What is ESE Lightning Arrester ? || How to Calculate Radius of Protection of a Lightning Arrester ?

Поділитися
Вставка
  • Опубліковано 11 чер 2022
  • What is ESE Lightning Arrester ? || How to Calculate Radius of Protection of a Lightning Arrester ? || working of Lightning Arrester || Knowledge of Lighting Arrester || How Lightning protect from lightning arrester ?
    #lightning #earthingnaturing #earthing #solarplant #solarsystem #structuredesign #LAdesign #lightningarrestercalculation #lighting_effect_template_video #lightninground #lightningblast #lightningonsolar
    Solar
    Safest
    Smarter
    Saur urja
    Biljli Kaise bachaye
    Solar se Bijli Kaise Bachaye
    Benefits of Installing solar
    Profitable solar
    Solar k Fayede
    Solar Lagane k Fayade
    MCB
    MCCB
    ACB
    AJB
    ACDB
    DCDB
    Lighting Arrester
    walkway
    cable Tray
    Solar Panel
    Solar Inverter
    Solar Cable
    AC Cable
    Follow me on -
    Telegram- t.me/+uVOzUWjDk0tiNTBl
    LinkedIn- / raman-kumar-666436141
    Facebook - / solarfacts-37057195372...
    solar structures
    Solar panel mounting structure
    Solar mounting structure
    acdb and dcdb for solar system
    acdb box price
    dcdb box for solar system
    dcdb box price
    long rail solar structure
    mini rail for solar panels
    mini rail solar structure
    solar mounting structures
    solar panel structure
    solar structure
    solar structure types
    types of mounting structures for solar panels
    types of solar mounting structure
    types of solar structure
    mounting structure for solar panels
    mono rail solar structure
    solar acdb box
    solar acdb dcdb box
    solar dcdb box
    solar mini rail
    standing seam solar structure
    tilted solar structure
    acdb box for solar
    dcdb box for solar
    Video link -
    1. How solar zero export works.- lnkd.in/evPgfuj2
    2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
    3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
    4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
    5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
    6. How to check Current Transformers? - lnkd.in/eT5gc99e
    7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
    8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
    9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
    10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
    11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
    12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
    13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
    14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
    15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
    16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
    17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
    • Solar Power Plant Shad...
    19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
    20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
    21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
    22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
    23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
    24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
    25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
    26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
    27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
    28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
    29. Comparison between string inverters vs micro inverter // Benefits of micro inverter. -- • Comparison between str...
    For more information contact us 😊.
    Name - Raman Kumar
    Contact No- 9871073342

КОМЕНТАРІ • 83

  • @sjain218
    @sjain218 4 місяці тому +1

    Excellent illustration/explanation on LA

  • @sachinjoshitechnojoshi1804
    @sachinjoshitechnojoshi1804 Рік тому +2

    Good knowledge sir

  • @anildeore3184
    @anildeore3184 6 місяців тому

    Thank you sir for wonderful information

  • @md.mirajalalim777
    @md.mirajalalim777 4 місяці тому

    Thank you very much... I was looking for this video. Very informative and the concept is clear .

  • @ehteshamhaider6196
    @ehteshamhaider6196 2 роки тому +1

    Thank you sir for sharing such a wonderful information. ❤

  • @mrcricket1640
    @mrcricket1640 Рік тому +1

    Excellent sir buhat achi video hai

  • @AKELECTRICPOWER
    @AKELECTRICPOWER 2 роки тому +1

    Informative , Great Work

  • @kamleshmaheriya2366
    @kamleshmaheriya2366 Рік тому +1

    Sir that is a very very very special video for me each and every information very neatly mentioned.
    Thanks you sir

  • @rajaanzar6871
    @rajaanzar6871 Рік тому +2

    Thanks a lot for explaining .

  • @Amazingsolar7753
    @Amazingsolar7753 2 роки тому +1

    Very informative video

  • @prakashshaw7509
    @prakashshaw7509 10 місяців тому +1

    Your handwriting is amazing

  • @siddhantsingh4798
    @siddhantsingh4798 2 роки тому +1

    This video is very learning 😊

  • @nimeshmandal7606
    @nimeshmandal7606 2 роки тому +1

    Great explanation sir👍🏻

  • @zeeshanalikhan5167
    @zeeshanalikhan5167 2 роки тому +1

    Very well information with good explanation...👍

  • @RaviKumar-rp9qg
    @RaviKumar-rp9qg 2 роки тому +1

    Very nice video

  • @rahuldubey1005
    @rahuldubey1005 2 роки тому +1

    Good Explain Sir..

  • @ratnadeepdhar4816
    @ratnadeepdhar4816 29 днів тому

    Very elaborately explained can you suggest from where to buy lightening arrest kindly reply. Regards 🙏

  • @ashokkumarbaranwal8198
    @ashokkumarbaranwal8198 Рік тому +1

    Very much informative, कृपया लेवल 1 लेवल 2 लेवल.3 लेवल 4 को समझाइये यह क्या होता है।

    • @solarfacts4242
      @solarfacts4242  11 місяців тому

      That is basically to protection levels
      Upto what area you want to protect from the LA

  • @anilpal9321
    @anilpal9321 11 місяців тому +1

    Good tools

  • @mohdfaizuddin2710
    @mohdfaizuddin2710 Рік тому +1

    most thank you

  • @husnainyasir9119
    @husnainyasir9119 5 місяців тому

    ❤from Pakistan

  • @surajgusain7042
    @surajgusain7042 2 роки тому +2

    Very Informative video 👍👍👍👍👍👍👌👌👌👌👌👏👏👏

  • @shahidqadri4340
    @shahidqadri4340 Рік тому

    I am watching your engineering videos, which are really very good and full of deep research and informative. 👍❤️
    My question is,
    What is difference in between zero export to power device and built-in power limiter in on grid solar inverters? Which one we should avail for safety and cost effective.
    Thx.

    • @solarfacts4242
      @solarfacts4242  Рік тому

      Thank you and I will make one video on your topic

  • @AnkitVerma-cj9cm
    @AnkitVerma-cj9cm 4 місяці тому

    Very informative vedio.
    Pls tell what should be the value of Earth Resistance for the down conductor?

  • @PakDigitalCountry
    @PakDigitalCountry 5 місяців тому

    Great thanks
    Pl advise dgpv device and analysers with diagram

  • @akshaynegi7018
    @akshaynegi7018 6 місяців тому

    Hello sir can you please tell us what is the minimum height of a building required for LA protection

  • @user-uq4su4xh9o
    @user-uq4su4xh9o 4 місяці тому

    Bhai kisi bi cheez par agar solar lagana ho to calculation running ampere k hisaab se karty hai ya starting, bhai zaroor btana❤❤❤

  • @gourangasasmal8815
    @gourangasasmal8815 Рік тому +1

    Nice video, please upload for high raise building lps system which is use steel welding,

  • @debjitdas2745
    @debjitdas2745 2 роки тому +1

    Nicely explained. In 12:30 Can you explain when to select level-1, 2 or 3 during our design stage? I mean, does the 'level' indicates location where we install our LA?

    • @solarfacts4242
      @solarfacts4242  2 роки тому +1

      No basically Lightning Arrester have all these four levels
      Basically level defines the length and percentage of protection

  • @shrikantvaze7258
    @shrikantvaze7258 5 місяців тому

    Please sir, explain Rolling sphare method Lighting arrester

  • @manishhchincholkar9283
    @manishhchincholkar9283 2 роки тому +1

    Hi,
    In regular installations, we are using conventional lightening arrester ( instead of ese type )...
    Will it protect solar system from lightening???
    Further, switching off solar inverter when there are chances of lightening, can safeguard solar system..
    Kindly advice

    • @solarfacts4242
      @solarfacts4242  2 роки тому

      Yes conventional Lightening arrester will also work but calculation and design should be proper

  • @TechnoEveryday
    @TechnoEveryday 10 місяців тому +1

    Can we install radio link device on the pole?

  • @earthingsolution255
    @earthingsolution255 10 місяців тому +1

    Hlo sir,
    Now a days we are facing lot of customer and contractor saying that ESE is not applicable in India.
    Kindly advice.

    • @solarfacts4242
      @solarfacts4242  10 місяців тому

      Sir you are correct there are lots of Agencies who is saying we should only install conventional type lightning Arrester not ESE type because ESE type attract the lightning and after installing ESE type it is dangerous to invite lightning that’s why they suggest conventional type

  • @ellyoriko
    @ellyoriko 2 роки тому +2

    Maan. I am subcribed to your youtube but I can’t get the most out of it because of the language barrier. Kindly see a way of assisting us.

    • @solarfacts4242
      @solarfacts4242  2 роки тому

      Sorry Sir
      Actually very soon I am coming with my website that will help you.
      Sorry

  • @aliazam8842
    @aliazam8842 Рік тому +1

    How to select cable for this system?

    • @solarfacts4242
      @solarfacts4242  11 місяців тому

      Already there is video in my channel
      Please go through

  • @saurabhmeshram972
    @saurabhmeshram972 2 роки тому +1

    Can you assist in 1mw project under kusum component A yojna...???

  • @user-wb2ms1zg7o
    @user-wb2ms1zg7o 11 місяців тому +1

    Nice to see your explanation. But center of the Rp (Radius of protection) is not mentioned. Without this how can we see the area is protected?

  • @AMITKUMAR-pt9bk
    @AMITKUMAR-pt9bk Рік тому +1

    For metallic structure upto height of 30meter we should go for LA

  • @skasad8456
    @skasad8456 Рік тому

    Can you please tell me how to determine the number of down conductor

  • @karthickkumar2567
    @karthickkumar2567 Рік тому +1

    In that formula del L = V x del t, v means what plese explain that

  • @rushikeshpulate5120
    @rushikeshpulate5120 Рік тому +1

    How to select level of protection ?

    • @solarfacts4242
      @solarfacts4242  9 місяців тому

      That data you can get from LA manufacturer

  • @mridulkundu6907
    @mridulkundu6907 Рік тому +1

    আপনি কি আমাদের ক্লাস নিচ্ছেন

  • @sudampatra5608
    @sudampatra5608 Рік тому

    How to choose level of protection

    • @solarfacts4242
      @solarfacts4242  Рік тому

      As per your requirement or according to lighting prone area

  • @mangeshiyer4711
    @mangeshiyer4711 Рік тому +1

    Sicr

  • @ikpalian4413
    @ikpalian4413 11 місяців тому +1

    No English 😢😢

  • @user-we8fo6fe6v
    @user-we8fo6fe6v 8 днів тому

    Keep mouth away