Phase failure and under & over voltage master control motor circuits protection relay

Поділитися
Вставка
  • Опубліковано 27 сер 2024
  • Phase failure and under & over voltage master control motor circuits protection relay
    In this video we can see you full introduction these protection
    of motor with ZAHRA Rst 25 Master Control Relay
    phase failure protection
    Low voltage protection
    High voltage protection
    phase change protection
    When circuit supply is OFF Then 11-12 piont closed
    When circuit supply is ON Then 11-12 Open & 11-14 closed But no any Fault
    When Apply any fault of circuit then 11-12 alarm point closed
    Main common point 11
    Circuit Control point 14
    Fault and alarm Point 12
    Circuit Diagram link
    2.bp.blogspot....
    You can see more electrical videos visit and subscribe our channel
    UA-cam channel: / motorcircuits
    Web blog: motorcircuits.b...
    facebook page: facebool.com/mo...
    Subscribe Now
    Phase failure relay circuit
    phase failure protection
    phase failure relay operation
    phase failure relay working principle
    phase failure zahra rst 25
    phase failure zahra
    phase failure relay siemens
    phase failure relay schneider
    phase failure relay wiki
    phase failure relay
    phase failure relay
    Under & over voltage relay
    high and low voltage relay

КОМЕНТАРІ • 95

  • @seelearn1822
    @seelearn1822 10 місяців тому

    Very well explained you are deserve like and subscribe.

  • @faisaljatt6195
    @faisaljatt6195 Рік тому

    Best Video very good yaar ye tareqa best h bs last wali veriable ka b bta dety

    • @motorcircuits9538
      @motorcircuits9538  Рік тому

      بھائی لاسٹ والی وہ ٹائمنگ کی ہے کہ کتنی دیر کے اندر سرکٹ بریک کر کے سٹارٹر کو اوپن کر دے

  • @muhammadaaghar8595
    @muhammadaaghar8595 5 років тому

    App ka samjhny ka andaz bohat hi acha hai

  • @waseemkhan1895
    @waseemkhan1895 Рік тому

    Vido achi hy voice very pkaoo

  • @maddumabandara1124
    @maddumabandara1124 Рік тому

    good explain

  • @ranaawais3818
    @ranaawais3818 4 роки тому +1

    Good bro

  • @youceftarek2764
    @youceftarek2764 7 років тому

    we wait your new everyday... thank you .el Salem aalykom

  • @user-zj1bj1tw6z
    @user-zj1bj1tw6z 2 роки тому

    اللهم صل وسلم على نبينا محمد

  • @Chaudhary-concrete
    @Chaudhary-concrete 3 роки тому

    ماشاءاللہ

  • @shaiksawant460
    @shaiksawant460 7 років тому

    mashaallah best job

  • @bobybhai4407
    @bobybhai4407 5 років тому

    Nice friend

  • @sohailnattentertain4555
    @sohailnattentertain4555 7 років тому

    Mashaallah good vidoes

  • @AliMalik-mf5ut
    @AliMalik-mf5ut 7 років тому +2

    sir please guide us or give us solution to control low and high voltage at home as home appliances burnt when voltage goes up secondly we also face issue that when KESE comes some times the high voltage comes in neutral wire and things burn our even off things also burt. your effort are always be highly appretiated. God bless u.

    • @ssharpeyes
      @ssharpeyes 7 років тому

      my question to the brother as your's ... same issue .. hope he give us the safe true solution ...

    • @RohitRajput-ev8rw
      @RohitRajput-ev8rw 6 років тому

      Use Under Voltage Relay..

    • @bilalahmadbil3999
      @bilalahmadbil3999 6 років тому

      Ali Malik use protection relay if you want contact us

  • @shahid90001
    @shahid90001 7 років тому

    power facter relay ore capicter bank k bare me koi vedio banaye shukria

  • @binmushtaq2740
    @binmushtaq2740 7 років тому

    Thanks for such valuable information. Will appreciate if you advise, what equipment should be install with control panel to insure a stable 220 v in the house for all accessories. We are facing big fluctuation is power supply. 360v high to 30v low.

  • @thecliphut5093
    @thecliphut5093 5 років тому

    Sir make videos on voltage relay and ELR

  • @ankjhabib8564
    @ankjhabib8564 7 років тому +2

    jnab 2 malomat dain 1)AC motor ko Dc kasy karna hai or ic ki speed ko control kasy karin gai 2)serf AC motor ki speed up/down kasy control Karin gai jwab zaror dsyina thanks

  • @youceftarek2764
    @youceftarek2764 7 років тому

    good all times

  • @hajishajuneja8884
    @hajishajuneja8884 5 років тому

    Panal control boad bnate he Kya kitni kimt he 25 HP submersible Motor ke liye chahiye please jankari de assalmualaykum

  • @Deepak094093
    @Deepak094093 6 років тому

    Dear friend, I have a two pahse submersible and have to use same type relay to save my motor from pahse imbalance at low and High voltage. Please suggest me the perfect relay for using two phase.

  • @fahimasghar6375
    @fahimasghar6375 7 років тому +1

    Sir Relay se voltage kam ya ziada kr k nahi btaya k relay under voltage ya overvoltage pe operate hoti hei ya nahi?

  • @muhammadaaghar8595
    @muhammadaaghar8595 5 років тому

    Sir VFD ke bary main bhi explain karen

  • @subhabratabasu266
    @subhabratabasu266 5 років тому

    iska price kitna hai?
    aur apke pas iska koi online purchase karne ka link hai to provide kijie..............
    thank you

  • @muhannadhasan7714
    @muhannadhasan7714 7 років тому

    Thank you for movie can you speak for setting over and under voltage

    • @motorcircuits9538
      @motorcircuits9538  3 роки тому

      please watch complete video of under/V and over laod relay

  • @mumar4091
    @mumar4091 3 роки тому

    Bhai ye PE per kya lagana hy

  • @rajeshm.rajesh4977
    @rajeshm.rajesh4977 4 роки тому

    415volts Fcma Softstarter voltage
    Relay connection

  • @muhammadmuhsin9026
    @muhammadmuhsin9026 5 років тому

    Sir over load relay b laga k cmplte Dol with phase failure video upload kr dijiye

  • @MujeebKhan-jb6th
    @MujeebKhan-jb6th 3 роки тому

    Sir singal phase me ye relay ati he

  • @muhannadhasan7714
    @muhannadhasan7714 7 років тому

    Can you speak for generator test

  • @imran3055
    @imran3055 6 років тому

    Sir plz make a controll on water level, when water level goes down then motor(sumbersible pump) stop, when water level increase then motor start, with all safety, plzz

  • @lumensolution7377
    @lumensolution7377 3 роки тому

    Agr relay ko home ki main DB connect kerna ho to os ka kya tarika h

    • @motorcircuits9538
      @motorcircuits9538  3 роки тому

      bilkul yahi tarika hy ..conatactor stip per he lagy ga

  • @fahimasghar6375
    @fahimasghar6375 7 років тому

    Sir RST 25 ki relay pr setting hei kiya hum us se voltage ki setting change kr k dekh sakte hein ?

  • @pabangope2520
    @pabangope2520 4 роки тому +1

    Sir Rely kaha milega mujhe chahiye

  • @mianmunib2555
    @mianmunib2555 2 роки тому

    Sir Humra pa's nutl ni ha 3 fac hn to kia kra

  • @alisha2494
    @alisha2494 3 роки тому

    dear ham is ZAHRA Rst 25 ko bypass kisy kr skty han?

  • @shafiqurrahman915
    @shafiqurrahman915 7 років тому

    good movie

  • @shafiqurrahman915
    @shafiqurrahman915 7 років тому

    Good movie

  • @saeedkhan386
    @saeedkhan386 2 роки тому

    background music unnecessarily disturbing

  • @MAbid-zt7nm
    @MAbid-zt7nm 5 років тому

    Sir kya main is relay ko ek 80 amp kay contactor ko control kernay kay liye laga sakta huin.
    Or is contactor kay agaya 3 mcb laga ker un per 3 alag machines chalani hain.
    Plzz is baray main advice dain

  • @azharbashir5374
    @azharbashir5374 4 роки тому

    Salam Bhai kitne amp Tek lagy ga

  • @ashraftanha1861
    @ashraftanha1861 6 років тому

    Sir ap nay motor kai output wire nahi lagay sir iskay baray main be samja dain

  • @ahilcuts7971
    @ahilcuts7971 5 років тому

    How to set reset manually

  • @electricaleducationtelugu3412
    @electricaleducationtelugu3412 7 років тому

    ok but can possible motor input ok but output loss

  • @user-fd7if8rm5b
    @user-fd7if8rm5b Рік тому

    চমত্কার

  • @khyberzamawatan3321
    @khyberzamawatan3321 7 років тому

    samaj tu aa gai per magnetic starter say motor ko supply kahan say den gay relay say ya magnetic starter say

    • @muhammadmuhsin9026
      @muhammadmuhsin9026 5 років тому

      Contacter se de ge

    • @motorcircuits9538
      @motorcircuits9538  3 роки тому

      this is only control circuits, but you are connect main supply in magnetic starter main pole and out put on below side ...

  • @bilalahmadbil3999
    @bilalahmadbil3999 6 років тому

    Sir starter lagan zrori ha kya?

    • @motorcircuits9538
      @motorcircuits9538  3 роки тому

      starter ko motor ke protection ky ly lagaya jata hy bro

  • @irfanmehar5602
    @irfanmehar5602 7 років тому

    Sir mujy isi ky sath auto b lagana hy jaisy ky water ful ho jay to moter bnd ho jay or agr manul chalana chahin to wo b chalay orgent please

    • @irfanmehar5602
      @irfanmehar5602 7 років тому

      Sir jo ap ny wo video jo bnae hy os ma timer use kiy hain mujy same isi conection ma bus float switch lga daina hy bus

    • @irfanmehar5602
      @irfanmehar5602 7 років тому

      Ok thanks bro

    • @irfanmehar5602
      @irfanmehar5602 7 років тому

      Sir aap ay nae

    • @irfanmehar5602
      @irfanmehar5602 7 років тому

      Sir aap ny bataya nae k kaisy lagy ga?

    • @MrNulenur
      @MrNulenur 4 роки тому

      Sir we use this technology to submarsible pump ? From Karnataka

  • @afstudio7111
    @afstudio7111 2 роки тому

    Sir ya ats system my kasy lagy gi

    • @motorcircuits9538
      @motorcircuits9538  Рік тому

      اے ٹی ایس کی ویڈیو چینل میں موجود ہے وہ آپ چیک کر سکتے ہیں

  • @technologyofbangladesh1936
    @technologyofbangladesh1936 4 роки тому

    If the motor is off running, phase

  • @Nextlife657
    @Nextlife657 7 років тому

    Sir meri relay operate niii hooo rhe same connection kr dya han jase ap ne n kie han. Off show kr rhiii hai. On niii hooo rhiii

  • @VinayKumar-ed5gl
    @VinayKumar-ed5gl 7 років тому

    bhai yeh kaha milega Muje chaiye kyon Hamare Yaha akser voltage high ho jata hai..

  • @electricaltech4u45
    @electricaltech4u45 7 років тому

    Dear bro .u change phase 1 to 2 its not work ok.check again 1to 3 its work y plz mention.???

    • @electricaltech4u45
      @electricaltech4u45 7 років тому

      Dear bro because u check ur device.its fine its phase rotation.

  • @davidadanu9430
    @davidadanu9430 5 років тому

    Please can some one help me the video of an automatic 3phase change over in English

  • @bobybhai4407
    @bobybhai4407 5 років тому

    Is ma a1 a2 Ka nhi bataya

  • @amrishrana4826
    @amrishrana4826 7 років тому

    sir muja single phase k ley under or hight voltage device hai koi

    • @bilalahmadbil3999
      @bilalahmadbil3999 6 років тому

      Amrish Rana g ha bhai over and under Voltage relay

  • @Nextlife657
    @Nextlife657 7 років тому

    Please guide me

  • @shakirgaddi6060
    @shakirgaddi6060 3 роки тому

    Holl