    @simedward0903 Рік тому

    spool valve proble/ I replaced spool valve, but still problem/ cant open

  • @user-tx8ek1hp5r
    @user-tx8ek1hp5r 2 роки тому

    Me experience a valve hunting in mesto positioner using rotary valve, what is the solution of the problem

  • @mr.nizamulhoq851
    @mr.nizamulhoq851 4 роки тому

    Dear sir,
    have a good day.
    i have recently facing problem in a a newly buying Siemens PS2 positioner connect with
    existing Single acting linear actuator , 20mm stroke.during comissioning this
    new control valve/actuator in initial condition its display shows P 85
    and NOINI mode, at that time when i press + and - button the actuator
    totally not move.only small sound hearing inside the positioner and some air
    release backside of positioner , however pneumatic and electrical connection is
    ok.if i place old existing positioner there then it easily move
    the actuator after pressing + and - key in NOINI mode.
    Moreover when i go in Log 5 ,NOINITM mode 30% open the valve in both
    YEND1 and YEND2 once i press both + and - key.once i release button then
    actuator go to zero @t doesn't hold at all.If its abnormal what can i do.would you please advice me.
    if i press only either + or - button then actuator not move in YEND1 and YEND2
    mode.but when i press both + and - button simultaneously then it open actuator
    only 30% but not hold at all then when press hand button its display range
    message.
    will you please advice me its normal or abnormal?if abnormal then what can i do to fix this problem.
    Really i am facing a horrible condition for this positioner at my site and i am apologetically wish to get you kind advice please.
    Thanking You,
    Engr.Nizamul hoq.
    proprietor.
    United Mechatronics Engineers.
    Bangladesh.
    Email: united.mechatronics@@t
    Mobile : 0088-01814792505 and
    0088-01935675378(whatsapp)
    Skype: nizamul.hoq1

    • @nickthesaudibloggerchannel4467
      @nickthesaudibloggerchannel4467  4 роки тому

      first you need to check on your data sheet the exact preasure for you valve.if your preasure is correct kindly increase up to 5bar which is maximum.defends on your valve.also check ang verify on your data sheet for the open and closing time.you can see how much secon or minutes.
      second if you check and verify that there is no problem for your air supply and open and closing time limit.kindly check the packing make sure that is on hand tight..give me a feedback of you check that..thank you

    • @mr.nizamulhoq851
      @mr.nizamulhoq851 4 роки тому

      @@nickthesaudibloggerchannel4467 sir thanks for your valuable advice.actually same place if i put old existing positioner there then it working good. However air pressure is 4.5 KG there.can you please advice me which log i can change open/close time

    • @nickthesaudibloggerchannel4467
      @nickthesaudibloggerchannel4467  4 роки тому

      @@mr.nizamulhoq851 you can you loop calibrator/mA source you can apply 4-20mA make sure that you have 24vdc supply

    • @mr.nizamulhoq851
      @mr.nizamulhoq851 4 роки тому

      @@nickthesaudibloggerchannel4467 yes sir obviously i have inject 4ma there with 24 VDC power supply by loop calibrator.however interesting matter is existing old positioner work good same place

    • @nickthesaudibloggerchannel4467
      @nickthesaudibloggerchannel4467  4 роки тому

      @@mr.nizamulhoq851 so you mean you need to change the open and close position right?