TDK LAMBDA VEGA 650W modular power supply repair reconfigure teardown

Поділитися
Вставка
  • Опубліковано 26 жов 2024

КОМЕНТАРІ • 14

  • @FJL4215
    @FJL4215 Рік тому +3

    Looks like the output modules use saturable reactors/magamps to regulate the output. Neat!

  • @kresimirpecar4925
    @kresimirpecar4925 2 роки тому +2

    Did you consider to calculate loads ? You have this power resistor and a fan working... That must be at least 30W

    • @TeardownOZ2CPU
      @TeardownOZ2CPU  2 роки тому +1

      good and valid point : the 12R load resistor is located +6V and -6V between two individual isolated 6V supplies, that means they will most likely be paralleled or series connected when the connector is put into the server it was ment for, in my setup, there is 0V over that resistor = cold.
      The fan is only a few watts :-) the rest is the methode : to drive the transformator at full PWM

    • @kresimirpecar4925
      @kresimirpecar4925 2 роки тому +1

      Yea... Quite a power loss, but then again, i don't think that this was a concern to the people running this PSU haha

    • @TeardownOZ2CPU
      @TeardownOZ2CPU  2 роки тому

      @@kresimirpecar4925 exactly.. a larger server or stuff like that, powered all day long :-)

  • @transparentlab8318
    @transparentlab8318 11 місяців тому +1

    When it goes in load, MOSFET are blown what can I do in this situation ?

    • @TeardownOZ2CPU
      @TeardownOZ2CPU  11 місяців тому +1

      Current feedback or current regulation cycle by cycle not working

    • @transparentlab8318
      @transparentlab8318 11 місяців тому +1

      @@TeardownOZ2CPU Is it repairable?

    • @TeardownOZ2CPU
      @TeardownOZ2CPU  11 місяців тому +1

      Yes, easy with schematic, takes a bit later longer if no sch

    • @transparentlab8318
      @transparentlab8318 11 місяців тому

      @@TeardownOZ2CPU May I consulte with you if you don't have any problem?

  • @Sine1040
    @Sine1040 2 роки тому +1

    I have my doubts about the accuracy of that power meter, that standby power use can't be THAT bad ...

    • @TeardownOZ2CPU
      @TeardownOZ2CPU  2 роки тому +1

      i am so sorry, but it does actually sample current and voltage at correct timing and perform correct power usage, The Peacefair PZEM-021 energy meter, uses Renergy RN8208G the energy meter IC, it is approved for billing too, so far i was not able to find anything else that is more accurate, the High idle usage is ude to the methode this converter use, a full power fixed primary switcher, yes it will have a very high idle power usage, BUT this supply is not designed for light load, or variable load. most likely used in servers, where it is loaded 50-80% all the time

  • @iwankustiawan4791
    @iwankustiawan4791 2 роки тому

    I have a TDK-Lamda HWS1500-36, have a complaint when the electricity is entered, the voltage comes out 36v, but after 1 minute the voltage goes out and the indicator light turns off, but the fan is still on, what should be fixed?

    • @TeardownOZ2CPU
      @TeardownOZ2CPU  2 роки тому +1

      measure mains power usage, and try load it, also use a scope, see the 36V out, load it 10% and 50% and see what happens, voltage ans scope and input power, this way you know where to fix