Different types of lightning arrester | Spike Rod arrester Installation [हिन्दी]

Поділитися
Вставка
  • Опубліковано 4 лют 2025

КОМЕНТАРІ • 140

  • @munawarkhan1040
    @munawarkhan1040 4 роки тому +8

    Very well explain. Good one
    Thank you

  • @ashokchatur6712
    @ashokchatur6712 3 роки тому +2

    Thank you for sharing precious information.👍

  • @jamalakam
    @jamalakam 2 місяці тому

    Can we connect house earthing to lighting arrester.

  • @Satendra.maurya
    @Satendra.maurya Рік тому

    thank you so much dear ❣️
    भाई अपने तो सब दिखा दिया बस lightning ⚡ भी हो जाती तो सारा प्रोसेस ही कंप्लीट हो जाता।

  • @ratnadeepdhar4816
    @ratnadeepdhar4816 7 місяців тому +1

    Good but I was willing to purchase could not find the purchase link in your description. If possible kindly reply. Regards 🙏

  • @shubhampradhan9900
    @shubhampradhan9900 10 місяців тому +1

    Nice video please keep uploading new video

  • @jaherayo6978
    @jaherayo6978 4 роки тому +1

    Very good video on spike LA instn

  • @donalddsouza7342
    @donalddsouza7342 2 роки тому +1

    Sir ,please show me From where I can buy, link you shared doesn't work, you didn't mentioned gauge of wire , diameter and depth of puc ground pipe

  • @RajuJangde-uz7kx
    @RajuJangde-uz7kx Рік тому

    ❤❤ video beast hai thank you sir.

    • @SUNInnovative
      @SUNInnovative  Рік тому

      Please subscribe this channel we are publishing more related video soon.

  • @thirugnanam274
    @thirugnanam274 4 роки тому +3

    I have a doubt about fixing of spike ligtining arrestor directly mounted into base plate whether it is insulated base plate or normal base plate please clarify.

  • @hanumoluvenkateswararao3723
    @hanumoluvenkateswararao3723 4 роки тому +1

    Very good information.thanks

  • @sureshbandral9798
    @sureshbandral9798 4 роки тому +1

    very nice sir

  • @BlueSky-cy5nw
    @BlueSky-cy5nw 2 роки тому +1

    Lightning arrestor base plate needs to be insulated otherwise current is going to pass from lightning rod into the base plate and then into the building. What is the use of spending money on lightning arrestor and grounding if you are going to connect it to the building without an insulating base

  • @manpreetkumar2113
    @manpreetkumar2113 4 роки тому +2

    Thanks sir"ji 🥀

  • @ranachakraborty1487
    @ranachakraborty1487 4 роки тому +4

    Sir, which arrester would be better for the house ??
    Which company or size wire is best??

    • @Doraemon-75
      @Doraemon-75 4 роки тому

      Yes I also want to know (b t w tumi bengali..? 😁😁)

  • @differentak8574
    @differentak8574 4 роки тому +2

    Thank you sir

  • @ghayurabbas5422
    @ghayurabbas5422 4 роки тому

    Thanks sir, bht hi achy tariky se samjaya

  • @rajasekaranm7140
    @rajasekaranm7140 Рік тому

    Hi
    Where is the insulator between the base wall to copper rod
    Once the lightening happened how this will save the wall and house.
    The pls. Check the sufficient gage of copper wire or plate

  • @RadhikaDogra-c8f
    @RadhikaDogra-c8f Рік тому

    Sir plz no dedijiyee jha se main thundering lightening protection aresster purchase kr sku ghar ke liye ..m from ambala

  • @kartikvanand
    @kartikvanand 4 роки тому +1

    Do you have some vendors who could supply us top copper sphere with ni plating? pls suggest if any

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      www.suninnovative.in/product-page/lightening-arrestor-spike-rod-pure-copper

  • @aakardev4699
    @aakardev4699 3 роки тому

    Thank you for video. Please explain what material is used in earyh pipe. Also thickness of green wire.

  • @sachinbpathak
    @sachinbpathak Рік тому

    Nice explanation. I have a question. Why there is no insulator between base plate and wall . Thanks.

    • @SUNInnovative
      @SUNInnovative  Рік тому

      Yes its mandatory but there is two things
      1. Specially this site location is different then others because there is 0.1 % possibilities of lightening strike so no need to worry about it.
      2. Reason is if your cable is proper earth then lightening will pass through cable and settle to earth because earthing has lesser resistance then building structure so no need of insulator
      Note : not applicable to every location and building

  • @Devil_Rider_06.
    @Devil_Rider_06. 3 роки тому

    Kintne mm ka wire use kiyethe Aapne aur ishe mein gharka earthig vi connect kiye ho

    • @SUNInnovative
      @SUNInnovative  3 роки тому

      You can't connect house earthing with this, cable size 16mm

  • @pushpendrakumar5098
    @pushpendrakumar5098 4 роки тому +2

    Nice explained लेकिन आपने जो वायर यूज़ किया है क्या वो कॉपर रॉड का पूरा करंट कैरी कर सकता है । मुझे भारी डाउट है।

  • @tanzirulchy5621
    @tanzirulchy5621 3 роки тому

    thanks for a good Topic.Please Explain how much Coper Rod will be provide or explain Area coverage including quantity

  • @csingh3155
    @csingh3155 4 роки тому

    Excellent, lekin niche jo earthing me ek wire too arrester se ayi, aur dusri kis lie hai???
    Bro mere ghar mein full fitting earthing, 60 feet handpump mein kiye hai, kya es ko b us k sath joint kar sakte hai ja nahi, pls ????

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      You will need a separate earthing for LA

  • @karuneshkvaiswar612
    @karuneshkvaiswar612 3 місяці тому

    Ok
    Thank u very very much Ok
    Thank u very very much Ok
    Thank u very very much

  • @rogercabajes7575
    @rogercabajes7575 4 роки тому

    Were is your outlets in the Philippines

  • @ganeshchettri7355
    @ganeshchettri7355 3 роки тому +1

    Thankyou sir. can we find this ready arrester system in the market? if so what would be total installation cost for this rod system.

  • @nitishkumarroy7757
    @nitishkumarroy7757 3 роки тому +1

    What's the approximate cost of such type of installation.

  • @fulungsar
    @fulungsar 3 роки тому

    Sir can bare wire be used

  • @vinodingle5508
    @vinodingle5508 4 роки тому

    Wire ki jagah aluminium down conductor uesd kar shakte hai kya?

  • @monwar010
    @monwar010 3 роки тому

    Earth wire how much mm dia please

  • @Quotesandfactssociety
    @Quotesandfactssociety 3 роки тому

    How much area will be covered by this arrester?

  • @Darbar390
    @Darbar390 5 місяців тому

    भाई ये pvc पाइप कितने की है 2 की 3 की या 4 की।।।

  • @alokeghosh4389
    @alokeghosh4389 3 роки тому

    Please infrom the details of chemical used for earthing

  • @basantkumar6337
    @basantkumar6337 2 роки тому +1

    Pura kharcha kitna padta hai

  • @chetanrathod3388
    @chetanrathod3388 3 роки тому

    Kitne k.m cover krta he Spike arrester

  • @shankhaghosh3575
    @shankhaghosh3575 2 роки тому

    PURCHASE LINK?

  • @sourashis12
    @sourashis12 4 роки тому +1

    Sir, what is the required dimension of the connector wire?? Where can I get those road items??

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      www.suninnovative.in/product-page/lightening-arrestor-spike-rod-pure-copper

  • @jatinsingh181
    @jatinsingh181 4 роки тому +1

    Lightning arrester alkh se earthing krna pdta hai sir....house earthing ke sath chor sakta hai?

    • @SUNInnovative
      @SUNInnovative  4 роки тому +1

      Separate earthing and pipe is required

  • @AshuTrickZone
    @AshuTrickZone 3 роки тому +3

    Sir..which type of arrestor should I use for my house of 900sq.ft.?

  • @Sujayish
    @Sujayish 4 роки тому

    Its was very nice video. Very helpful. Could you please suggest us whether earthing strip can be used instead of wire ? if yes, what can be the size of the strip.

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      Strips are good rather than wire, if your area is dry and less chance for monsoon then wire is perfect.

  • @aminsayani6370
    @aminsayani6370 3 місяці тому

    Explosion type???

  • @PranoyRoy1991
    @PranoyRoy1991 3 роки тому

    Ek 1000sq foot ka ghar pr kitna lagana parega.

  • @prasadborkar1257
    @prasadborkar1257 3 роки тому

    Bhai description mein specifications kidar hai??

  • @rajeshthombare3264
    @rajeshthombare3264 3 роки тому

    मेरा 1200 sq फिट घर है और 5 kw सोलर roof टॉप है तो मै कौन सा lightning arrestor और इसके कौन कौन से पार्ट लगवाना चाहीये

  • @rampratapsingh3338
    @rampratapsingh3338 Рік тому

    Sir.yah.kaha.mil.jayega

  • @Ankvaastunidhaan
    @Ankvaastunidhaan 4 роки тому

    ye kya apne ap lightning strike KO khinchta hai?

  • @AbhishekSingh-bq1qx
    @AbhishekSingh-bq1qx 4 роки тому +1

    Do i need a lightning arrester if there is a jio tower 50m away from my house

    • @soulsearching3956
      @soulsearching3956 4 роки тому

      If the height of the jio tower is more than your house which should be 10 ft or more...then you dont need to install it...but you should protect your house from ur end whenever u get time n resources as u cannot depend on others ...in case the earthing of tower becomes out of order someday...
      The more height your building the more lighting strikes chances...

  • @sahebbera418
    @sahebbera418 2 роки тому

    Iska price kitna hain aur kaha milta hain?

  • @jawaharlalkaramchetti5675
    @jawaharlalkaramchetti5675 4 роки тому +2

    The bolt is lose in the hole, it should be tight fit to current flow. You don't have proper spanner to tighten. cutting plier is not for tightening.

  • @jay5446
    @jay5446 4 роки тому

    If lighting falls on distribution incoming line does it harm my solar plant?
    Or lightning falls on any wire of my house does it harm my solar system?

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      We provides DC and AC protection at distrubution box, so plant has protection om both side.
      Protection:
      MCB
      RCCB

    • @jay5446
      @jay5446 4 роки тому

      @@SUNInnovative what should be height of lightning arrresstor above solar panel top most positions?

  • @mhtenterprises6592
    @mhtenterprises6592 4 роки тому

    MHT enterprises (Aligarh) I am manufacture lighting arrester.. and earthing dealer..

  • @sadhuram1334
    @sadhuram1334 4 роки тому +2

    How many coast Sir ji .

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      www.suninnovative.in/product-page/lightening-arrestor-spike-rod-pure-copper

  • @chiranjitnaskar2751
    @chiranjitnaskar2751 3 роки тому

    Cost for 600 sq ft 3 Flore building????

  • @YouTube.24creator
    @YouTube.24creator 4 роки тому

    Ok

  • @DRGAUTAM123
    @DRGAUTAM123 7 місяців тому

    Road and Rod are two different things.

  • @tejendrasinghrahevar5447
    @tejendrasinghrahevar5447 4 роки тому +1

    can you please perform CLASS E COMMUTATION like you did for CLASS D?
    i wanted to know it....

  • @snehansupanda139
    @snehansupanda139 2 роки тому

    Price

  • @providentwelworthcityyelah5972
    @providentwelworthcityyelah5972 3 роки тому

    Earthing 2 wire connection why given

  • @bisakhabaitalik5873
    @bisakhabaitalik5873 3 роки тому

    Wir 10 mm.

  • @sachinkushwah1972
    @sachinkushwah1972 4 роки тому

    सर इसके हॉल मे कौन सा मटेरियल उपयोग मे होता है

  • @snehansupanda139
    @snehansupanda139 2 роки тому

    Price kitna he

  • @manojntm5118
    @manojntm5118 2 роки тому

    Kitne me milta hai

  • @subodhlook2204
    @subodhlook2204 2 роки тому

    Ye rod kaha milta h

  • @antramyadav7811
    @antramyadav7811 4 роки тому

    iska price kya hai

  • @kinshoo74
    @kinshoo74 3 роки тому

    Wrong installation as you have grouted the base directly on building without providing DMC insulator the lightening strike will directly enter building structure without following the earth wire path. Please correct your method

    • @SUNInnovative
      @SUNInnovative  3 роки тому

      Next time will contact you for installation 😀

  • @ffboy905
    @ffboy905 4 роки тому

    Wair kitana geg Ka Hona Chahiye

  • @jollythomas8677
    @jollythomas8677 4 роки тому

    Wire ka size tho aapne bathaya nahi. Our rod size please

    • @knownledgeadda6369
      @knownledgeadda6369 4 роки тому

      Minimum 35 sq mm copper cable.rod should be 17.2mm dia copper bonded rod .length 3 mtr.

  • @s.d.4351
    @s.d.4351 3 роки тому

    Spike road hai ki rod hai??

    • @SUNInnovative
      @SUNInnovative  3 роки тому

      Aapne jo suna vo. Sayad aap dekh nai sakte ki road nai laga rahe video me rod use Kiya he so use common sense sometimes

  • @diunclesony5265
    @diunclesony5265 4 роки тому

    Bhsi copor ka use q nhi kiya

  • @jollythomas8677
    @jollythomas8677 4 роки тому

    Wire ka size tho aapne bathaya nahi. Our rod ka size bhi. Please

  • @JugalKishor001
    @JugalKishor001 3 роки тому +2

    Unprofessional work

  • @bubundhar
    @bubundhar 3 роки тому +1

    Road nahi Rod

  • @ANANDYADAV-nw3gf
    @ANANDYADAV-nw3gf 4 роки тому

    Cost kitna ayyega bro plz tell.

    • @SUNInnovative
      @SUNInnovative  4 роки тому +2

      Around 3000

    • @Abhisheksingh_ID
      @Abhisheksingh_ID 3 роки тому

      @@SUNInnovative Sir, mujhe lightning arrester installation karwana hai purchase kahan se karoon

  • @sujaybala3510
    @sujaybala3510 3 роки тому

    How expensive for 1st floor house?

  • @profassor8491
    @profassor8491 9 місяців тому

    Main and major mistake

  • @GeetGeetArora
    @GeetGeetArora 4 роки тому

    koi technical baat nahi btayi, area covered n earth resistance ohms

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      30m area covered, resistance is less then 5 ohm.

    • @GeetGeetArora
      @GeetGeetArora 4 роки тому

      10ft ka copper arrester rod 30m radius cover karega?

  • @akshydomle5867
    @akshydomle5867 4 роки тому

    Area kitna meter cover kr lega

  • @AK-gi1ke
    @AK-gi1ke 6 місяців тому

    F

  • @antramyadav7811
    @antramyadav7811 4 роки тому

    mujhe chahiye

    • @SUNInnovative
      @SUNInnovative  4 роки тому

      www.suninnovative.in/product-page/lightening-arrestor-spike-rod-pure-copper

  • @mantukunar8210
    @mantukunar8210 4 роки тому

    Aapka Mobil no kya hai please dene ka kast karei

  • @Indianplayer
    @Indianplayer 4 роки тому

    bhai ye galat kr raha ha lightning arrester se wire connect nahi karna chaiye kyu ki wire ki limit hoti ha voltage aur amp. carry ki vo kam hoti ha

  • @rakeshgaur7896
    @rakeshgaur7896 4 роки тому

    टाइम पास ज्यादा है।

    • @rakeshgaur7896
      @rakeshgaur7896 4 роки тому

      @@shashikantmandloi6103 वीडियो काम का है लेकिन 14 मिनट का नहीं होना चाहिए था।

  • @Sujayish
    @Sujayish 4 роки тому +2

    Its was very nice video. Very helpful. Could you please suggest us whether earthing strip can be used instead of wire ? if yes, what can be the size of the strip.

    • @SUNInnovative
      @SUNInnovative  4 роки тому +1

      Depends on diameter of lightening coverage and earthing pit.

    • @knownledgeadda6369
      @knownledgeadda6369 4 роки тому

      It can be used but u should go for copper cable minimum size should be 35 sq mm. Wiring of strip is difficult and it can't be insulated so it is not safe.