    In this video, you’ll learn how to connect to the Fluke Connect app to save your measurements virtually and learn how to test a motor.
    With the Fluke 1587 FC, you can find small problems before they turn into catastrophic failures. Electrical current unbalance can be caused by bad wiring or insulations problems within the motor.
    Learn more about the 1587 FC: bit.ly/2Lnv5Kt
    #Fluke1587 #InsulationTester

КОМЕНТАРІ • 31

  • @faithorfate1989
    @faithorfate1989 6 років тому +6

    Please do some more videos on this meter as it relates to the megger. I am a maintenance tech and I earned a degree in electrical but some of the functions are hard to understand how to navigate through.

    • @fluke
      @fluke  6 років тому +1

      Hi Charles - Thank you for the feedback! Do you have any questions right now about the 1587 FC that we can help answer?

  • @leonardocorrea5790
    @leonardocorrea5790 Рік тому +1

    Why was the temperature not entered for compensation?

  • @chrisa1495
    @chrisa1495 3 роки тому +2

    Since this is a 480V motor, why use 1000V instead of 500V considering each phase carries an average of 277V and in case of a fault may not carry more than 500V?

    • @davismelville1404
      @davismelville1404 Рік тому +2

      He said the range has to be doubled around 1:10 minutes

    • @donacianoc.sandoval2587
      @donacianoc.sandoval2587 2 місяці тому

      When you test the insulation of a motor winding, you don't test for what's its rated at. The insulation test is a stress test, doubling the voltage puts a heavy duty load on the windings, and if the windings hold, then your insulation is solid. If it doesn't hold, and you're bleeding to another winding or to ground, then you have a compromised winding. Motors dead at that point most likely, or extremely weak depending on how bad the leakage is.

  • @waynehenson1094
    @waynehenson1094 4 роки тому

    Thank you for that lesson.

    • @fluke
      @fluke  4 роки тому

      Thanks for watching, Wayne!

  • @ryandestiny6
    @ryandestiny6 2 роки тому

    I bought fluke 1587FC yesterday, but i had doubts about the description assembled in USA , where is the manufacturing country?

    • @fluke
      @fluke  2 роки тому +1

      Thanks for your question. You'll find that various components are sourced from many countries - but if it says assembled in the USA, then that's where it was put togehter ;-)

  • @juanolivo4704
    @juanolivo4704 5 років тому +2

    Can you make a video on an AC compressor. Thank you

    • @fluke
      @fluke  5 років тому

      Hi Juan - What are you specifically looking to learn about AC Compressors?

    • @juanolivo4704
      @juanolivo4704 5 років тому

      @@fluke I'm sorry, can this meter check the windings on an AC compressor and a small video would be nice.

    • @fluke
      @fluke  5 років тому

      Hi Juan - Here is a helpful video on making current measurements with the 1587 FC: bit.ly/2NG1AaM
      We also have some helpful learning material on our website: bit.ly/2NMYjqp
      If you have any additional questions, please let us know. Thanks!

  • @pzt1688
    @pzt1688 2 роки тому

    What kind of file format is used for downloading test results? MS Excel or some sort? What is the data sampling rate? What info can be included in the downloaded file?

    • @fluke
      @fluke  2 роки тому

      Peter - thanks for your questions: The data sent from 1578FC to phone/app is a binary file. It can be exported as XLS, CSV, or PDF. You can add text and voice notes, and assign the measurement to Asset and/or work order.

  • @vincentfrancissotto
    @vincentfrancissotto Рік тому

    I own a Fluke 1587 FC Insulation Multimeter and every time I try to use the PI or DAR functions, the value displayed on the screen is "> 2.2 GOhm" at 1000V which means that the actual reading could be more than 2 GOhms?. After around 20-30 seconds, I receive an error message, and "Err" is shown on the screen. However, after watching your video that had DAR and PI values displayed, is it because the readings are within the range of the multimeter? Can anyone offer insight into why I'm receiving this error and how I can resolve the issue? Thank you in advance for your help.

    • @waxstache
      @waxstache 6 місяців тому

      Did you find some info for that? I have the same issues

    • @vincentfrancissotto
      @vincentfrancissotto 6 місяців тому

      @@waxstache I received a table from Fluke regarding the interpretation of DAR and PI values:
      DAR 0-1.0 and PI 0-1 is Dangerous.
      DAR 1.0-1.3 and PI 1-2 is Poor.
      DAR 1.3-1.6 and PI 2-4 is Good.
      DAR 1.6 and above and PI 4 and above is Excellent.
      Therefore, if you're receiving an error message during the PI or DAR tests, it actually indicates an Excellent result, meaning your insulation resistance is higher than the meter's display range. This is a good sign for insulation testing!

  • @williamgombert7710
    @williamgombert7710 3 роки тому

    Could this device be used to check whether a capacitor leaks or not?

    • @f1reguy587
      @f1reguy587 Рік тому

      Leaks? You can keep a test over time but if you remain connected, your meter would consume the charge. Thats my understanding so far…

  • @MrAdamtheplumber
    @MrAdamtheplumber 4 роки тому

    I’ve just bought the fluke 1587 FC. Can fluke or anyone else inform me why it comes up with error when using pi and dar timed measurements on it? The measurements are holding to it’s maximum resistance on each setting yet it says err after about 1 minute. Thanks.

    • @fluke
      @fluke  4 роки тому

      Hi Adman - Our Technical Support team would be happy to help troubleshoot. Please give us a call at 1-800-443-5853 or email fluke-info@fluke.com. Thank you!

    • @vincentfrancissotto
      @vincentfrancissotto Рік тому

      I actually have the same problem. I maybe late but I hope Fluke provided you an answer.

  • @mousdewaga
    @mousdewaga Рік тому

    it would have been nice if it has a buzzer for the failed insulation test

  • @goranhikl1180
    @goranhikl1180 4 роки тому +1

    What if you don’t have a cell phone

    • @fluke
      @fluke  4 роки тому +2

      Hi Goran - You can access and download the Desktop Version of Fluke Connect here on our website: bit.ly/315ONTS. Thanks!

  • @naderhumood1199
    @naderhumood1199 5 років тому

    Aptly Fluke can make. ....it

  • @jrobles1019
    @jrobles1019 3 роки тому

    I was taught to megger phase to phase as well not only to ground ? The insulation could also start to go bad there not just to ground. On that test you should see your resistance keep in building. Thanks for nothing I guess horrible video

    • @manganiphiri4331
      @manganiphiri4331 2 роки тому +1

      If the motor is connected in star configuration you would get zero.

    • @darrenproudlock8575
      @darrenproudlock8575 2 роки тому

      It's good practice to check resistance between the phases they should be balanced. Then you only need mega one phase