Tal vez necesites conectarlo porque la batería está descargada. Intenta calibrarlo nuevamente. Si no funciona, es posible que tengas que abrir la parte trasera y desconectar los cables de la batería.
Hey man, great videos. I do have a question about error 3 and 4 for the 900b ex. As well as when a scale head is powered on and just has dashes and won’t let me do anything.
error 3 is input signal is negative. This usually happens when the green and white wires are swap and giving a negative signal. You can check the C15 setting to see how it responds to weight. The video on the channel called how to fix a floor scale explains more about this. error 4 happens when weight is unstable. Usually customers put too many decimals that their scale can't handle. Try to use less decimals and try out. If it still happens then probably damaged cable to readout. Check C15 setting as well. I haven't seen the dashes probably overload or short in cable. Try to go into settings and recalibrate. email: support@optimascale.com for any specific questions you have.
@@optimascale6851 hermano,con mucha sinceridad agradezco el tiempo que te has tomado para contestarme.Te comento rápido,que yo calibré esa báscula la cual se usa para pesar ganado y el punto está que una vez calibrada cuando se realiza prueba de peso con una res el peso se mantiene oscilante,no estable.podría ser falta de configuración en la sensibilidad?
Happens when weight is not stable. Make sure your test weight isn't moving. If it is not moving then check the wiring in the junction box in the platform. It could be 1 wire loose. Watch my how to fix a floor scale video on more details. Thanks, Anthony
If the indicator is 10+ years old then you would need to use 10% of capacity to calibrate. If newer than that check the wiring in the platform. There is video on channel on how to fix floor scale. Follow cable to junction box in platform and open that up. Check wiring in there. Might be a wire loose or in wrong order. They should all be in the same order. Thanks, Anthony
Legend for making this!! Thanks
Hola buenos días disculpe para comentar por qué al prender el aparato sigue la secuencia marca error6 y se apaga
Tal vez necesites conectarlo porque la batería está descargada. Intenta calibrarlo nuevamente. Si no funciona, es posible que tengas que abrir la parte trasera y desconectar los cables de la batería.
Hey man, great videos. I do have a question about error 3 and 4 for the 900b ex. As well as when a scale head is powered on and just has dashes and won’t let me do anything.
error 3 is input signal is negative. This usually happens when the green and white wires are swap and giving a negative signal. You can check the C15 setting to see how it responds to weight. The video on the channel called how to fix a floor scale explains more about this.
error 4 happens when weight is unstable. Usually customers put too many decimals that their scale can't handle. Try to use less decimals and try out. If it still happens then probably damaged cable to readout. Check C15 setting as well.
I haven't seen the dashes probably overload or short in cable. Try to go into settings and recalibrate.
email: support@optimascale.com for any specific questions you have.
Best video man helped me out alot
Thanks for being a customer.
Buen día Como configurar Para agregarle o quitarle decimales. Tengo un MODEL OP-900A MS. Gracias
Puedes usar la configuración de CO2 para establecer la cantidad de decimales que desees.
Hola estimado amigo,podrías indicarme las configuraciones para poder calibrar un indicador de peso para ganado op-900 ?
C01-2
C02-0
C03-1
C04-5000
C05-1
C06-1
Tengo un manual en español en nuestro sitio web aquí.
www.optimascale.com/manuals
Thanks,
Anthony
@@optimascale6851 hermano,con mucha sinceridad agradezco el tiempo que te has tomado para contestarme.Te comento rápido,que yo calibré esa báscula la cual se usa para pesar ganado y el punto está que una vez calibrada cuando se realiza prueba de peso con una res el peso se mantiene oscilante,no estable.podría ser falta de configuración en la sensibilidad?
INDICADOR BKCscales calibration please
This is for calibration. Si busca a alguien que pueda ayudar en español puede llamar al 1.800.360.9619 ext. 2 tenemos gente aquí que puede ayudar.
Error 4? Plis
T scale err4
Happens when weight is not stable. Make sure your test weight isn't moving. If it is not moving then check the wiring in the junction box in the platform. It could be 1 wire loose. Watch my how to fix a floor scale video on more details.
Thanks,
Anthony
@@optimascale6851 thank you, for showing me how to overcome it
Error 2?
If the indicator is 10+ years old then you would need to use 10% of capacity to calibrate. If newer than that check the wiring in the platform. There is video on channel on how to fix floor scale. Follow cable to junction box in platform and open that up. Check wiring in there. Might be a wire loose or in wrong order. They should all be in the same order.
Thanks,
Anthony
Vc 50 cely err6
Espani