SURFACE CONDENSER || WORKING & PRINCIPLES OF SURFACE CONDENSER IN HINDI ||

Поділитися
Вставка
  • Опубліковано 8 тра 2020
  • Hello friends,
    "Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
    Rankine Cycle explained in Hindi :-
    • Rankine Cycle || Therm...
    Sensible heat & Latent heat :-
    • SENSIBLE HEAT और LATEN...
    Working and principles of Steam jet Ejector system :-
    • EJECTOR SYSTEM || WORK...
    Working and principles of Hogger:-
    • FUNCTION OF HOGGER || ...
    Email
    powerplantdiscussion@gmail.com
    Website
    / @powerplantdiscussion (Company Website)
    LinkedIn
    / power-plant-discussion...
    #PowerPlantDiscussion
    #SurfaceCondenser
    Thanks to all of you for connecting me.

КОМЕНТАРІ • 138

  • @chotuabhijit1885
    @chotuabhijit1885 3 роки тому +1

    Sir AAP bht ache se smjahte ho bht acha lga condenser ka video ☺️

  • @prafullchand2344
    @prafullchand2344 4 роки тому +2

    Very nice explanation sr

  • @narendratiwari1297
    @narendratiwari1297 4 роки тому +5

    Well done!

  • @tushartiwary3883
    @tushartiwary3883 4 роки тому +3

    Thanks Sir fr the Info.. 🙏😊

  • @shailendrajadon3599
    @shailendrajadon3599 4 роки тому +4

    Nice information sir...

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Thanks dear

    • @shailendrajadon3599
      @shailendrajadon3599 4 роки тому +2

      Good morning sir ..
      FD compartment jab hum open karegei to air bleed valve close ho jata hai.. Aur jab compartment close karegei to air bleed valve open open ho jata hai.. Aisa kyo.... Please reply sir..

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Air bleed means air remove from windbox and another function is that if plant trip then CO gas having higher density which removes from this bleed valve, I'll make seperate video on this topic as soon as possible.

    • @shailendrajadon3599
      @shailendrajadon3599 4 роки тому +1

      OK sir....

    • @Radhekrishnamathura435
      @Radhekrishnamathura435 11 годин тому

  • @ankitbairagi7903
    @ankitbairagi7903 Рік тому

    Bhut sandar

  • @mdmasudhasan1144
    @mdmasudhasan1144 3 роки тому +1

    very very good sir

  • @mukeshkur3557
    @mukeshkur3557 4 роки тому +3

    Thanks a lots sir

  • @SumitYadav-zd8tm
    @SumitYadav-zd8tm 4 роки тому +2

    Very nice sir

  • @vaibhavichaudhary8814
    @vaibhavichaudhary8814 3 роки тому

    Very nice Tq sir bhaut Ache se samj aaya 🙏🏻🙏🏻🙏🏻

  • @dipeshakhiya8919
    @dipeshakhiya8919 3 роки тому +2

    Good explained 👍

  • @vimalraulaji3516
    @vimalraulaji3516 Рік тому +1

    sir you r great. Really appreciate your effort.

  • @afzalrashid50
    @afzalrashid50 11 місяців тому

    explain with drawing and actual its very easy to understand

  • @hariprakashreddy1999
    @hariprakashreddy1999 3 роки тому +1

    Tq for good video sir

  • @pratyushdubey237
    @pratyushdubey237 2 місяці тому

    Very nice sir 👌👌👌

  • @harekrushnaacharya7862
    @harekrushnaacharya7862 4 роки тому +2

    Well explained sir... thank u ..🙏🙏

  • @shokeenchoudhary6253
    @shokeenchoudhary6253 3 роки тому

    Very good sir g

  • @sunilmishra5382
    @sunilmishra5382 4 роки тому

    Badhiya bhaii

  • @khandelmahesh6557
    @khandelmahesh6557 4 роки тому +2

    Very good persecution

  • @mohdamir95287
    @mohdamir95287 4 роки тому +3

    Vaccum pump pr video bnaye sir

  • @Akshayvalvi1583
    @Akshayvalvi1583 2 роки тому

    Very nice

  • @shubgameryt1667
    @shubgameryt1667 23 дні тому

    Nice

  • @amitraj-ht3pn
    @amitraj-ht3pn 4 роки тому +3

    Sr main cooling water pump ka pressure kitna hota h

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Dear it depends on designing normally seen 2.5 kg/cm2 to 3.5kg/cm2

  • @sachindhamunia195
    @sachindhamunia195 3 роки тому +1

    great initiative, great explanation

  • @RobinKumar-cj1hq
    @RobinKumar-cj1hq 4 роки тому +1

    Thank you sir.... Plz condenser ke formule pr v video bno sir

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Today I'll upload on Calculation of quantity of cooling water inside surface condenser

  • @shaileshbirajdar3170
    @shaileshbirajdar3170 3 роки тому +1

    👏👏

  • @sathyanarayanvm5935
    @sathyanarayanvm5935 4 роки тому +5

    Sir please explain start up procedure for steam turbine's.

  • @mayurvilasdarne5572
    @mayurvilasdarne5572 3 роки тому +2

    Please add the video specially for evaporative condenser.. sir

  • @jaik420
    @jaik420 Рік тому

    exam se 2 ghante phle notes banane ka alag maja hai

  • @raushankumarbt8to941
    @raushankumarbt8to941 Рік тому +1

    Jay hind sir

  • @vaibhavichaudhary8814
    @vaibhavichaudhary8814 3 роки тому +1

    Sir jet condenser bhe bata dejiya 🙏🏻🙏🏻pls sir 🙏🙏🙏

  • @GalaxY2.000
    @GalaxY2.000 4 роки тому +1

    Verry... nice sir

  • @leelaprakash8930
    @leelaprakash8930 9 місяців тому

    Sir, Please make a video on Pressure Reducing Desuperheater, explaining the terms, Blending, Dumping, condensate formation etc.,
    Thanks in advance sir.

  • @merajwarsi6952
    @merajwarsi6952 3 роки тому +1

    Sir Bahut achhe se smjhate ho but ek or request karunga ki aap ye bolte ho ki ye laga hota hai to plz uske bare me ye bhi batayen ki kyon laga hota hai or nahi lagane se kya hoga........Ek aap video banaye jisme working of power plant ho...

  • @kanwalkumar8093
    @kanwalkumar8093 2 роки тому

    Amazing sir ❤️

  • @vishuumarani1627
    @vishuumarani1627 3 роки тому +1

    Dear sir can you give information about, how to calculate heating surface area and how to know, how effectively heating surface is working...

  • @yadvendradubey510
    @yadvendradubey510 4 роки тому +2

    Jandar Sundar

  • @amalkrishnapa7713
    @amalkrishnapa7713 9 місяців тому

    Nice
    What is the mame of centrifugal compressor having 4suction and one discharge?

  • @mohdamir95287
    @mohdamir95287 4 роки тому +2

    Is pr numerical kraye sir

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +2

      Ha Mai iska numerical Kia hu jisko bahut jald upload kr dunga dear, jisme Calculation h no of tube, quantity of cooling water, and their efficiency.

  • @aadilshaikh7177
    @aadilshaikh7177 2 роки тому

    Sir spray dryer absorber par video bnao...mass balance
    Or rotary kiln energy balance

  • @shailendrajadon3599
    @shailendrajadon3599 4 роки тому

    Good afternoon sir... Please make video working on throttle valve and governor...

  • @arunchoudhary8179
    @arunchoudhary8179 4 роки тому +2

    Dear larg q banaya jata h..
    Chota hoga tho kya problem hoge

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Steam Ka volume jyada hota h comparatively to water so slightly larger make

  • @SumitKumar-pl2em
    @SumitKumar-pl2em 4 роки тому +2

    Sir maine pahile v aapse request kiya tha ki aap lp, hp, b&s, and reducer Pump ka work ball coal mill me kyon hota h.? Please solve this problem sir

  • @sadabahmed1510
    @sadabahmed1510 4 роки тому +2

    Why cold water enter from bottom and exit from top...why not reverse direction

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +2

      If we provide at top side then heat transfer rate is more in top side, so cooling water gain heat and become as higher as steam temperature so half bottom if these hot cooling water circulated the heat transfer rate is negligible, so to proper heat transfer in Condenser, firstly water provide from bottom side some amount of heat absorbed after that top half remaining absorbed.

  • @bikerfromsoul2440
    @bikerfromsoul2440 3 роки тому +1

    Sir thora regenerative surface condenser samjha dijiye

  • @nareshammatanaresh3188
    @nareshammatanaresh3188 4 роки тому +1

    So2 and No2 volues mg/Nm3 to kg and tones conversation how with example

  • @amarmaurya2745
    @amarmaurya2745 Рік тому

    Sir condenser me laga rapture disc kiss condition me fatata hai ek vedio banaye

  • @nikunjadas8687
    @nikunjadas8687 3 роки тому +1

    air cooling condenser video please. 🙏🙏

  • @rasmiranjannayak4257
    @rasmiranjannayak4257 3 роки тому +1

    Hi sir make screw compressor video ..

  • @VikramYadav-fw5iq
    @VikramYadav-fw5iq Рік тому

    Sir kya chiller ke condenser me bhi refrigerant ka latent heat hi reject karvate hai?

  • @sampatvasave4447
    @sampatvasave4447 2 роки тому

    Air cooled condenser ka video banavo sir

  • @pinkoosaket9460
    @pinkoosaket9460 2 роки тому

    Pls sir vacuum cooling line up information

  • @raneomkarsuresh5970
    @raneomkarsuresh5970 Рік тому

    Please Make video on regenrative surface condenser 🙏🙏

  • @AmanVerma-rc2pq
    @AmanVerma-rc2pq 2 роки тому

    Bhai....forward feed evaporator backward feed me bht confusion hoti hai...kab backward use karna chayie...
    Viscous ya phr cold feed hai to ku backward use karte hai vertical tube agitated type kb use karte hai please samjhaaye

  • @gopalsaini1965
    @gopalsaini1965 2 роки тому

    Turbine dcs ke bare Mai btaiye

  • @shasvattripathi6169
    @shasvattripathi6169 2 роки тому

    Condenser ke andar entropy kam hogi ya jayeda hogi sir so please tell me

  • @archanavaka9258
    @archanavaka9258 4 роки тому

    Sir Could you explain about regenerative aph

  • @biswajitmangaraj7793
    @biswajitmangaraj7793 4 роки тому +1

    SIR make a vd on acc

  • @Mohammed_Hanif1
    @Mohammed_Hanif1 3 роки тому +2

    The main Objective is to maintain the low (i.e below atm pr.) Then how it comes true the condenser is constant pressure latent heat extracting device.

  • @Nevergiveup0021
    @Nevergiveup0021 11 місяців тому

    Sir ACC type ko bataiye isme thoda function change rehta hai

  • @sunilmishra5382
    @sunilmishra5382 4 роки тому

    Plzz explain different types of cycle in TG area (like condensate,steam,feedwater)

  • @DurgaPrasad-fm2rl
    @DurgaPrasad-fm2rl 3 роки тому +1

    boiler hot lightup afbc

  • @uniqueworldpk5936
    @uniqueworldpk5936 4 роки тому +2

    پلیز کنڈنسر کی ٹائپ بتائے Tell us type of condenser

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +1

      M unable to read this language, question is not clear please write totally in English.

    • @uniqueworldpk5936
      @uniqueworldpk5936 4 роки тому

      @@PowerPlantDiscussion tell about condenser types?

  • @AmandeepSingh-qd1cp
    @AmandeepSingh-qd1cp 4 роки тому +1

    Mdfp and tdfp pumps ki ek video jrur bnaoo

  • @santoshkumar-cf1pv
    @santoshkumar-cf1pv 4 роки тому

    Sir,please reply why exhaust hood temperature increases while rolling of turbine.Please sir explain with some details.Thanks sir.

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +2

      The whole kinetic energy of steam is not utilised during turbine rolling, so due to accumulation of these energy gradually increase of temperature and if synchronisation done then proper utilisation of kinetic energy by turbine, so this temperature start decreasing, I'll make seperate video on this topic.

    • @santoshkumar-cf1pv
      @santoshkumar-cf1pv 4 роки тому

      @@PowerPlantDiscussion Thanks sir.when is next vedio coming?

  • @shasvattripathi6169
    @shasvattripathi6169 2 роки тому

    Kya effect padega entropy pay

  • @sachinsahu504
    @sachinsahu504 4 роки тому +2

    Sir, why we restrict the temperature difference upto 10°C of cooling water.

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +1

      Because we only remove latent heat of exhaust steam in condenser, if exhaust steam having higher temperature (means loss of Turbine efficiency) then this delta temperature increases, so we design condenser only for removing such a latent heat means both steam and condensed water having same temperature only phase change after cooling in condenser. This 10°C is constant means if more heat available in steam which is not condensed in condenser so the accumulation of non condensing gas increases which drops the vacuum so we takes action on Operation. For Turbine best efficiency we have restricted this 10°C value.
      Thanks

  • @AMITKUMAR-nz7wb
    @AMITKUMAR-nz7wb 4 роки тому

    Dear Sir please tell me why we maintain the hotwell level is 50 % and external cold water source of condenser during the process (for condensing purpose )

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +1

      If hotwell level maintain high it means this water tends to occupy the area where steam condensation which causes drop in vacuum, if water 20% or below the amount of water at pump suction side reduces which is reason of cavitation, and external cooling system is required for condensing the exhaust steam.

  • @harekrushnaacharya7862
    @harekrushnaacharya7862 4 роки тому +2

    Sir dummy karna matlab kya hai..plz explain ?? If possible with a picture of dummy

  • @sagargupta2090
    @sagargupta2090 3 роки тому

    how many passes in tube and shell of surface condenser install with turbine?

  • @arunchoudhary8179
    @arunchoudhary8179 4 роки тому +2

    10 degree hi q maintain kr t h sir

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Ye parameter volume of steam occupied in surface condenser and we rejecting only Latent heat so if we increase temperature it means Condenser volume is smaller in size so volume for exhaust steam is less to avoid this we maintain always temperature difference 10°C maximum.

  • @DheerajKumar-be5kj
    @DheerajKumar-be5kj 4 роки тому

    Water circulation kaise hota h sir cfbc boiler mei plz help me sir.....eco ,riser drum downcomer,evap downcomer, screen downcomer,....yeh sb mei kaha se water or kaise flow krta h plz help me sir

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому

      Please watch my video on CFBC Boiler this video helps you lots to understand this all point, for more details I'll make seperate video on this topic.

  • @sachinsahu504
    @sachinsahu504 4 роки тому +2

    Sir, what bad effect will occur if hot well level rise or down.

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +2

      Dear if hotwell level high it means the space in condenser is reduced for condensing the exhaust steam, so accumulation of non condensing gas increases it means vacuum drops, in second condition if hotwell level low it means shortage of water at suction of CEP Pump which is Reason of cavitation in pump, ultimately damage of pump so to avoide this type of happening always we maintain hotwell level.
      Thanks

    • @sumitkatkar2019
      @sumitkatkar2019 3 роки тому

      In between surface condenser and vapour condensate tank their is baromatric leg to maintain the vacuum inside the surface condenser so if it not maintained properly then vacuum breakdown will occur also vapour condensate pump will run dry. Also we have to maintain oxygen content of condensate because it will cause corrosion, for more information please refer HEI standard for steam surface condenser where they have mentioned 7ppb to 14 ppb oxygen content.

  • @siddaroodhapotaraddi4828
    @siddaroodhapotaraddi4828 2 роки тому

    What is Candensr safty sir

  • @alokkumarumrao5833
    @alokkumarumrao5833 4 роки тому +2

    Sir, surface condenser and condenser me difference kya h, plz detail me bataiye.

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  4 роки тому +1

      Condenser ek closed type of heat exchanger Device h jaha heat Ka exchange krte h, condenser may be classified according to their use like ACC where air is used for heat exchange & Surface Condenser where water is used for heat exchanging.

    • @alokkumarumrao5833
      @alokkumarumrao5833 4 роки тому +1

      @@PowerPlantDiscussion thanks

    • @uniqueworldpk5936
      @uniqueworldpk5936 4 роки тому

      @@PowerPlantDiscussion condenser type Detial btay plz

  • @lokeshlaxkar2671
    @lokeshlaxkar2671 3 роки тому

    Sir why temp difference between inlet water of condenser and outlet water maintained 10 ℃

  • @aanmolhota6394
    @aanmolhota6394 2 роки тому

    Which material is used to make surface condenser's tube?

  • @dabhiravi4305
    @dabhiravi4305 2 роки тому

    Sir condenser and ejector plant me uper kyu rakha jata he

  • @chitaranjanpradhan8222
    @chitaranjanpradhan8222 3 роки тому +2

    Sir isco counter surface condenced bolte he ki nehi

    • @PowerPlantDiscussion
      @PowerPlantDiscussion  3 роки тому

      Ye counter (means opposite) ni hota h balki cross flow bol skte h.

  • @dabhiravi4305
    @dabhiravi4305 2 роки тому

    Condenser and ejector uper kyu rakha jata he