- 184
- 191 913
Optima Scale
United States
Приєднався 31 лип 2018
Videos on calibration procedure, settings, and troubleshooting for Optima Scale products. Managed Technical Support for Optima Scale.
Accumulating Multiple shipments with a small Zebra Printer OP900 with OP412 L1 printer
Accumulation mode on the OP900 with the L1 printer. This is how to print.
Переглядів: 21
Відео
Weight Fluctuating on Pallet Jack, Try This
Переглядів 4114 днів тому
If a load cell is bad turn it over to the side you will find the load cell bolted on to the frame. Unwire from the junction box and remove bolts. Take out old load cell and put new one in.
New Style OP903 Set Date Video 9/26/2024
Переглядів 55Місяць тому
New Style OP903 Set Date Video 9/26/2024
New Style OP903 Calibration Video 9/26/2024
Переглядів 382 місяці тому
New Style OP903 Calibration Video 9/26/2024
Bench Scale not Working? What to check for.
Переглядів 2542 місяці тому
Bench Scale not Working? What to check for.
Weighing small items up to 30Kg with accuracy 0.1lbs / OPH-Z Calibration
Переглядів 802 місяці тому
OPH-Z Calibration video OPH-Z10 - 10 kg x 0.1 g 13” L x 13” W x 5” H Pan Size: 12” x 9” OPH-Z20 20 kg x 0.1 g OPH-Z30 30 kg x 0.1 g
OP909 Plus Count Feature
Переглядів 7844 місяці тому
New indicator that is NTEP stainless steel has a keypad with the count feature shown in this video. Email: sales@optimascale.com for more details
New OP903 Setting to print multiple copies (RePrint Feature)
Переглядів 585 місяців тому
Setting the RePrint feature on the new OP903
New OP903 disabling the store print setting
Переглядів 575 місяців тому
New OP903 disabling the store print setting
OP903 Setting Date and Time New Style
Переглядів 198 місяців тому
OP903 Setting Date and Time New Style
OP900B-EX 4-20ma Settings and Demonstration
Переглядів 140Рік тому
OP900B-EX 4-20ma Settings and Demonstration
How to read Data over Serial using Com Ports
Переглядів 7 тис.Рік тому
How to read Data over Serial using Com Ports
Connecting Scale Over Fiber Optic Cable Software Installation
Переглядів 15Рік тому
Connecting Scale Over Fiber Optic Cable Software Installation
What is the use of junction box and how potentiometer in junction box will be used?
Protection: Safeguards electrical connections from environmental and mechanical damage. Organization: Provides a central point for managing electrical wiring connections, making maintenance easier. Safety: Reduces the risk of short circuits, fire hazards, or electrical shocks by containing and insulating connections. Signal Calibration: In sensor systems, potentiometers are used to fine-tune signal levels for calibration, ensuring the sensors operate within desired ranges. Adjusting Output: It may regulate output voltage or current in circuits, allowing customization of electrical parameters to match system requirements. Balancing Circuits: Potentiometers can balance circuits or adjust offsets in control systems, ensuring stable and accurate operation. Thanks, Anthony
have formula mv to temperature?
Hola buenos días disculpe para comentar por qué al prender el aparato sigue la secuencia marca error6 y se apaga
Tal vez necesites conectarlo porque la batería está descargada. Intenta calibrarlo nuevamente. Si no funciona, es posible que tengas que abrir la parte trasera y desconectar los cables de la batería.
Error 2?
If the indicator is 10+ years old then you would need to use 10% of capacity to calibrate. If newer than that check the wiring in the platform. There is video on channel on how to fix floor scale. Follow cable to junction box in platform and open that up. Check wiring in there. Might be a wire loose or in wrong order. They should all be in the same order. Thanks, Anthony
i did this and got it to say 0lbs but now its not reading any weight. It just stays at zero
Did you make sure you put weight during the adload on the screen. If you did correctly try 1 more time. If that doesn't work you might have a problem with your OP902. You would need to replace the indicator with a new indicator like our OP909. They are $165 + tax + shipping. You can email sales@optimascale.com to purchase. Typically these OP902 have problems like this after a couple years. Thanks, Anthony
Mine is broke, where i can find other one?
email: sales@optimascale.com Send a photo of which model you have.
It connects but doesn't give me any data. Does any one know why? cause` the prompt apperas but there`s no data in there
You might need to check the indicator settings to ensure it is set to continuous and that the correct baud rate is selected. If the settings are correct, you may need a null modem cable, as pins 2 and 3 are swapped. However, if you are already using a null modem cable, try switching to a regular (non-null modem) cable. Alternatively, you can purchase a DB9 null modem adapter (male to female). The female end plugs into the DB9 male connector of the cable, which then connects to the indicator. This will also swap pins 2 and 3. Pin 2 is TX (Transmit), and Pin 3 is RX (Receive) on the DB9 connector. These items are readily available on Amazon. If none of this works, there might be an issue with the internal board. Finding the correct cables and null modem adapters can be tricky. Thanks, Anthony
@@optimascale6851 I'll try, thank you dude
Buen día Como configurar Para agregarle o quitarle decimales. Tengo un MODEL OP-900A MS. Gracias
Puedes usar la configuración de CO2 para establecer la cantidad de decimales que desees.
Good
Sir I have dis model Problem cod erro6 what problem dis
Typically try to calibrate like in the video. If that doesn't help maybe problem with main PCB. You might need to check the wiring. Here is another video on the channel about this. ua-cam.com/video/tVbT5GvMI-o/v-deo.htmlsi=m8ziorYWR2xXBqfO Thanks, Anthony
I spent 2 hours trying to figure it out on my own with the manual and in less than 2 minutes of video... I've finally got it working! Thank you!
Glad it helped! -Anthony
Thank you for the tutorial
Nice 👍
Please can u install floor scale without junction box
No since there is 4 load cells. The indicators only have room for 1 connection. You can connect one load cells directly to indicator but that is all. Other option would be to buy OP903 which has 4 5 pin connectors and attach a 5 pin connector to each load cell and connect that to each port of 903. Thanks, Anthony
Hola estimado amigo,podrías indicarme las configuraciones para poder calibrar un indicador de peso para ganado op-900 ?
C01-2 C02-0 C03-1 C04-5000 C05-1 C06-1 Tengo un manual en español en nuestro sitio web aquí. www.optimascale.com/manuals Thanks, Anthony
@@optimascale6851 hermano,con mucha sinceridad agradezco el tiempo que te has tomado para contestarme.Te comento rápido,que yo calibré esa báscula la cual se usa para pesar ganado y el punto está que una vez calibrada cuando se realiza prueba de peso con una res el peso se mantiene oscilante,no estable.podría ser falta de configuración en la sensibilidad?
This was very helpful. Thanks!
Hello, where can you buy the white color printer and program?
Sorry for taking long time to respond. Email sales@optimascale.com to place your order. Anthony
Hm
I've tried this but it just doesn't work for me. It connects but doesn't give me any data.
have you checked your port?
thank you for detailed explanation. Surprisingly there arent that many videos on the subject
Ours won’t zero out.
If your readout is older than 2-3 years old there might be a problem with the readout. You might need to replace. We discontinued the OP902 and replaced with OP909JR. Ask for the 4 to 5 pin adapter. email: sales@optimascale.com to place order. Otherwise it could be damaged cable someone is sales can help you with that. Anthony
What position should the lever on the handle be when you install it?
About 45 degrees
@@optimascale6851 I'm sorry, I meant the three-position operational handle lever
Legend for making this!! Thanks
how can get that indicator...i need 1
Email sales@optimascale.com to purchase.
Thank you
Now they are good values so load cells are good How we knew if they are bad if ot comes morr resistamce??? 😊
Only way to check is add voltage over red and black and measure output resistance as weight is being added.
for windows, the program used was Putty, this also works on linux, where the port(s) are /dev/tty.... e.g. ttyACM0, ttyUSB0 the linux user (not root) might need to be part of the dialout group, do the following in a terminal (need sudo rights) sudo adduser $USER dialout (where $USER points to the current logged in active user, or replace it with your logon name )
Kindly make single ponit loadcell making compelete process vidio.
amazing. big thanks
question, there is a wireless version of this, what is the name of the board used for making it wireless?
You can use what you want. We have used the digi xbee in the past.
Anthony
Where can I purchase a replacement battery for my pallet jack, I can't seem to find them anywhere.
email sales@optimascale.com with which color battery you have we have in stock.
How can 12 cells be connected together?
You can use a 12 port junction box. We only have 10 ports here. Second option is to use to SECTIONAL junction boxes for example 2 8 port junction boxes where 1 goes into into to the input of the other junction box. Diagram would be readout -> junction box 1 (4 load cells) -> junction box 2 (8 load cells).
Necesito el esquema de como soldarlo
Rojo-TX Verde - RX Negro-tierra
Hey man, great videos. I do have a question about error 3 and 4 for the 900b ex. As well as when a scale head is powered on and just has dashes and won’t let me do anything.
error 3 is input signal is negative. This usually happens when the green and white wires are swap and giving a negative signal. You can check the C15 setting to see how it responds to weight. The video on the channel called how to fix a floor scale explains more about this. error 4 happens when weight is unstable. Usually customers put too many decimals that their scale can't handle. Try to use less decimals and try out. If it still happens then probably damaged cable to readout. Check C15 setting as well. I haven't seen the dashes probably overload or short in cable. Try to go into settings and recalibrate. email: support@optimascale.com for any specific questions you have.
How do you turn on the Battery Indicator??
It should turn on when pressing the power button up front. Make sure power cables connected. Anthony
Nice
is there a way to have this print in Excel
You would need some kind of software. Here is a video below on an example software we make. ua-cam.com/video/MjL-30WFqMM/v-deo.html
Thank you for your demo for calibration. It worked for the ULINE floor scale too.
Yes, we ship for ULINE as well. Sometimes they rebadge our scales as their own or find another supplier and do the same. All scales work the same so the any videos on this channel will help. Anthony
Thank you
where download Software ?
We sell this software. You can email: sales@optimascale.com to purchase. Mentions you want to buy data logging software. They can give you a price.
@@optimascale6851 thank you .
I like
Espani
Love your videos bro. I work for Data Weighing Systems out in Wood Dale IL and your videos help me a lot. Question, are those batteries rechargeable or will they need to be replaced every year or so?
These are reachable. Same as a phone they are not meant to be replaced. These batteries should last from 3-5 years depending on how often they are used. Anthony
Very useful 👌.. i want to know what happens when we calibrate a weighing scale.changes occurs in indicator? or in load cell?
Calibration is stored on the indicator. Load cell is just a sensor. If you take the calibrated indicator and switch load cells to a different load cell of same capacity it will weigh the same.
I was wondering if you can help with my scales , my scales were send out and working from who sent them but upon receiving them they didn't work, I pulled them apart to find what looks like a wire soldered in wrong spot could this be why they say unstable
I turn on my scale and all is says is "un-st then after a moment fluctuates in weight to 14kg and then goes to o-ld " it doesn't start up normally it just says unst ...
You can watch my video on how to fix a floor scale for a more detailed answered. ua-cam.com/video/wcZWCF0RN1U/v-deo.html It could be wire in the wrong location, maybe needs to be recalibrated or bad load cell. Only way to tell is making sure all wiring is correct and tight and recalibrate. If there is water in the junction box then that will cause fluctuating weight. You will need to replace that junction box. You can email sales@optimascale.com for junction box replacement or if you find a bad load cell. Thanks, Anthony
WE HAVE STRUGGLED WITH THIS INDICATOR FOR YEARS.
Yes it is difficult. If you have a problem with one port you can check the F4 raw data for that connector and see what is going on. You can email: support@optimascale.com with your problem for more help.
Error 4? Plis
T scale err4
Happens when weight is not stable. Make sure your test weight isn't moving. If it is not moving then check the wiring in the junction box in the platform. It could be 1 wire loose. Watch my how to fix a floor scale video on more details. Thanks, Anthony
@@optimascale6851 thank you, for showing me how to overcome it
700Ω
Check the green and white wires and check that ohm reading. Then Green and black should be around the same. Load cells usually don't go bad. Try to rewire and check the C15 setting. Check out how to fix a floor scale video for more details. Thanks, Anthony
Load cells
Vc 50 cely err6