Pump Cavitation & Net Positive Suction Head Basics I NPSH Derivation

Поділитися
Вставка
  • Опубліковано 21 вер 2024

КОМЕНТАРІ • 37

  • @MechStudies
    @MechStudies  6 місяців тому +1

    At time 21.14 : please read NPSHa>NPSHr: we will make a detail video on relationships

  • @freshpipes38
    @freshpipes38 2 місяці тому +3

    Great effort for animated presentation. For correction, rotation arrow is supposed to be counter flow or backward-inclined flow. As per Bernouli's principle when the velocity increases the pressure should decrease to balance the flow. And to avoid cavitation pump NPSH-R should be less than to what is available (NPSH-A)..Ergo NPSH-A > NPSH-R..Nicely presented just need some corrections.

    • @MechStudies
      @MechStudies  2 місяці тому

      Thanks the error is at last few seconds and we have already acknowledged thanks

  • @tarisaichingwere3824
    @tarisaichingwere3824 Місяць тому

    Thank you for such a clear and easy to follow presentation

  • @myokyawsan8153
    @myokyawsan8153 Місяць тому +1

    At 21:14 on Your presentation "NPSHr > NPSHa " . it is not correct for the NPSHr (Net Positive Suction Head required) to be greater than the NPSHa (Net Positive Suction Head available). In fact, for a pump to operate properly and avoid cavitation, the NPSHa must be greater than or at least equal to the NPSHr. This can be expressed as:
    NPSHa≥NPSHr
    If the NPSHa is less than the NPSHr, the pump will likely experience cavitation. Cavitation occurs when the pressure in the pump falls below the vapor pressure of the liquid, causing the liquid to vaporize and form bubbles. These bubbles can collapse violently when they move into higher pressure areas within the pump, potentially causing damage to the pump impeller and other components, reducing efficiency, and causing noise and vibration.
    To ensure safe and efficient pump operation:
    NPSHa: The actual pressure head available at the pump suction, considering atmospheric pressure, static head, velocity head, and subtracting vapor pressure and friction losses.
    NPSHr: The minimum pressure head required by the pump to avoid cavitation, specified by the pump manufacturer.
    Always make sure that: NPSHa≥NPSHr
    Anyway your presentation is excellent .... Thank you so much.

  • @MohamedFathy-gr9cg
    @MohamedFathy-gr9cg 6 місяців тому +4

    Great effort .. hanks for the information .. one point to be corrected if possible: NPSHa > NPSHr

    • @MechStudies
      @MechStudies  6 місяців тому +1

      Rightly pointed out, it’s an error at the last minute, actually we have a plan to post second video where these details will be captured, thanks

    • @MohamedFathy-gr9cg
      @MohamedFathy-gr9cg 6 місяців тому +1

      Good Luck and waiting for your new video :)

  • @anilpal5947
    @anilpal5947 11 місяців тому +2

    Very very thanks for sharing valuable knowledge , I request to you please upload about mechanical seal configuration and plan

  • @tilahunberihane1648
    @tilahunberihane1648 7 місяців тому +3

    Wow keep it up

    • @MechStudies
      @MechStudies  7 місяців тому

      Thank you so much for visiting us❤️❤️❤️

  • @বেঙ্গলিমোটিভেশন
    @বেঙ্গলিমোটিভেশন 11 місяців тому +2

    Nice explanation.

  • @KakaKaka-s6o
    @KakaKaka-s6o 2 місяці тому +1

    many thanks for This video and all information but i have a notice NPSHA always bigger than NPSHR

    • @MechStudies
      @MechStudies  2 місяці тому

      Correct, it’s a line at the last moment .. error.. we will make second part in details

  • @tarisaichingwere3824
    @tarisaichingwere3824 Місяць тому

    I think also in the case of a pump below the suction point at the base of a reservoir tank, the fluid head in the tank should be considered as well

  • @EAR.Pakistan
    @EAR.Pakistan 6 місяців тому +1

    In last, You said the NPSHR must greater than NPSHA. If available is less than required, how it works?

    • @MechStudies
      @MechStudies  6 місяців тому

      This is a mistake … at the last second…🙏 will make second video for all these details

  • @abdulwali9939
    @abdulwali9939 9 місяців тому +10

    NPSHa > NPSHr

  • @anilpal5947
    @anilpal5947 4 місяці тому

    Please upload more videos about mechanical seal, and glass lined reactor

  • @abdulraheem.a9774
    @abdulraheem.a9774 8 місяців тому +1

    Nice Explanation, Thank you

  • @H2O1167
    @H2O1167 Місяць тому +1

    What if the suction source is above the pump?

  • @brokenarrow5590
    @brokenarrow5590 5 місяців тому +1

    How come velocity and pressure can be increased at the same time 🤔

    • @MechStudies
      @MechStudies  5 місяців тому

      😄

    • @freshpipes38
      @freshpipes38 2 місяці тому

      He is not following Bernouli's principle. He has his own principle..lol

  • @JohnMann-o3z
    @JohnMann-o3z 2 дні тому

    Martinez Amy Rodriguez Matthew Clark Christopher

  • @aliabdulqader2881
    @aliabdulqader2881 6 місяців тому

    Suction pressure is P2 and not th total pressure ...the dynamic pressure V²/2g should be not added but subtract from Pa🙏

  • @RaviSharma-xi4ly
    @RaviSharma-xi4ly 21 день тому

    19:34

  • @Trudeautthebestt
    @Trudeautthebestt 3 дні тому

    Who is this guy ? Bro go home 😂

  • @howardalexander6785
    @howardalexander6785 5 місяців тому

    Shouldnt be killing humans though