(हिंदी में) - Part-2: Overcurrent & Earth Fault Protection | PSM | TMS | IDMT | Relay Coordination

Поділитися
Вставка
  • Опубліковано 1 лют 2025

КОМЕНТАРІ • 27

  • @satyendrabharati7319
    @satyendrabharati7319 14 днів тому

    Really Sir, great teaching.

  • @ranjansahu2362
    @ranjansahu2362 Рік тому +1

    Excellent explanation... Big and prolonged doubt is almost clear....

  • @ganeshdhurve876
    @ganeshdhurve876 Рік тому +1

    Excellent explanation. Today, I got relay coordination perfectly.

  • @AMITKUMAR-ds4hp
    @AMITKUMAR-ds4hp Рік тому +1

    Excellent video ❤

  • @souravmondal8507
    @souravmondal8507 Рік тому +2

    Thank you very much sir.

  • @surendrakverma555
    @surendrakverma555 8 місяців тому

    Very good. Thanks Sir 🙏

  • @md.rabiulhasanmazumder321
    @md.rabiulhasanmazumder321 4 місяці тому

    Nice presentation, indeed. Could you please tell me about the earth fault (50N/51N) protection setting?

  • @ImranKhan-nu6xw
    @ImranKhan-nu6xw Рік тому +1

    thanks sir for your generosity

  • @AMITKUMAR-ds4hp
    @AMITKUMAR-ds4hp Рік тому +1

    Thank you sir

  • @zarghamkhan8288
    @zarghamkhan8288 10 місяців тому +1

    Request to please make some conceptual videos on tertiary winding. Love from Pakistan. Doing excellent job sir

  • @FarhanKhan-cx4yg
    @FarhanKhan-cx4yg 6 місяців тому

    Sir I am Farhan from Karachi water & sewerage bord recently hamara HT< penal upgrade howy he is me incoming VCB me fannox ki rely lagai Gai he us rely ki setting k bary me Kuch bataen

  • @razmasoom
    @razmasoom 10 місяців тому

    Sir how to calculate fault current?. In system we see lots of variation in fault current recorded by relay.

  • @sumitmazumdar8505
    @sumitmazumdar8505 Рік тому

    Sir please upload pdf also if possible, that will be so helpful... Anyway your videos are great

  • @lavkushmishra6937
    @lavkushmishra6937 Рік тому

    Sir,
    If we measure value on behalf of current then why do we consider voltage in grading margin?

    • @LIGHTNINGMINDS_PANKAJKUMARJHA
      @LIGHTNINGMINDS_PANKAJKUMARJHA  Рік тому

      Voltage is considered for polarisation I.e. for determination of direction in case of directional over current relay. Voltage is not considered for grading margin. If you see non directional relay, then voltage is not required.

  • @sambithota-le7pf
    @sambithota-le7pf 9 місяців тому

    what is relay reset time in protection coordination not clear sir.

  • @prasadgore235
    @prasadgore235 Рік тому +1

    Sir Take an Example where utility gives only let say 550mS for max fault with SI curve and you got 3 steps coordination down stream. I face a problem when curve goes to minimum definite time and that time does not grade over full range. Any solutions for that.

    • @LIGHTNINGMINDS_PANKAJKUMARJHA
      @LIGHTNINGMINDS_PANKAJKUMARJHA  Рік тому

      This is the problem with over current relay, you can’t coordinate with all conditions because over current protection depends upon source impedance. Some numerical relay gives the option to create custom curve (r.g. NR OCS 902/931), in some relays have the option to set minimum time of operation for IDMT or we can set additional time delay ( e.g. ABB Make Relays)….. However the coordination is difficult in complex networks.

  • @ZDGamer53
    @ZDGamer53 Рік тому

    sir TMS kia ha

  • @electricalengineer6064
    @electricalengineer6064 Рік тому +1

    1st view