Jacuzzi Hot Tub FL-1 Error code | Jacuzzi or Sundance Spas FL-1 Error Code

Поділитися
Вставка
  • Опубліковано 8 вер 2024

КОМЕНТАРІ • 24

  • @VIPPoolsandSpas
    @VIPPoolsandSpas  Рік тому +2

    We are getting very busy with UA-cam and our video comments. At the same time we are trying to run a pool and hot tub business. Unfortunately, we will limit our comment responses to our Members. Consider becoming a Member: ua-cam.com/channels/7rBDbZ5XT4QtOouN6PTKXQ.htmljoin

  • @brianbanks3044
    @brianbanks3044 Рік тому +1

    great tips....did the screwdiver test and code went off....after taking wires off and following back to Flow switch, I found the wires had corroded right off the top of the switch...there was a clear plastic cover over the wires and top of switch that prevented me from seeing the corroded ends....obviously, I found the problem...SCREWDRIVER TIP WAS THE TRICK THOUGH...thanks...PS, I have the J-325 model 2014

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Great. Make sure to give the video a like. Thanks for watching my video.

  • @raycheselka1
    @raycheselka1 Рік тому +1

    Hi! Thank you so much for this helpful video. I'm working through all of these and have a quick question. In step 3-you say to unplug the flow switch, turn the power on. Then you say the next test will be live-put the screw driver in, but then it says to turn the breaker on again. But it's supposed to already be on? If you wouldn't mind clarifying I'd greatly appreciate it!!!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Thanks for seeing that. Made changes to the video. Thanks again.

  • @virginieericdf5858
    @virginieericdf5858 Місяць тому +1

    hello, I am in France and owner of a j335 jacuzzi from 2015. I have an FL1 code. the massage pumps work but the circulation pump does not. the fuses are ok. Should the circulation pump be replaced? thanking you for your help.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Місяць тому +2

      FL1 code is there because the circ. pump isnt working. If the fuse is good, then you could test the volts where the circ pump plugs to the circuit board or just replace that circ pump.

    • @virginieericdf5858
      @virginieericdf5858 Місяць тому +1

      @@VIPPoolsandSpas Thank you so much!!! 🙏👍

  • @izapp
    @izapp 4 місяці тому +1

    ... with the unit flashing "FL 1", should there be voltage to the pumps? i presume there would, at least to the low speed pump. that being the case, if there is NOT voltage to either the low or high flow pump, then would it suggest that the control board needs replaced? (also, note that if this logic is correct, then it's potentially dangerous to short the flow switch for extended periods, because if there really is no flow then the heater would turn on without flow and overheat)

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  4 місяці тому

      Flow switch or pressure switch are low voltage and have no amps. It's the amps the kill ya. That's why cows don't get killed by an electric fence. As for testing the pump. If you're not confident call a professional.

  • @thomaspetito6923
    @thomaspetito6923 2 місяці тому +1

    Would this also cause my heater to intermittently kick on/off? I have this FL1 error but also my tub will not get up to temp

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 місяці тому

      Yep. Any FL code will at some point shut the heat off. If it's on/off sort of thing happening, this is telling me it's going to be the filters or flow switch/pressure switch (whatever one you might have.)

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 місяці тому

      If you unplug the switch, does FL2 come on?

    • @thomaspetito6923
      @thomaspetito6923 2 місяці тому +1

      @@VIPPoolsandSpas sorry didn’t see this but it was a bad flow switch

  • @deansiebert6237
    @deansiebert6237 3 місяці тому +1

    Does the Jacuzzi need to be drained on order to replace the flow switch? Thx

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 місяці тому +1

      No. We do have a video on just that question.

  • @brysonplayz3612
    @brysonplayz3612 5 місяців тому +1

    Do I need to close any valves when changing flow switch? Will water fly out on me? I just refilled with new water. Uggg

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  5 місяців тому +1

      NO. I do have a video on how to change it with the water in. Thats if it is a flow switch.

  • @lisasnyder5964
    @lisasnyder5964 4 місяці тому +1

    I had a hot tub installed and then had fl1 error code. The electrician had accidentally left 1 side of the wiring unhooked so only had 115v at the tub.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  4 місяці тому

      That would do it. Pump wasn't working. Lack of volts

  • @thatguysinger
    @thatguysinger Рік тому +1

    does hot tub need to be drained to replace flow switch? thanks!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      I always drain below the sensor to replace.

    • @thatguysinger
      @thatguysinger Рік тому +1

      @@VIPPoolsandSpas thanks!! love your videos!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      @@thatguysinger Thank you. Hit the LIKE on even the bad videos. lol