Garage Wiring Code Violations

Поділитися
Вставка
  • Опубліковано 1 жов 2024

КОМЕНТАРІ • 84

  • @johnmazzocchi7116
    @johnmazzocchi7116 11 місяців тому

    Hey Ron!! Hope you had a great trip to Dallas! Nice work with the EMtT!! Why didn’t you use PVC?? lol
    Just kidding. Have a good one!! Jets and Giants tomorrow!! Enjoy🍻🍻⚡️⚡️🔌💡🏈🏈

  • @stevencole7331
    @stevencole7331 10 місяців тому +2

    Curious that I have seen exposed Romex in other videos of yours as acceptable . Mostly in basements with electrical panels . Would it not be acceptable on the ceiling of this garage ? . Also when you think about it running Romex in attics you would think walking on that Romex while working in the attic subjects it to physical damage . It's such a vague description on what constitutes physical damage . Now I run conduit for all my exposed work . Nice job .

  • @philiplarson8228
    @philiplarson8228 11 місяців тому +5

    Ron, I enjoy your videos and I feel for you too. I’m regionally worked in the south for 45 years and somehow I got tricked by my wife move to Midwest. I have never encountered a smorgasbord of the wiring technique and how it ever got passed by inspection. I’m still scratching my head, there’s a NEC way and then what you’re doing correcting, unsafe, wiring techniques. I hope the homeowner understands that if something happens to the home and the fire marshal reports this the insurance will not cover their home. It’s Very important to have a license electrician/contractor for the homeowner safety. Keep doing your great stewardship videos.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +3

      Brother you aren’t kidding! This house under contract so these violations were brought up in an inspection report. The buyers hire a home inspector then the owner pays to have the work repaired/ replaced/ and/ or removed. I love what I do! I’m happy you enjoy the channel!!

    • @1D10CRACY
      @1D10CRACY 11 місяців тому +1

      Just to comment on the insurance. My home caught fire due to faulty wiring that was not up to code. Not only will the fire department investigate the fire and determine the cause, the insurance will send their own team in to do their own investigation. The fire department blamed a faulty chimney, despite telling them there was not a fire in the fire place. The Insurance found bad wiring that was also not up to code. They covered the claim and as per them, other than my word they had no idea if I had done the wiring or a previous owner. The previous owner did tell me they hired a licensed electrician to update the wiring. Obviously it's always better safe than sorry and the wiring needs to be cone correctly, but I thought I'd share this to let people know how the claim sort of works.

  • @linehandibew6205
    @linehandibew6205 11 місяців тому +3

    Great video. Quick question. The romex from the ceiling box back to the panel is still exposed. Is t that still an issue?

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +2

      I think it’s out of the way and not an issue. Do you? I was thinking a short piece of framing lumber (like a 2x4) could cover that up pretty easily.

    • @donmclean1220
      @donmclean1220 8 місяців тому

      @@electricianron_New_JerseyI agree, a little wood could be used to cover the Romex in the ceiling corner.

  • @tolydukhovny682
    @tolydukhovny682 11 місяців тому +1

    this is a nice content.
    you are shaking your selfie stick too much. i am getting a vertigo.

  • @ed6837
    @ed6837 3 місяці тому

    I would much rather use EMT than PVC. Wires pull easier in EMT. PVC gets crooked and wonky unless you use a lot of straps. EMT 3' off the box and every 10' (I usually did 8') and you're done. Nice little job Ron.
    That old wiring was better than a lot of DIY stuff. At least the guy grounded it.
    If you really want to cringe, go to upstate NY or Vermont. You have never seen sketchy until you go there. I had a Masters in VT before I retired. Back then you didn't need to have a license to wire a house. Don't know if that has changed.

  • @ThomasWalker-m2y
    @ThomasWalker-m2y 11 місяців тому

    Nice work , but ALLWAYS put a plug in over blank plates. ALLWAYS!!!!
    AND NO'S I DON'T KNOWS WHAT I'M TALKING ABOUTS

  • @somethingelsehere8089
    @somethingelsehere8089 11 місяців тому +1

    I have a hard time swallowing that the risk of damage to the cable on the ceiling outweighed introducing all those additional joints in a feed to a dryer. That said, the wire running from the light to the side of the cabinet was pretty cringey.

  • @MrKen59
    @MrKen59 10 місяців тому

    What about MMC instead of Conduit? Thanks and have a great day.

  • @rodolfovesga979
    @rodolfovesga979 Місяць тому

    Cool video Ron I like that use of EMT looks lot better

  • @brianh2324
    @brianh2324 2 місяці тому

    Hello, I'm new to your channel. I just finished building a garage and I'm trying to get a real answer to what wire I should use from house box to sub panel in garage. I have been told 6/3 and others have different size. House is 100 amp, sub will be 50 amp. Other than lights,openers and a small air compressor I have a 125 welder that plugs in 110. Hope you can help.. thanks

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  2 місяці тому

      If it were I’d ask for PVC conduit buried minimum 18” deep with #6 AWG copper THHN/ THWN 4-wire.

  • @davidmarquardt9034
    @davidmarquardt9034 3 місяці тому

    I've always thought that EMT was used indoors, whereas PVC is used outdoors and underground feeds, since it can be made watertight and does not rust and collapse underground. Of course unlike EMT its not self-bonding, being non conductive, so you have to remember to pull a green wire to bond the system.

  • @panama-sx2oh
    @panama-sx2oh 10 місяців тому

    Another great video. I SEE YOU A MILWAUKEE MAN I LOVE MY DEWALT. I HAVE THAT KLEIN TESTER LOVE THEM BOTH. ARE YOU A ONE MAN COMPANY OR DO YOU HAVE OTHER WORKERS. GREAT VIDEO KEEP THEM COMING

  • @cdfornal
    @cdfornal 11 місяців тому

    What’s the green screw for ? Isn’t EMT a grounding conductor?

  • @ClippyC
    @ClippyC 11 місяців тому +1

    too funny - people complain about using metal or pvc? lol Hope you have a wonderful day.

  • @Lanceb131
    @Lanceb131 11 місяців тому

    What is the fishtape that broke on you again. I'm thinking of getting 1 & want 2 avoid it. TIA. Great work! IMO & IME PVC should never be used. It just turns into a mess! We had some put in at my work & like 2 years after that the clips started braking & everything, was just a HUGE mess & I volunteer for a local no kill pet rescue in my area that is a 501 C 3 non-profit so that was a HUGE & expensive problem!

  • @tray8411
    @tray8411 4 місяці тому

    Great work!!! I cant believe the person that lived there before couldn't reach out to someone that at least has some knowledge of Elec work... I have to DIY BC im rural but I always re check my work with a qualified Electritian through FaceTime

  • @anthonyelectric6045
    @anthonyelectric6045 10 місяців тому

    Ron the only problem I have in the video was the Islanders jersey in the background 😂 LGRs. Nice fix bro 👍

  • @aaron74
    @aaron74 11 місяців тому

    Nice cleanup there. WTF is that really old 10/2 (or 10/3) romex with the fiber sheath going to the dryer receptacle?! Did you deal with that end of it? That is so strange, someone recently installed that old cable? Must be recycled cable obviously. PVC or EMT? I vote PVC for outside residential, and EMT for everything inside that doesn't need liquid tightness. EMT just has the "workmanlike" aesthetic in a dry environment. Though I think EMT is suitable for wet environments too, I think it comes in aluminum and stainless.

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp 11 місяців тому

    Old school and alwsys used EMT in houses. Too often I would not run any PVC and cement was bad. Ran EMT in rear of my basement to feed washer & dryer & new circuits and to the garage. Only wish that I would have ran EMT or ENT to second floor bedroom TV'S 40 years ago. Ran RG 5 cable and a few years ago when cable company installed new cable boxes tried to tell me that I ran the wrong cable. Told the cable clowns that far superior RG6 cable was not out when I ran that cable.

  • @outlet6989
    @outlet6989 11 місяців тому +1

    Hi Ron. When I wired my two-car garage, I ran all exposed cables through metal conduit. I did this in case a blade or other sharp object got loose or I became DIY frustrated and threw something. All wiring is 12 gauge, and all outlets are 20amp rated. For four or fewer outlets, I wired them to a separate breaker also rated for 20amps. I realize this is overkill, but it is still cheaper than hiring an electrician, and it looks so good.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +3

      Nothing wrong with more than what you need. 20A x 120V = 2400 watts. Plus (4) circuits like that! 4 x 2400 = 9600 watts. Dude, you can run a lot of stuff with that much capacity.

    • @outlet6989
      @outlet6989 11 місяців тому +1

      Hi Ron. Thank you for your nice reply. I forgot to add why I strive to do the best electrical work. My next-door neighbor is a retired master electrician. He knows I always strive to do the best and my time, effort, and cost don't concern me. Thanks again and have a nice and safe day.🔌@@electricianron_New_Jersey

  • @GlenMacNeil
    @GlenMacNeil 8 місяців тому

    Did this installation require an inspection?

  • @rb8049
    @rb8049 11 місяців тому

    I’m installing wiremold. It’s and OK way.

  • @curtw8827
    @curtw8827 11 місяців тому +1

    Nice job. As a consulting/design engineer I always required two hole straps and did not allow screw fittings, but that's just me on commercial, educational, and industrial projects.

    • @edisont.picard4112
      @edisont.picard4112 9 місяців тому +1

      That's because, as an engineer, you don't know what is practical and what is not. In the field, we often just ignore unrealistic pie-in-the-sky engineering specs.

    • @curtw8827
      @curtw8827 9 місяців тому

      @@edisont.picard4112 after 25 years of experience inspecting work, there are too many loose set screw couplings, conduits coming disconnected, fasteners pulling out, It's simple, follow the specs or I don't sign your pay application, and you get to do the work over. Specifications my client paid me to write can exceed Code minimums. Remember, the Code book is not a design guide, but minimum standards.

  • @StephenCunningham1
    @StephenCunningham1 3 місяці тому

    This makes no sense. There is still exposed romex

  • @bigdaddy4975
    @bigdaddy4975 11 місяців тому

    Look up sog electricians knife you will love it.

  • @bigdaddy4975
    @bigdaddy4975 11 місяців тому

    You will carry this knife everywhere you go

  • @edwardleonard7538
    @edwardleonard7538 11 місяців тому +1

    i thought you could not run two seperate voltages in the same conduit..?

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +2

      They're both in the same distribution panel too!

    • @Sparky-ww5re
      @Sparky-ww5re 11 місяців тому +1

      You're not allowed to run low volt wiring meaning telecommunications cables, doorbell wiring, in the same raceway or outlet box as line voltage unless the box has a divider to separate the low and line volt wiring. You're also not permitted to install service conductors in the same raceway as feeders or branch circuit wiring, but feeders and branch circuits can be in the same raceway. Service conductors are UNFUSED, and a short between a service conductor and a feeder or branch circuit conductor leaves a circuit with no overload or short circuit protection.

    • @pawelelektryk2985
      @pawelelektryk2985 11 місяців тому +1

      I believe it's voltage to ground.so the *240v* dryer circuit is still only 120v to ground.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +1

      @@jrbay1 it’s got to have the same voltage rating on the insulation.

  • @ashleysipe745
    @ashleysipe745 11 місяців тому

    I like the 480 single phase jumpers!

  • @MB-ir8xf
    @MB-ir8xf 11 місяців тому

    Gee's Ron! you get a pass because you do not work with EMT, but you could have done better. 10 degree offsets for the junction boxes needed and 30 degree offset's for those corners. well, I give you credit for using EMT.

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +2

      You can do whatever you want on your jobs. Sure, I could’ve done a 90 and a 3-4” offset at 30 degrees but I didn’t see it like that while I was doing it. I’m fine with my install.

  • @gabimen7460
    @gabimen7460 11 місяців тому +1

    You sell your t shirts ?

  • @johnmazzocchi7116
    @johnmazzocchi7116 11 місяців тому

    By the way, that rackatier is the best just picked one up

  • @Bob.W.
    @Bob.W. 11 місяців тому

    Lightning strike Tuesday morning took out all my new shed wiring and a fair bit in the house. Mini-split died last night, right after the tech thought it was OK. Metal covers on jct boxes blew off. All GFIs gone, plus 5 breakers. Hope the wires in the wall are OK. Great fun. Thx.

  • @TKomoski
    @TKomoski 11 місяців тому

    Ron would code let you use BX cable on the runs that you where making? Cheers

  • @nelsoncaraballo9446
    @nelsoncaraballo9446 11 місяців тому

    I was surveying my brother's garage. Only one receptacle. NOT GFCI. While following lines to panel I found a neatly roller up line of ROMEX rolled up in the rafters with zipties, LIVE, going nowhere?! Will be doing some updates for him.

  • @robertb8899
    @robertb8899 11 місяців тому

    I enjoy your videos . i would have piped back to panel and get rid of exposed romex

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +1

      I’ll give the buyers your contact info.

    • @robertb8899
      @robertb8899 11 місяців тому

      Good one . Just trying to help out channel by commenting . I thought it helps with the algorithm . I like your set up and enjoy your Real world videos .

  • @macdawg6403
    @macdawg6403 11 місяців тому

    Nice Vid!

  • @christobaldaetz6062
    @christobaldaetz6062 11 місяців тому

    Nice work like usual!

  • @davidfeldman7001
    @davidfeldman7001 11 місяців тому

    Hi Ron, love watching your videos. I have a question. You left the two Romex cables running from the electric panel to the first junction box. They were tucked into the corner where the wall meets the ceiling. Is this OK to have exposed Romex this way? I always thought you could not have exposed Romex more than just several inches.

    • @adassociates8235
      @adassociates8235 11 місяців тому

      He forgot the code😊😊😊😊

    • @adammorgan9304
      @adammorgan9304 11 місяців тому

      There is some ambiguity as far as the “protection from physical damage. It’s pretty out of the way in the corner but sleeving the whole cable might have been better

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +1

      It's really judgement call. None of this is being inspected but IMO it's no longer subject to physical damage.

    • @JasonEDragon
      @JasonEDragon 11 місяців тому

      @@electricianron_New_Jersey I agree with the changes to the light. And I'm sure that you did what you had to do to those 2 circuits to meet code in your area. And you did it in a cost-effective manner that the realtor likely prefers. Still, it is videos like these that make me grateful that my service panels (and other utilities) are in my unfinished basement where things can be more easily upgraded properly. Adding 2 splices to each wire just goes against the grain for me for the limited practical safety improvement.

    • @TomCee53
      @TomCee53 11 місяців тому

      I thought you could go one size smaller for the ground? Has that changed?

  • @Deafjustin
    @Deafjustin 11 місяців тому

    Good job I love watch your video when you work with electrical inside of house during winter time !

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому

      It's 80-something degrees here every day.

    • @Deafjustin
      @Deafjustin 11 місяців тому

      @@electricianron_New_Jersey Vancouver will be very cold in November and December under 0 temperatures

  • @kevinstrauss8020
    @kevinstrauss8020 11 місяців тому

    The thirty amp line to the dryer would normally be #10 copper, but because there are 5 current carrying conductor, you need to upsize to #8 copper.

  • @chuckquinn8026
    @chuckquinn8026 11 місяців тому

    Hey Ron, stupid question: Can any non-contact tester work on a DC circuit/wiring, or just AC?

    • @electricianron_New_Jersey
      @electricianron_New_Jersey  11 місяців тому +1

      I'm pretty sure this volt-tick by Klein does do DC current. I'm sure I've troubleshooted it with the wafer LED's.

    • @chuckquinn8026
      @chuckquinn8026 11 місяців тому +1

      @@electricianron_New_JerseyI checked out the Milwaukee powered fish tape after seeing you using it and also saw all the crappy reviews on it…Milwaukee blew this one unfortunately 😢