Delta MS300 External Terminal Operation Control

Поділитися
Вставка
  • Опубліковано 23 лип 2024
  • How to configure operation commands (run/stop/direction) for the control terminals on the Delta MS300.
    downloadcenter.deltaww.com/en...

КОМЕНТАРІ • 26

  • @jakubzborowski6426
    @jakubzborowski6426 2 роки тому

    Thank's, very helpfull video. Greetings from Sohbi

  • @pauldering6539
    @pauldering6539 5 місяців тому

    thank you very much.

  • @ReyRelacion
    @ReyRelacion 28 днів тому

    How to use the multi function relay output and what are the parameters thats need to set up? thank you.

  • @cerita-ceritanabi3343
    @cerita-ceritanabi3343 6 місяців тому

    Hi, I would like to ask a question. How to save our parameter setting at ms300? because I when I was turn off the inverter and tried to running again, the inverter need seeting again

  • @MrBibinkk
    @MrBibinkk 2 роки тому

    Sir i need to work this drive as a counter is it possible.. I tried but it didn't work

  • @julioarias260
    @julioarias260 26 днів тому

    Hello there. Can this VFD be controlled by an RC-01 accesorie ? Thanks

  • @controlmate75
    @controlmate75 2 роки тому

    can we take out the digital panel and use an extension wire or something so you can transfer the digital panel on the door of the main panel?

    • @deltavfd6406
      @deltavfd6406  2 роки тому

      Yes there is a keypad extension cable. The part numbers are in the accessories section of the manual.

  • @raynelson3404
    @raynelson3404 2 роки тому

    I am wanting to run a vacuum pump for my cnc table. I was to told split the wire from the vacuum on switch and put it on m1 and vcm. Is this a safe method to run the drive?

    • @deltavfd6406
      @deltavfd6406  2 роки тому

      As long as it is a dry contact from MI1 - DCM and no additional power given to the drive control terminals, then yes.

  • @jimmontgomery8982
    @jimmontgomery8982 3 місяці тому

    Thank you for your video. I'm needing parameter setting information for using an external braking resistor. Can you help?

    • @deltavfd6406
      @deltavfd6406  3 місяці тому

      Hello, check parameters 06-01 and 07-00. Search for "brake resistor" in the manual pdf.

  • @0Saints0Photography0
    @0Saints0Photography0 2 роки тому

    Hi Can you do a video of how to connect the MS300 to use a 24v pulse to increase and decrease the frequency if possible?

    • @deltavfd6406
      @deltavfd6406  2 роки тому

      Using an external 24VDC input, see the control terminal wiring fig 6-5 in the manual.
      Pulse input - the frequency of the pulses determines the speed. Check the description in parameter 10.16
      External Up / Down - 00.20, 02.01 ~ 02.07 set to 19 and 20

  • @mattchu79
    @mattchu79 2 роки тому

    Can I bypass it by connecting a wire from MI1 to DCM bcuz I want it to run as soon as I activate the external switch that provides power to it

    • @deltavfd6406
      @deltavfd6406  2 роки тому

      Yes, also check 00.21 for external terminals and 02.35 setting to enable it

  • @pds4927
    @pds4927 Рік тому

    Hi, can you do a video on how to configure the ms300 to a lathe machine(Grizzly / Powermatic) using external switches/buttons to run the run/forwar/stop/reverse

    • @stevelillie4597
      @stevelillie4597 7 місяців тому

      Hi pds4927. I'm Steve. I am trying to do just that..get an MS300 inverter to work on a PM 3520B. Did you ever have any luck configuring it with your lathe? I'm desperate. There are many more options than the original S inverter.

  • @fungelelanimaster8668
    @fungelelanimaster8668 Рік тому +1

    ❤️ 💞

  • @mrbonah8561
    @mrbonah8561 Рік тому

    What about if the wires are 5. Control nob has 3 wires. Start and stop has 2 wires. How can I connect it

    • @deltavfd6406
      @deltavfd6406  3 місяці тому

      The potentiometer is covered in a separate video on connecting analog input.

  • @user-fx8mv6jr1y
    @user-fx8mv6jr1y 10 місяців тому

    Do you do consulting?

  • @hapzc.j.
    @hapzc.j. Рік тому

    fan not function how to

  • @r.dmotorcontrolworks5066
    @r.dmotorcontrolworks5066 Рік тому

    Hellow sir...can you pls create video tutorial about 4 20ma using ms300..tnx

    • @deltavfd6406
      @deltavfd6406  Рік тому

      Hi, for 4-20mA use the ACI terminal as signal and ACM terminal as common. For speed reference, 03.00 = 0, 03.01 = 1, 00.20 = 2. For PID feedback, 03.01 = 5.