CAESAR-2 FLANGE LEAKAGE CHECK

Поділитися
Вставка
  • Опубліковано 11 вер 2024
  • HOW TO CHECK THE FLANGE LEAKAGE IN CAESAR-II
    For technical queries, Training & Project Detailed Engineering services, Please contact +91 9941404342
    Mail id: balmech28@gmail.com

КОМЕНТАРІ • 43

  • @BALAJIpiping
    @BALAJIpiping  6 місяців тому

    In this video i have calculated Bolt area for your understanding.
    Please refer ASME B1.1 to get the Bolt area directly based on the thread.

  • @Thejasngowda94
    @Thejasngowda94 6 місяців тому +1

    Excellent information 👍

  • @shanikumarsoni7202
    @shanikumarsoni7202 7 років тому

    Excellent sir! as I m beginner this video is very very useful for me now m waiting for your next video so plz upload as soon as possible ..thank you so much.

  • @deepaila1111
    @deepaila1111 Рік тому

    Hi,
    In NC method SYC yield strength and sy1 to sy9 values are comes differently

    • @BALAJIpiping
      @BALAJIpiping  6 місяців тому

      Yes, actually we need to consider Yield strength values based on the temperature..
      I have considered the same values..

  • @idleandactive
    @idleandactive 2 роки тому

    Hi Sir, thanks for knowledge sharing.can we have more videos please?

  • @vijaygupta-gc5on
    @vijaygupta-gc5on 4 роки тому

    so what is the allowable % ratio for flange leak check. Moreover, the input of yield strength relates to yield strength of bolt or flange material. I think it must be bolt material.

  • @bunc11
    @bunc11 6 років тому

    B16.5 2013 - class 900 - diameter of bolt circle 616 mm, not 434? where did u get that number?

    • @BALAJIpiping
      @BALAJIpiping  5 років тому

      Dear Mr.bunc11, Thanks for your valid point. As per ASME B 16.5 For 16", 900# BCD is 616 mm only.

  • @iamnotlanzbg5197
    @iamnotlanzbg5197 3 роки тому

    Stress safety factor should me more than 1 (Allowed/actual) then it is passed in equivalent pressure method ?

    • @BALAJIpiping
      @BALAJIpiping  3 роки тому

      Generally 1.5 times of Rated Pressure will be considered as Allowable in PEQ method

  • @ajithaju1513
    @ajithaju1513 9 місяців тому

    Thank 🙏🙏❤

  • @bagindamuazbagindabakhtiar7912
    @bagindamuazbagindabakhtiar7912 4 роки тому

    hi after i run it, the allowable pressure/stress column only show zeroes value. What step did i miss?

    • @BALAJIpiping
      @BALAJIpiping  4 роки тому

      Please share your mail id. You need to enter the flange analysis temperatures in Load case editor

    • @bagindamuazbagindabakhtiar7912
      @bagindamuazbagindabakhtiar7912 4 роки тому

      @@BALAJIpiping bagindamuaz@gmail.com. Thanks in advance!

  • @mat3851
    @mat3851 4 роки тому

    NC flange leakage is not applicable for all process piping. Therefore, calculations are not applicable in most cases.

    • @BALAJIpiping
      @BALAJIpiping  3 роки тому

      Flange leakage check is applicable for all type of flanges based on the criteria provided in the Stress specification. First we will check the flange leakage using Equivalent Pressure method. If it fails in PEQ method, we will go for NC 3658.3 or ASME Section VIII detailed method

  • @tdnd5452
    @tdnd5452 4 роки тому

    My flanges' allowable stresses still equalize to 0. How can I overcome to this? Thank you

    • @danlinengineers9282
      @danlinengineers9282 3 роки тому

      Hi Talla Diack, To check the Yield strength of material, we have to refer ASME BPVC Sec II Part D Table Y1. If u want more details. we discuss in detailed ..
      my mail id
      engineers@danlin.in
      whatsapp @+91 8800604940

    • @BALAJIpiping
      @BALAJIpiping  6 місяців тому +1

      please switch on the flange analysis temperature in the load case editor

  • @rendiyusuf5147
    @rendiyusuf5147 5 років тому

    How to get the bolt area calculated ?

    • @BALAJIpiping
      @BALAJIpiping  4 роки тому

      We are using area of circle formula to calculate the bolt area of 1 bolt and to be multiplied by total no. of bolts to get the total area.
      In this video i have calculated Bolt area for your understanding.
      Please refer ASME B1.1 to get the Bolt area directly based on the thread.

  • @mat3851
    @mat3851 4 роки тому

    What method is appliable for RTJ flanges?

    • @BALAJIpiping
      @BALAJIpiping  3 роки тому

      Flange leakage check is applicable for all type of flanges based on the criteria provided in the Stress specification.
      You can check the detailed flange leakage method (ASME Section VIII Flange Leakage Checking Method available in Caesar ii)

  • @KNITISH1996
    @KNITISH1996 2 роки тому

    Sir, can you Please provide video on flange leackage check by ASME sec VIII method?

    • @BALAJIpiping
      @BALAJIpiping  2 роки тому +1

      Yes sure.. Will try to add the video shortly..

    • @KNITISH1996
      @KNITISH1996 2 роки тому

      @@BALAJIpiping I am waiting impatiently.

    • @BALAJIpiping
      @BALAJIpiping  6 місяців тому

      Sorry, due to other projects I couldn't do the video.. Will try to upload ASAP.

  • @rays2.052
    @rays2.052 3 роки тому

    What is the different between NC-3658.3 and Peq?

    • @jassimidan926
      @jassimidan926 Рік тому

      NC-3658.3 its for the nuclar piping and the peq is asme b16.5

    • @BALAJIpiping
      @BALAJIpiping  6 місяців тому

      Flange with High Strength Bolting:
      For flanges with bolting material having allowable stress at 38°C not less than 138
      MPa shall be checked as per ASME Sec. Ill Division 1- Subsection NC, Clause NC-
      3658.3.
      Mrs~ 3125 (Sy/ 36000) CAb
      Mrd ~ 6250 (Syl 36000) C Ab
      Where
      Mrs = bending or torsion moment (considered separately) applied to the joint due to
      weight, thermal expansion of piping, sustained anchor movements, relief valve steady state thrust and other sustained mechanical loads applied to the flange joint during the design or service condition, (in.-lb).
      Mrd = bending or torsion moment (considered separately) as defined for Mrs but including dynamic loadings applied to the flanged joint during the design or service condition, (in.-lb).
      C = bolt circle diameter, (in).
      Sy = yield strength of flange material at Design Temperature, (psi).
      Ab = total cross-sectional area of bolts at root of thread or section of least diameter under stress, (in2).
      The value of Syl 36000 shall not be taken as greater than unity.

    • @BALAJIpiping
      @BALAJIpiping  6 місяців тому

      Flange not covered in the above category, leakage check shall be carried out based
      on Equivalent Pressure method as per ASME SEC Ill Division1-Subsection NC, Clause
      No. NC-3658.1 (a) Et (b) as mentioned below.
      Tightness of flanged joints is acceptable if:
      System Design Pressure + Pe q