    @dane1976 Рік тому +8

    All the time this takes and supplies needed (the cost exceeds a replacement) you convinced me throw out my broken one. Thanks! BTW, you can go faster with those bursts. Not necessarily to go that slow.

    • @michaelprosperity3420
      @michaelprosperity3420 Рік тому +2

      You can buy the refrigerant for about $89 bucks and the piercing valve for about $10. The refrigerant he has that comes with the gauge is about $190. The $89 refrigerant doesn't have a gauge. My take on this is if I'm going to spend $190 for the refrigerant I'll get a leak detector, piercing valve, a really good gauge set on Amazon and then get the $89 can and I'll have the equipment to service other things around my house. My refrigerant is the R410-a

    • @nudracodad738
      @nudracodad738 Рік тому

      @@michaelprosperity3420 I strongly believe that R410-a is could be easily replaced by R-134A

    • @joshledford8921
      @joshledford8921 2 місяці тому

      My dehumidifier cost over $500.00 This is well worth it in my opinion.

    • @nickdangelo2591
      @nickdangelo2591 Місяць тому

      @@nudracodad738 can i really use 134a in a 410a system ?

  • @BENZ007
    @BENZ007 Рік тому +2

    Thanks for these 2 videos, this one looked very similar to mine and now it works great. Was just low on refrigerant. I got the piercing valve from Walmart.

    • @supjay3945
      @supjay3945 6 місяців тому

      Whats the kit called? Thx

    • @BENZ007
      @BENZ007 6 місяців тому +1

      @@supjay3945 before you try it, mine lasted about 4 weeks and died again, likely leaked out. So I bought a new dehumidifier. It's just an a/c tap line. Ordered it from Walmart. Was not worth the effort for me. Good luck

  • @tommycfchen
    @tommycfchen 3 роки тому

    You inspire me and I am going to get my dehum back in service......

  • @DEtchells
    @DEtchells 3 роки тому

    This is great, super helpful - Thanks!!

  • @jerrychan1471
    @jerrychan1471 4 роки тому +1

    Thank you for sharing this info. It was very helpful!

  • @inoahguy1578
    @inoahguy1578 5 років тому +10

    Freon is Dupont's name for r12 and r22. So I was a little confused when I was your video. But great instructional video keep up the good work. Btw if you dont like calling refrigerants by their number r410a can be called Puron.

    • @reganlebaron7103
      @reganlebaron7103 5 років тому +1

      Good to know, thanks for Watching

    • @egSmith-sp9gl
      @egSmith-sp9gl 5 років тому

      R12 is not in use anymore
      the most common now is r134a or Tetrafluoroethane

    • @paulmoffat9306
      @paulmoffat9306 4 роки тому

      @@egSmith-sp9gl R134a is used in automotive applications, R410a is used in most residential AC units.

    • @craigerickson1910
      @craigerickson1910 3 роки тому +1

      @@paulmoffat9306 This is outdated. R134a was used in cars starting in 1994 until recently. Many cars now use R1234yf as R134a is being phased out. Older residential A/C used R22 no longer being made. R410a is common now.

  • @BENZ007
    @BENZ007 Рік тому

    great videos

  • @darryllfulgar9387
    @darryllfulgar9387 22 години тому +1

    Where can I find the piercing valve and r410a can with hose and gauge?

  • @CUSTOMWORKS7.3PSD
    @CUSTOMWORKS7.3PSD 2 роки тому

    THANKS HEY Just got done doing a 1 year old fridgidaire 90 was a little scary the pressure gauge jumped from zero to 20 after alot of filling so patients folks let it cycle

  • @celestialdream49
    @celestialdream49 Рік тому +1

    Reganrepairs, thank you for the videos - nice job. I have a question: My dehumidifier is freezing up and I'm assuming the problem is it needs a charge. If my system is freezing up because it's low on coolant, doesn't that mean somewhere on my system there's a leak? If you don't find and repair the leak, isn't it just going to need (and keep needing) to be charged up with additional coolant?

  • @tskipwadoo3447
    @tskipwadoo3447 4 роки тому

    It makes total sense now, thank you for this vid.

  • @jasondepriest326
    @jasondepriest326 3 роки тому +1

    brilliant!

  • @runthenumbers9698
    @runthenumbers9698 Рік тому

    Thanks for the video
    I'm a bit confused though. I don't understand why the ice spread when you gave it more freon... and then when you gave it even more, the ice receded.

  • @jeffreynavallo6684
    @jeffreynavallo6684 2 роки тому +3

    Did the compressor get real hot to the touch when you recharged?

  • @jeffwen6120
    @jeffwen6120 Рік тому +1

    Hi,Thank you for your nice video,it is helpful!May I know what is the band for the R410A Refrigerant,and where can I buy it?could you please leave a link for R410A Refrigerant?

  • @421CentralIowa
    @421CentralIowa Рік тому

    Thanks for the info. Man, a can of R410a like this costs 140 dollars? That's the same price as a new dehumidifier. Can you just empty the system and replace with R134a?

  • @user-er6lz9nq4z
    @user-er6lz9nq4z Рік тому

    where did you get your gauge a push valve with hose , and the 410a

  • @gareld12
    @gareld12 4 роки тому

    thanks im going to try this , im a techy ,like new stuff,

  • @publicEnima
    @publicEnima 2 роки тому +4

    did you have to recharge it since the video?

  • @mariuszdy5843
    @mariuszdy5843 Рік тому

    awesome video, It's shame that R410A is being faze-out! Where did you get your gas from I'm struggling to find one here in Canada :(

  • @SpartanBrass
    @SpartanBrass 4 роки тому +5

    I’ll be damned it worked! Finding a hose for r410 wasn’t that easy but I’m ready to open up my own dehumidifier service business

    • @chrisglass7654
      @chrisglass7654 4 роки тому

      Jim ... what Bullet Valve did you use? Can you tell me the one you purchased?. They all seem to indicate they are not for use with R410A. I purchased a BPV31 but when I read the instructions it says not to use with R410A. Thank you.

    • @electricboyo
      @electricboyo 3 роки тому

      @@chrisglass7654 I wondered about this also. So I researched it and confirmed that bullet piercing valves are safe to use with R-410A when installed on the low side (suction line) only. This is the line from the evaporator to the compressor. It is usually covered with mastic or foam insulation. This is the line which gets cold when the unit is running. Note that R-410A has much higher operating pressures than R-22 or R-134A. Therefore it is wise to avoid making any connections to the high side, which may have several hundred PSI while the compressor is running.

  • @patrickhurley707
    @patrickhurley707 3 роки тому +2

    Did he provide the source for the filler device and Freon?

  • @curthatch8092
    @curthatch8092 2 роки тому +1

    Why could your not hold the R410A bottle the other way up and put gas into the system instead of liquid since liquid could be a problem to the compressor?

  • @MrAntosh73
    @MrAntosh73 11 місяців тому

    Hi, which way the fan blows?

  • @1marcelfilms
    @1marcelfilms Рік тому

    Can i put propane in my r22 vintage AC ?
    Cant buy any refrigerants here in europe

  • @Jolly-Way
    @Jolly-Way 4 роки тому

    Your straightforward demonstration on how to recharge a faltered dehumidifier encouraged me to try it also. I would appreciate if you could answer the following questions before I feel more confident to do try it myself. The dehumidifier in your demonstration looks (or is) the same as mine.
    What should the low/high pressure be in a normally working unit? - with motor running or not? The answer will help in estimating the loss of refrigerant after comparing the present pressure with normal pressure. Of course, the connecting valve (piercing valve) is always connected at the low side. Specs show that the pressure in a working unit is 290 - 580 PSIG. Is that range on the low side/suction side - when running? Presently the unit is not cooling down, i.e., not collecting water.
    Where would I be able to buy a recharge tank the size/type you are showing in the demonstration - and the cost?
    Your helpful reply would be appreciated.
    Best regards.

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому +3

      I purchased the same system just recently, and you can get it as a 'kit', which is the gas tank and a hose with a gauge. Always use the gauge that is intended for the gas being used, as the pressures do change (R22 is lower than R410a or R134). A 1.8 lb kit for R410a is about $135 US (Pro Charge brand) on eBay.

    • @Jolly-Way
      @Jolly-Way 3 роки тому

      Thank you very much for your very helpful reply.

    • @dane1976
      @dane1976 Рік тому +1

      Yeah, the cost is not worth it. Just buy a new one. If the coils have a hole anyway, you won’t have any choice.

  • @lordbyronofbedford5183
    @lordbyronofbedford5183 2 роки тому

    I have 3 units that need charging. How much refrigerant does one unit take approximately? Do I need to buy 5 pound tank?

  • @289r
    @289r Рік тому

    How much pressure in psi should the gauge show

  • @MichaelChanslor
    @MichaelChanslor 5 років тому +5

    Thanks for the video! Did the silver clamp on the compressor end come with the r410 kit? I'm looking at mine and I don't see any connectors for adding freon.

    • @waveriper20021
      @waveriper20021 4 роки тому +3

      Michael Chanslor its called a bullet piercing valve you can get on ebay or amazon

    • @kairamon8810
      @kairamon8810 3 роки тому

      You all probably dont give a damn but does anyone know of a trick to log back into an Instagram account..?
      I somehow lost my password. I would love any tricks you can offer me

    • @milomaxim9038
      @milomaxim9038 3 роки тому

      @Kai Ramon instablaster =)

    • @kairamon8810
      @kairamon8810 3 роки тому

      @Milo Maxim I really appreciate your reply. I got to the site through google and im trying it out now.
      Looks like it's gonna take a while so I will reply here later when my account password hopefully is recovered.

    • @kairamon8810
      @kairamon8810 3 роки тому

      @Milo Maxim It did the trick and I now got access to my account again. I'm so happy!
      Thanks so much, you really help me out :D

  • @kevinstiles286
    @kevinstiles286 2 роки тому

    Thank You for the demonstration, My compressor runs but there no frosting occurring. I’m assuming there’s no refrigerator gas in the system or it’s too low. I don’t have a valve g

    • @kevinstiles286
      @kevinstiles286 2 роки тому

      Sorry to add the gas , any suggestions. This unit is only 1 year old . GE model uses the 410A gas

  • @Jolly-Way
    @Jolly-Way 4 роки тому +1

    Your straightforward demonstration on how to recharge a faltered dehumidifier encouraged me to try it also. I would like to have your private email as I have some other questions.

  • @MrRene1968
    @MrRene1968 3 роки тому +5

    great info. I am curious. The refrigerant escaped, was the leak fixed before refilling?

    • @dane1976
      @dane1976 Рік тому

      Details 😂 with all the cost to get the stuff to repair it, cheaper to just buy a new one.

  • @thomaslynn8441
    @thomaslynn8441 11 місяців тому

    Hello, all I need is hose and gauge like your , where can you get them?

  • @sonyyoung1036
    @sonyyoung1036 2 роки тому

    Great video. Can you confirm where you installed the valve? Is it installed at the line coming out of the compressor where the freon has been compressed to a liquid?

    • @inhocsigno9151
      @inhocsigno9151 2 роки тому

      NO! Low Pressure side or Suction side. High pressure side could explode the can.

  • @Mocnoitang
    @Mocnoitang 4 роки тому

    what is suction psi would be it normal surrounding like 72 degree

  • @shenvalpress3535
    @shenvalpress3535 Рік тому

    I see you use R410A. It's not available to the DYIer it seems. Can R-32 suffice?

  • @ghostridergr8259
    @ghostridergr8259 2 роки тому

    i have ice to the first pipe or evaporator is noemal? how much is the the lowest temp to the evaporator in room temperature????? and how mutc is the highest temp to the compressor?? the ice.in the beginning of evaporator and before it is Normal??? i dont know how mutc gramms 407 i must put

  • @joehawthorn3018
    @joehawthorn3018 Рік тому

    My dehumidifier takes r22, can i put in 410

  • @mnew213
    @mnew213 5 років тому +26

    where to buy the Freon and the Gauge? Thanks

  • @winna101ify
    @winna101ify Місяць тому

    It would be nice if the type of refrigerent was stated in the video

  • @viktorsologub6837
    @viktorsologub6837 Місяць тому

    What the heck you get the valve in I take my dehumidifier part no valve to charge BS, and I have same exact brand Hisense

  • @John-dp3ln
    @John-dp3ln Рік тому

    Small appliances, proper way to do this is to evacuate the system and per the nameplate, weigh in exact amount. The demonstrated method works also but there is no guessing with weigh in method.

  • @mikemccartney59
    @mikemccartney59 2 місяці тому

    Any idea of E2 error on a Hisense?

  • @16DeathCore
    @16DeathCore 5 років тому +1

    Where did you get the hose ? Have Freon from auto parts store but it’s the quick disconnect not screw oh

    • @reganlebaron7103
      @reganlebaron7103 5 років тому

      Hi, the hose came with the Freon kit, but you can get the connectors on eBay cheap, thanks for Watching

    • @zachqueen8316
      @zachqueen8316 4 роки тому

      Don't use r134a it is not compatible with anything except r134a. If you aren't sure what refrigerant to use it should be marked on the compressor with the type of refrigerant and I compacity of refrigerant as well as the amount of oil required.

  • @Homer19521
    @Homer19521 5 років тому

    My 70 pint Hisense almost quit working. Just a little part of the condenser coil is cold. But I notice the compressor is very hot. Is that because it is low on freon or do they all get blazing hot? Thanx for the video.

    • @zachqueen8316
      @zachqueen8316 4 роки тому +1

      All the compressors get hot. Heat is a byproduct of compressing the refrigerant. As a fluid is compressed it gets colder therefore heat is released and as the refrigerant expands it gets warmer therefore heat is absorbed from the air this the reason the coils get cold or in the case of low refrigerant the refrigerant expands too much and the coils freeze over. If you have the correct amount of refrigerant in the system the coils will only condensate which is how the water is removed from the air.

    • @Homer19521
      @Homer19521 4 роки тому +1

      @@zachqueen8316 ZQ - I understand the concept of LHV (Latent Heat of Vaporization). I just wanted to know how hot does the typical dehumidifier compressor get. Maybe I didn't make that clear. Is 120F normal? 160F? 180F????

    • @zachqueen8316
      @zachqueen8316 4 роки тому

      Yeah sorry I didn't realize that. Most people don't realize understand it so I just figured I would post it in the event you didn't understand it. Typically though under normal operation they get hot enough that you can't typically hold your hand on them very long but not typically hot enough to burn instantly. As for specific operating temperature that I could not give you.

    • @ranckie
      @ranckie 4 роки тому

      @@zachqueen8316 In that case, a normal human hand can usually withstand about 125 degrees of heat before most people have to let go, so it sounds like based on your description, the compressor may get to be around 130 degrees or so F.

    • @inhocsigno9151
      @inhocsigno9151 2 роки тому

      @@zachqueen8316 Just to note that fluid can not be compressed. When gas is compressed by the compressor, the gas get hotter. The compr output line will be hot. When the gas goes thru the condensor coil it cools and condenses into a liquid. As the liquid goes thru the fixed orifice, it expands into a gas, cooling the coils. Your explanation on why coils freeze up sounds good.

  • @troyarthur829
    @troyarthur829 3 роки тому

    Love the video, its a great help, but the word is “Thaw” not “unthaw” which actually means “Freeze”... LOL... Sorry about that...

  • @roxyv8750
    @roxyv8750 4 роки тому

    I have Amana dehumidifier D970E-E and is not collecting water anymore. I assume I run out of Freon. Where can i find small quantity of freon. I assume should be R410A

    • @inhocsigno9151
      @inhocsigno9151 2 роки тому

      The label on the compressor should state what gas is used, and how much.tnks

  • @Dungtran-oc2hp
    @Dungtran-oc2hp Рік тому

    What the brand of Freon ?

  • @michelstellato6395
    @michelstellato6395 4 роки тому +1

    hi my dehumidifier Dandy need R410A, can Top it with another gaz, mixing with another gaz is ok or not, because a live in Canada and I find not R410A in automotive store

    • @zachqueen8316
      @zachqueen8316 4 роки тому +1

      Another gas is not ok the oils are not compatible. R410a is alot more expensive than r134a and is not sold it automotive stores as cars do not use 410a only 134a. If you mix the two refrigerants the oils will make a curdled milk like substance and destroy the compressor.

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому

      You can find vendors for a recharge kit for R410a on eBay (about $135 US), and they do ship to Canada.

  • @victoryfirst2878
    @victoryfirst2878 3 роки тому +1

    Why does the the line first freeze up and then stop ??? Can you put in a sealer with the gas to keep the unit from losing the gas ???

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому +1

      Many of the recharge kits have a sealant and UV dye indicator in the gas mix - the 410a kit that I purchased (Amazon) had that.

    • @victoryfirst2878
      @victoryfirst2878 3 роки тому

      @@paulmoffat9306 Thanks Paul for the information fella. VF

  • @flyingdaworld
    @flyingdaworld 3 роки тому

    I just purchased a secondhand refrigerant R290 dehumidifier. It’s called the corlitec dehumidifier. How do I know if it’s operating well? I’m afraid of a potential gas leak/carbon monoxide leak. Is a refrigerant dehumidifier capable of doing those things? Thank you.

    • @Joopsmann
      @Joopsmann 2 роки тому +1

      You’ll know it’s operating well when it dries a damp area. The evaporator coil gets cold to do that. If it isn’t pulling moisture from the air, it’s not working. Carbon monoxide leaks wouldn’t be possible. That’s an issue with natural gas or propane furnaces and water heaters. A refrigerant leak is possible. Toxicity isn’t a huge issue with a small system like a home dehumidifier. It can be with bigger systems.

    • @flyingdaworld
      @flyingdaworld 2 роки тому

      @@Joopsmann thank you for your reply! Would you say a completely electrical appliance is safer than a gas-run appliance?

    • @Joopsmann
      @Joopsmann 2 роки тому

      @@flyingdaworld I wouldn't say that gas appliances are "unsafe," just make sure your furnace flue is not blocked by leaves or a squirrel nest, etc. Not a bad idea to have a CO detector/alarm just like you most likely have a smoke detector. Your dehumidifier is electric though, right? (Electric motors turn the compressor and fan?)

  • @gerggry
    @gerggry 4 роки тому +2

    How long did it continue to run before needing another charge? I didn't see you address any leaks so I have to assume that's a temporary fix...

    • @zachqueen8316
      @zachqueen8316 4 роки тому +3

      Leaks aren't always the cause of the refrigerant loss. The refrigerant break's down over time and becomes sediment in the oil. Over several years of constant use you will eventually have to add more refrigerant.

    • @keninatlanta8452
      @keninatlanta8452 4 роки тому +5

      @@zachqueen8316 Can you provide just one textual reference that backs up your statement. These are closed systems engineered so the refrigerant is compatible with the oil. Here is a link from ACHR-News describing how oil and refrigerant react in an HVAC system. No mention of refrigerant breakdown over time. www.achrnews.com/articles/135762-inside-refrigerant-and-oil-relationships

    • @clintonrh
      @clintonrh 3 роки тому +3

      Ken is correct. There should be no refrigerant loss. These closed systems should run with no loss for 20 years. The fact that this is a new dehumidifier means there is a definite leak in the system that should have been addressed first! I do not recommend people doing what he did. Bullet valves are only good for a couple of years at most and are not intended to be opened and closed multiple times (this causes them to start leaking). The fact that he used a bullet valve, refused to repair the leak, and did not properly measure the refrigerant pressure in the system are all indicators that this unit will not function for very long or at efficiency level. This is why you do not buy used items like this on eBay. People like him are doing this and the units go bad in as month or two! Very bad repair video!

    • @user-sy6uo9vz6o
      @user-sy6uo9vz6o 3 роки тому

      @@clintonrh My dehumidifier did not collect water. I wonder how can I check the leaks that you just mentioned?

    • @clintonrh
      @clintonrh 3 роки тому +2

      @@user-sy6uo9vz6o Try adding something like cliplight super seal. It is for a/c systems and repairs leaks in the metal parts as well. The cheap stop leak products only work on non metal leaks so make sure what you get will repair metal leaks. Do not add the entire amount. Only about 1/4 of the canister. After it has circulated through the system, turn it off for a couple hours then turn it back on and refill with refrigerant. Before you do any of this, make sure the compressor is working. If the compressor is running but the coils do not get cold, the problem is low refrigerant. If you want to find the exact position of the leak, you can use an auto ac leak detector. The easiest way is to just use a leak repair sealant. Just be careful not to add too much sealant as it will limit how much refrigerant you can add.

  • @prolinelectricful
    @prolinelectricful 3 роки тому +3

    How many more times can you say uhh uhh? Damn

  • @dennisgostas5124
    @dennisgostas5124 5 років тому +1

    very nice thank you

  • @addmealready
    @addmealready 4 роки тому

    Does the dehumidifier have to be operating in order to remove the freon?

    • @normbutton537
      @normbutton537 2 роки тому

      No they apply a vacuum pump and draw the freon out

  • @yaoypl
    @yaoypl 5 років тому +4

    You must have a leak issue.. Did you fix the coil leak before your recharge?

    • @zachqueen8316
      @zachqueen8316 4 роки тому +1

      Leaks aren't always the cause of the refrigerant loss. The refrigerant break's down over time and becomes sediment in the oil. Over several years of constant use you will eventually have to add more refrigerant.

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому +2

      Most recharge kits, have the gas mixed with a UV leak marker and a sealing agent - that is why he was shaking the can to keep it mixed. Once filled, and running for a while, a UV light can show where the leaks are present. If the leak is a tiny pin hole, the sealant should do its job.

  • @nicolasrodriguez2440
    @nicolasrodriguez2440 5 років тому +1

    Hello! I really like your videos. Thanks for uploading them!!
    I wonder why a dehumidifier loses refrigerant so that it requires some recharging. I mean, does a refrigerant fade with no leaking in the system?
    I'd appreciate your kind reply.

    • @reganlebaron7103
      @reganlebaron7103 5 років тому

      I bought this unit as a refurbished item, I am going to assume that there must be a small leak some where, it’s a closed system, and theoretically it should not lose any refrigerant, Jon has a good explanation on charging in a previous comment.
      Thanks for Watching

    • @0GSoon
      @0GSoon 5 років тому

      I mad with the manufacture, new unit lasts only few years. Broken fan, noise or run dry on freon... too much problems...end up in scrap yard.

    • @petergabriel2593
      @petergabriel2593 5 років тому

      qiansview m

    • @zachqueen8316
      @zachqueen8316 4 роки тому +1

      Leaks aren't always the cause of the refrigerant loss. The refrigerant break's down over time and becomes sediment in the oil. Over several years of constant use you will eventually have to add more refrigerant.

    • @jonweigel2806
      @jonweigel2806 2 роки тому +1

      @@zachqueen8316 Freon doesn't wear out!! I have worked on units made 70 years ago! I can't imagine where you heard this, surely not from a competent repairman!

  • @kriskringle913
    @kriskringle913 4 роки тому

    Curious what if dehumidifier not blowing hot air, coils not cold, low refrigerant?

  • @josephmeckel7070
    @josephmeckel7070 10 місяців тому

    Where did you purchase the R410a refrigerant???

    • @Calliber50
      @Calliber50 5 місяців тому

      I got mine off ebay. Frosty-Freeze A/C Products Company. Just be careful. The cans may come with a little metal cap on the bottle. When unscrewing that cap, make sure you're in a room with no breakable items like windows or your fine china collection. Point the cap away from your face and slowly unscrew it. There may be substantial pressure and that cap will shoot off like a bullet. I was an idiot. Package arrived, I opened the box, I loosened the cap, there was a loud bang. Scared me, scared the dog, the wife screamed. The cap shot past my face and ricochet off a mirror. So I highly recommend a face shield or safety glasses when messing with these things.

  • @virusvirus3701
    @virusvirus3701 Рік тому

    how to remove freon from dehumidifier

  • @chevy77rock
    @chevy77rock 5 років тому

    What type of freon do you use?

    • @reganlebaron7103
      @reganlebaron7103 5 років тому +3

      My system uses r410, yours may use a different Freon, check the label on the side of the compressor, or on the side of the unit
      Thanks

  • @dave1026
    @dave1026 4 роки тому +7

    What it's actually doing is thawing. To dethaw or unthaw is to freeze.

  • @PRIDEMARTIALARTS
    @PRIDEMARTIALARTS 4 роки тому

    If my dehumidifier is blowing hot air is that a sign it needs freon?

  • @kodak_jack
    @kodak_jack 2 роки тому +1

    Do your viewers a favor and link to what you used in this video.
    When the system is charged properly, the frost will flash away and you're done.

  • @michaeldowling9120
    @michaeldowling9120 4 роки тому

    Can you use r134 instead?

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому

      No, should be same type to be compatible. Check the unit's label to verify the gas used.

  • @c.rutherford
    @c.rutherford 2 місяці тому

    This is no longer possible as the manufacturers have all conveniently discontinued R134a dehumidifiers which were the only ones that could realistically be recharged- even though they run better. Most have also switched to ridiculously short 1 year warranties.
    Planned obsolesence.

  • @byron821
    @byron821 21 день тому

    This makes no sense to me.... the freon leaked out but you didn't repair the leak. It's just going to leak out again? I've had several dehumidifier units. None of them lasted more than 2 years. Why can't any American company make a dehumidifier that LASTS?

  • @772777777777777
    @772777777777777 Рік тому

    Most unit do not have the shudder value on the unit

  • @g1g1420
    @g1g1420 Рік тому

    That's the evaporator

  • @Jon-hx7pe
    @Jon-hx7pe 5 років тому +9

    This isn't an accurate charging method. It will get the machine running, not necessarily optimally and there's a possibility of liquid refrigerant getting back to the compressor. You can overcharge or undercharge depending on the operating conditions. There's no required psi, it greatly varies depending on the operating conditions and design of the unit.
    DIY kits like this aren't good because they increase the likelyhood of the work being done incorrectly. Need recovery machine, proper gauges, thermometers, vacuum pump, brazing torch, nitrogen, plus knowledge of theory to do refrigeration work correctly. People think charging is like inflating a tire.
    These units have fixed metering devices, so there are two valid methods:
    1. Superheat - temperature rise above boiling point. boiling point determined by pressure and sunction refrigerant temp measured with insulated or clamp thermometer. Subtract measured temp from saturation temp. Normally the required superheat depends on the operating conditions and there are tables indicating what the superheat should be for a/c. But in a dehumidifier application, because the condenser is cooled by cold air from the evap coil and the temp of the cold air is proportional to the load on the evap coil, it should stay pretty consistent. It should be anywhere from 5 to 15F degrees. The ideal superheat is 0 with no liquid getting to the compressor, but manufacturers design for above that to be sure no liquid gets back.
    2. Weight, which requires recovering all the refrigerant and weighting in the amount on the rating plate. This is the best method for small appliances like this.

    • @reganlebaron7103
      @reganlebaron7103 5 років тому

      Thanks for the explanation, thanks for Watching

    • @ilovefunnyamv2nd
      @ilovefunnyamv2nd 4 роки тому

      Yeah, but accurate would be sending it back to the factory with the people who made it 6-12 years ago, next best would be a licensed HVAC specialist familiar with the process and coolants, if not this specific model. But still, if you were going to throw it out and buy a new anyway....

    • @Jon-hx7pe
      @Jon-hx7pe 4 роки тому

      the charge can be weighed in, the amount of refrigerant is on the rating plate. can also get it very close to factory checking superheat/subcool.

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому

      @@Jon-hx7pe That method works it the unit is emptied of it's remaining gas load.

    • @paulmoffat9306
      @paulmoffat9306 3 роки тому +1

      @@ilovefunnyamv2nd Most HVAC don't want to service a small unit - not enough money for the call. They may service it if you bring it to their shop.

  • @chitownvaulter
    @chitownvaulter 5 років тому

    how much refrigerant was left in the can after you recharged it?? or how many times can you recharge it with one can??

    • @ilovefunnyamv2nd
      @ilovefunnyamv2nd 4 роки тому

      All that depends, When I recharged my car, I used most of a can, when I did my parent's, I think I had to used a can between them

  • @ES-AT
    @ES-AT 3 роки тому

    R410 is not a freon. it is a Puron

  • @ardiemclelland2039
    @ardiemclelland2039 5 років тому +4

    Buy an old dehumidifier and you’ll never have a leak issue.

  • @dandillon5163
    @dandillon5163 2 роки тому +1

    Not worth it. First it’s not fixed. It will need to be charged again and again. Second - valve and Freon cost. If the dehumidifier has a low side leak it may last longer. If it has high side leak it won’t last long at all. Problem dehumidifier is poorly made.

  • @TruePatriot59
    @TruePatriot59 2 роки тому +1

    Not worth fixing...I agree with other comments here...too expensive for the freon and valve.

  • @bladder1010
    @bladder1010 4 роки тому +2

    But where can I get r410a freon? I can't seem to find a bottle like you have for sale to the public anywhere?

    • @AS-TIGTV
      @AS-TIGTV 4 роки тому

      If you're humidifier needs r410a, only licensed person can purchase the freon and that is by law implementation.

    • @bobs7597
      @bobs7597 3 роки тому

      410a is not restricted. Can be found on the internet ......it’s not cheap, but it’s available to the general public.

    • @bladder1010
      @bladder1010 3 роки тому

      @@bobs7597 So, basically, my dehumidifier is garbage. No economical way to recharge it.

    • @stevescherer4954
      @stevescherer4954 2 роки тому

      @@bladder1010 The coils and refrigerant can be recycled and other parts used to repair other units.

  • @knowyuhgrow420
    @knowyuhgrow420 2 роки тому

    👍🏽

  • @PaineStakingTruth
    @PaineStakingTruth 8 місяців тому

    Sorry, the word is “thaw”. That alone means ice or frost is eliminated. De-thaw or un-thaw is nonsensical.

  • @g1g1420
    @g1g1420 Рік тому

    Still low

  • @qtig9490
    @qtig9490 4 роки тому +1

    You are filling on the low pressure side so why not just flip the freon can right side up? That way you dont inject the liquid just the gas which is what you wanto to keep from damaging your compressor with a slug of liquid.

    • @BatByke
      @BatByke 4 роки тому +1

      You cannot charge R410A as gas, only liquid. R401A is a composite of different refrigerants, not a single like R12 and R22, If charged as gas, the lower fraction boils off first giving you the wrong gas, which will change the mixture both in the supply bottle and the device being charged.

  • @chempennllcthechemicalcomp1438
    @chempennllcthechemicalcomp1438 4 роки тому

    Hello,
    thank you for using one of our product in your video. I would like to discuss with you opportunities. Please contact me at sales@chempenn.com at your early convenience.

  • @apher2012
    @apher2012 Рік тому

    Need to make a better effort on the way you speak up description, sound like you are trustworthy repair man

  • @holdurhorse9149
    @holdurhorse9149 5 років тому

    It shouldn't frost at all. The frosting indicates the system is overcharged!
    What is sub cooling limits and over heated vapor rules fall in the play?
    Overcoming would flood the compressor and it eventually get damaged.

    • @bobs7597
      @bobs7597 3 роки тому +3

      Wrong...under charge

  • @Lil_Taco
    @Lil_Taco 2 роки тому

    Just recorded yourself committing a federal offense lmao you can not under any circumstances let refrigerant in the atmosphere

  • @JR-hh8ou
    @JR-hh8ou 3 роки тому +1

    Quit saying you are using Freon you are using refrigerant Freon is a brand name made by DuPont!!! Unless you're using Dupont refrigerant then you may say freon.