156 MFD
    Torque: 500%
    Features/Benefits:
    PTC Positive Temperature Coefficient Relay and Capacitor
    Easy 2-wire installation
    NATE® Recognized (Course #1867-0002)
    Can be used on PSC type compressors
    Most economic
    UL® Recognized
    Thanks for watching!
    Email: JumperManTech@Gmail.com
    Follow me on Instagram! @JumpRmantech

КОМЕНТАРІ • 49

  • @kastenusa
    @kastenusa 2 роки тому +4

    What the difference between spp6 and spp6E? And why some installers recommend 5-2-1 instead of this . Thank you

  • @leeb.7188
    @leeb.7188 Рік тому +4

    I ordered this, but it seems it’s the wrong item? This only has two wires. My capacitor has three prongs for the following wires: common, herm, and fan. Looks like I wasted my money, and I’m still roasting hot. 😢

    • @NO-END
      @NO-END Рік тому

      the wire with the additional spade goes to common or "C" and the other goes to "HERM". Make sure discharge the dual run capacitor by using an insulated screwdriver and touch c to herm and c to fan making sure you hold onto insulated part of screwdriver.

    • @antonylesten7319
      @antonylesten7319 3 місяці тому

      Will Installing this reduced or cause any damage to the life of the compressor? My unit starts up every time although I do hear a loud noise when it kicks on. But after that it works great. We're in 2024 and the unit manufacturing date is 2006. Just want to make sure this product will not harm my unit as I love how it cools my home in Florida.

    • @stevero2581
      @stevero2581 Місяць тому +1

      Dual capacitor. Use two herm (compressor) and common. No wire on f or fan.

  • @Followmikecold
    @Followmikecold 6 місяців тому +2

    😂😂😂 what if it has 3

  • @robertdavenport9095
    @robertdavenport9095 2 роки тому +3

    Bro I just used it super amazing thanks for the advice and tips. Keep up the great work!!!

    • @yuriigorg721
      @yuriigorg721 2 роки тому

      Unfortunately, he didn’t show where should to connect compressor. Why I need to connect the Booster without compressor. Is it works without compressor? Where is compressor?
      How to connect the compressor to the booster if it have the two wires only ?….
      I wasted my time here ….

  • @jixia676
    @jixia676 2 роки тому +1

    Great vid. Does the existing run capacitor need to be good in order to use this SPP6? Can I use this if there's no run cap in the system?

  • @kK-br7te
    @kK-br7te 2 місяці тому

    Supco spp5 and spp6 tried both even with two new diff capacitors. Fan turns on for like 10 second and then shuts off compressor still not starting …

  • @jonlima
    @jonlima Місяць тому

    Is there any difference in which one I can install on my unit: SPP5 or SPP6? Thank you.

  • @DanielVeron-cc1xi
    @DanielVeron-cc1xi 15 днів тому

    Would that stop my generator from lugging when it starts

  • @izzybell11
    @izzybell11 2 роки тому +4

    Interesting and helpful video. Well presented and explained. Great job JMT

    • @yuriigorg721
      @yuriigorg721 2 роки тому

      Unfortunately, he didn’t show where should to connect compressor. Why I need to connect the Booster without compressor. Is it works without compressor? Where is compressor?
      How to connect the compressor to the booster if it have the two wires only ?….
      I wasted my time here ..

    • @JumpermanTech
      @JumpermanTech  4 місяці тому +2

      @@yuriigorg721 The capacitor is connected to your compressor or motor. You connect this to the capacitor as shown. Thanks for watching 🔧⚡️

    • @JumpermanTech
      @JumpermanTech  4 місяці тому +1

      Thank you Izzy! Much appreciated 🙏🔧⚡️

    • @JumpermanTech
      @JumpermanTech  4 місяці тому

      @@yuriigorg721 You might be confusing this for the Supco 5-2-1 kit where there is a connection at the compressor itself and the 2 power wires feeding the compressor. I have a video on that too

  • @mattalexander8919
    @mattalexander8919 2 роки тому +1

    Does this reduce the lifespan of a compressor in your opinion? I mean if the compressor is “having a hard time starting” it’s probably on its last legs??

    • @yuriigorg721
      @yuriigorg721 2 роки тому

      Unfortunately, he didn’t show where should to connect compressor. Why I need to connect the Booster without compressor. Is it works without compressor? Where is compressor?
      How to connect the compressor to the booster if it have the two wires only ?….
      I wasted my time here ..

  • @MrMaxx-lo8cv
    @MrMaxx-lo8cv 2 місяці тому

    Great video and thanks for explaining it does not matter which wire is plugged in to the terminals. Most people are afraid they have wires backwards etc. VERY WELL DONE!!!

  • @bernardjacobs3359
    @bernardjacobs3359 8 місяців тому

    Can you install the boost capacitor if you only have a two terminal capacitor, like the one in the video, but the fan and the compressor are on the OEM capacitor?

  • @CheaddakerT.Snodgrass
    @CheaddakerT.Snodgrass 10 місяців тому

    I bought one of these 15 years ago as an emergency backup and never needed it until now; thanksgiving week 2023. The refrigerator / freezer had already gone too warm before I noticed. I have the 5 wire version. It was quite simple to install.
    At the compressor the factory starter and capacitor is attached to the side of the compressor. There is a small bent metal wire that wraps around both pieces; it just unhooks from the side you are on. It's meant to hold the capacitor and starter in place.
    The two come off easily, you can probably pull it off by hand but I used a flat blade screwdriver to start prying it off.
    Looking at the supco it has 3 blade female blade receivers on it. I was expecting the comproessor to have blades on it. The compressor actually has small round prongs. When I looked at the Supco terminals I realived they are shaped to accept either blade or the prongs. The directions for which wire goes to which prong are on the side of the supco, very easy to understand.
    The other two wires did not have terminals on them and the instructions said to hook one to either supply line and the other one ges to the other supply line. What this means is the connector coming from the refrigerator plugs into the capacitor normally but in this case you have to cut the connector, strip the two wires (you can do it) and then twist one to each of the wires on the supco. You then need to put small wire nuts on each of the two wires but you could get by with electrical tape in pinch. The supco probably came with wire nuts originally but it was already out of the package and they were lost.
    Tuck the supco in next to the compressor, plug in the refrigerator and it started right up.
    My existing, original from 10 years ago starter was blackened and charred. A new set will not arrive for two days.
    I then searched for supco start capacitor just because and saw this video and figured I would offer my tale of a quite easy repair.

  • @MrEltinieblas
    @MrEltinieblas Рік тому

    Greetings JMT. A subscriber here. I have a True reach in freezer where the compressor is drawing high amps and so it won’t start. It’s a single phase 240volt. I have checked all the starting components; potential relay, run capacitor, and start capacitor and they all are good. I also have checked the compressor windings and they also checked out. And the compressor is definitely not shortened to ground. Do you think I should install this compressor booster in line with the run capacitor to see if it solves the issue before I go replacing the compressor which is over a thousand dollars? Thanks a lot in advance for your reply. And please keep posting more videos. I’m learning a lot watching them.

  • @joef1159
    @joef1159 2 місяці тому

    Will this product work on Lennox 4 tons unit ?

  • @love-bulldogs
    @love-bulldogs Рік тому

    Thank you will be buying a super boost ,well explain "" B

  • @Georgebrandau
    @Georgebrandau 26 днів тому

    Very helpful

  • @MiamiWebDesign
    @MiamiWebDesign Рік тому

    Can I use one of these to help start a window AC unit that I want to power with a 12v battery bank?

    • @ericklein5097
      @ericklein5097 Рік тому

      if the unit is 12V or you have an inverter

  • @donmtbable
    @donmtbable Рік тому

    Thank you so much for the best formal friendly use video

  • @auberthere3737
    @auberthere3737 4 місяці тому +1

    I have a SPP5 can i replace it with a SPP6?

    • @JumpermanTech
      @JumpermanTech  4 місяці тому

      If they are both just 2 wires, you should be good. Just make sure it's rated for the same. Thanks for watching! Stay tuned for new videos every week🔧⚡️

    • @JumpermanTech
      @JumpermanTech  4 місяці тому

      Look into the HP rating and if they match 👍

    • @auberthere3737
      @auberthere3737 4 місяці тому

      I called the manufacturer and talked with a technician for the company of this product and they said it was fine to go up to 6 but do not go from 6 to 5. I'm just so grateful that we have this technology that we can discuss important issues like this thank you so much.

  • @patkelly7839
    @patkelly7839 Рік тому

    i have a 5 ton AC system...what kind of Super Boost do i need?

  • @yuriigorg721
    @yuriigorg721 2 роки тому +2

    Unfortunately, you didn’t show where should to connect compressor. Why I need to connect the Booster without compressor. Is it works without compressor? Where is compressor?
    How to connect the compressor to the booster if it have the two wires only ?….
    I wasted my time here ..

    • @JumpermanTech
      @JumpermanTech  2 роки тому +1

      You are looking for instructions for a different product. I made a video on that too. I will leave a link to that video below.
      3 N 1 Hard Start Kit
      ua-cam.com/video/sem9z0H1QmU/v-deo.html

  • @TheShoes22
    @TheShoes22 6 місяців тому

    Thank you really helpful.

  • @bills6946
    @bills6946 Рік тому +1

    Pay a little more money for the 5-2-1 kit. 2 wire hard starts will usually fail within the warranty period and you will be going back to do a free service call. 5-2-1 kits are much better and have a lower fail rate.

  • @willarddenton4360
    @willarddenton4360 Рік тому

    Thank You

  • @thesilentonevictor
    @thesilentonevictor 2 роки тому

    Interesting and helpful jmt well done

    • @yuriigorg721
      @yuriigorg721 2 роки тому

      Unfortunately, he didn’t show where should to connect compressor. Why I need to connect the Booster without compressor. Is it works without compressor? Where is compressor?
      How to connect the compressor to the booster if it have the two wires only ?….

  • @Eddy63
    @Eddy63 2 роки тому

    Good vid and good explanation ... Thx ...

    • @yuriigorg721
      @yuriigorg721 2 роки тому

      Unfortunately, he didn’t show where should to connect compressor. Why do I need to connect the Booster without compressor. Is it works without compressor? Where is compressor?
      How to connect the compressor to the booster if it have the two wires only ?….

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 роки тому

    👍

  • @grassthief1280
    @grassthief1280 Рік тому +1

    Not a relay

    • @NO-END
      @NO-END Рік тому

      yes it does have one but 3 in 1 has potential relay which operates better by protecting the compressor better.

  • @DifunctedReble
    @DifunctedReble Рік тому

    Very informative. Came here searching for information on this product because a tech installed it on our AC unit, then tried to upsell us on an EAC and APCO unit.
    When we declined he charged us $500 for installation of the SPP6. Amazon shows it for pretty cheap too. Can the cost be attributed to service charge and/or labor?
    Thanks for any input.

  • @Mm-om9ol
    @Mm-om9ol 2 роки тому

    We call these the "ole stick of dynamite " use the k2 potential relay way better