Extractive Distillation of Ethanol and Benzene using p-Xylene in DWSIM

Поділитися
Вставка
  • Опубліковано 5 лис 2024

КОМЕНТАРІ • 31

  • @muhammadyasir9056
    @muhammadyasir9056 28 днів тому

    Simply superb ❤, please keep it up as it's helping many engineering students as well as working professionals.
    Thanks for your contribution dude ❤

  • @majedaljaber134
    @majedaljaber134 3 роки тому +4

    I appreciate your spent effort in making such fabulous videos!
    Keep on, please!
    Wish you all the best academically and professionally!

    • @eduXinsight
      @eduXinsight  3 роки тому +1

      Thank you so much for the appreciation.

  • @jay39157
    @jay39157 3 роки тому

    I am very much impressed by the way speedily you perform simulation.We are learning many things from you.
    Keep up good work continue
    Thanks

  • @ВладимирЕгоров-и2л
    @ВладимирЕгоров-и2л 11 місяців тому +2

    Thanks for your hard work!
    I have a problem.
    My list of CAPE-OPEN Unit Operation is empty. how to add?
    thank you in advance!

  • @nidhisharma6967
    @nidhisharma6967 2 роки тому +1

    Thanks a lot for this video sir. Really very helpful. Want to learn more and more from here, keep up the good work. Thanks a lot again😇

  • @ImperatoreTeo
    @ImperatoreTeo 2 роки тому

    I have some questions:
    1) which are the difference between complex coloum and azeotropic distillation? min 11:00
    2) why you set total liquid reboiler on the second coloum? It shouldn't partial liquid?
    3) My ethanol stream has only 72% of ethanol while you have 96%?

  • @-_HansMartuaPardede
    @-_HansMartuaPardede 2 роки тому +1

    Sir, I Drag Cape-Open Unit operation and I click OK but there is something happend, the flash unit of column distilation is nothing, so what is solution for this Problem?

  • @salisusani23
    @salisusani23 2 роки тому

    QUESTION!
    Hello Muhammad, Thank You for this educative videos.
    I TRIES THIS EXAMPLE BUT I KEEP GETTING NaN error in the Solvent Stream connected to the Mixer.
    Please help.

  • @juancq8689
    @juancq8689 3 роки тому +2

    I have a question: In the flash distillation unit, is correct that the ethanol is in the top of the column(consider that the boiling point of Benzene is 78 C and Ethanol is 80 C) ?

    • @eduXinsight
      @eduXinsight  3 роки тому +4

      Hi Juan, Thanks for your interesting question. Yes, it is true in a binary mixture of ethanol and benzene that ethanol should be the bottom product. But the addition of p-xylene
      as a heavy entrainer to enhance the relative volatility of ethanol over benzene. Hence, ethanol is separated from the distillate of the first extractive distillation column while the bottom stream containing benzene and p-xylene is sent to an entrainer recovery column to obtain benzene from the top of the column. For details please read the following article: pubs.acs.org/doi/abs/10.1021/acs.iecr.9b03095
      I hope your doubt is cleared.

  • @thisisbismay5681
    @thisisbismay5681 3 роки тому +1

    Very informative

  • @srivathsa1848
    @srivathsa1848 3 роки тому

    Can you please do a simulation video on pressure swing distillation.

  • @chisomchuba9672
    @chisomchuba9672 3 роки тому +1

    I followed all your instructions except the specifications in each column, I specified top and bottom mole fraction instead but got an error.

    • @eduXinsight
      @eduXinsight  3 роки тому

      Can you share with me the error details?

  • @affanbhaijaan65
    @affanbhaijaan65 2 роки тому +1

    Sir what should we do if we don't have number of trays and reflux data given in the question

    • @eduXinsight
      @eduXinsight  2 роки тому +1

      First do shortcut distillation to find out the approximate number of plates and reflux.

  • @AroojFatima-zz2yr
    @AroojFatima-zz2yr 3 роки тому

    You are genius 💪

  • @danielnm6767
    @danielnm6767 2 роки тому +1

    Good day Sir, I've followed all the steps you did in the video, but when it comes to the ChemSep column, I am not able to see the thermodynamics window, and as a result, my simulation gives me an error. Do you know how can I be able to activate such window?

    • @eduXinsight
      @eduXinsight  2 роки тому

      well, I am not sure about it. because I did this simulation in the previous version of DWSIM. I will suggest you upgrade to the latest version of DWSIM and then see whether it solve the problem or not?

    • @danielnm6767
      @danielnm6767 2 роки тому

      Unfortunately I've updated the software since the 6.4 version and the problem remains the same. Thanks for the reply.

    • @albertoaguilar9773
      @albertoaguilar9773 2 роки тому

      I'm having exactly the same issue, the thermodynamics window won't appear, only reactions.

    • @bharatiyainnovator3185
      @bharatiyainnovator3185 4 місяці тому +1

      I also have the same issue

    • @bharatiyainnovator3185
      @bharatiyainnovator3185 4 місяці тому

      ​@@albertoaguilar9773hey did you get the solution to it ?

  • @danear2
    @danear2 3 роки тому

    Hello my friend and thanks for the video
    How can I contact you..?

  • @asmaabdelhamied9012
    @asmaabdelhamied9012 4 місяці тому

    How add cape-open to dwsim

  • @abhinavgupta1136
    @abhinavgupta1136 3 роки тому

    I can't get that research paper can you please send me the pdf file or link to download the paper.

    • @abhinavgupta1136
      @abhinavgupta1136 3 роки тому

      Please reply I am working on this project. So I need that research paper.

  • @rider-bi7lv
    @rider-bi7lv 3 роки тому

    How can i contact you
    i need help in a project