Day in my life as a plumber 54. Vaillant Flue issues. Rusty Flues.

Поділитися
Вставка
  • Опубліковано 19 сер 2021
  • Quick video. Customer decided that she wanted a new boiler. Having quoted to replace, on attendance we found what you will see. Although the boiler was functioning I knew there had been lots of issues. New filling loop spotted, new spiro filter, multiple leaks and case internal perished. Ordinarily I would have repaired but with no warranty the benefits are clear for her. 10 year warranty. And a local service company to deal with.

КОМЕНТАРІ • 41

  • @davidceredig-evans8772
    @davidceredig-evans8772 3 роки тому +1

    Good to see you back.

    • @drpipe
      @drpipe  3 роки тому +1

      Was here last week 😂🤣😂

  • @chrisnixon5848
    @chrisnixon5848 2 роки тому +2

    Just bought myself the milwaukee compressor, good bit of kit. It amazes me when I go to do a boiler service and the amount of customers that say, well the last engineer didn't do all this and that, crazy to think people are working on a gas appliance and the risks they are willing to take to get the job done quick. Anyway Doc, your slowing down on the video's, what's going on? Appreciate its crazy busy for everyone at the moment. No idea why I even want to watch videos on plumbing when I do it myself lol 🤷‍♂️🤣🤣

    • @drpipe
      @drpipe  2 роки тому +1

      See what I can do 😎😎

  • @chrisnixon5848
    @chrisnixon5848 2 роки тому +1

    Cheers Doc, another good video. Beggers belief, so easy to chamfer the pipe and yet people can't be bothered 🤦‍♂️🤦‍♂️

    • @drpipe
      @drpipe  2 роки тому

      Cheers bud

  • @jasoncheetham3875
    @jasoncheetham3875 3 роки тому +2

    Hey mate
    Great video again 👍
    The contract I work on we have lots of vaillant boilers , your right about the installers accidentally drilling into the plastic flue it has caused lots of issues !!
    Also the packing washer in the flue turret fails quite often , giving readings on the air intake 👍
    First comment and might help others 😎

    • @drpipe
      @drpipe  3 роки тому

      Thanks buddy. “ Packing washer” you mean the sponge type one on the turret or the flue seal on the hex to turret ? 🙏 the hex one is going bcos of Hi temps set 💯

    • @jasoncheetham3875
      @jasoncheetham3875 3 роки тому

      @@drpipe yes mate the one that the flue sits into
      Part no 981227
      It might help engineers who possibly think a flue seal has gone but in fact it’s just the packing ring
      As I say hope this helps 👍

    • @drpipe
      @drpipe  3 роки тому +1

      If that goes it’s only sucking fresh air in would effect Co but def not Room sealed no more 🙏

  • @liveloud9894
    @liveloud9894 2 роки тому +2

    We have loads of pro 28s on our contract and the issue with the failed packing ring seal is very common, we have our engineers check the air intake readings on every one now especially longer flues

    • @plumbertime
      @plumbertime 2 роки тому +1

      Should be done on every boiler where you can anyway

  • @colinfleming1828
    @colinfleming1828 2 роки тому +1

    We have a lot pros etc in our area aswell suppose it's just cause that many . Never changed so many heat exchangers flue seals diverted valves pressure sensors PC in ma life.wb seals fit the inner on them.

    • @drpipe
      @drpipe  2 роки тому

      And AAV 🤣

  • @stuarthughes808
    @stuarthughes808 3 роки тому +1

    Christ on a bike. That’s some boxing in for the flue. How do you inspect the joints. Is it open at the top. Great vid dr p

    • @drpipe
      @drpipe  3 роки тому +1

      No lid on it mate 💯👍🙏🙏 just one in one out .

  • @onewheelnut
    @onewheelnut 2 роки тому

    Great video and you are right in all that you say but there's no way that flue had s 3-4 Deg fall.

  • @Tony-sr7vq
    @Tony-sr7vq 2 роки тому +1

    Love your videos but have you put more on the last one is 3 months old

  • @jackbell3601
    @jackbell3601 3 роки тому +1

    Dr pipe it’s when the boss says yeah just put the New boiler in and reuse the existing flue 😂😆🙄 BTW have you got a link for somewhere to order those flue screws you use? Cheers for the video mate!

    • @drpipe
      @drpipe  2 роки тому +1

      Toolstation.....Drywall Phillips Screw Wafer Head Self Drill 4.2 x 12mm

  • @SuperWayneyb
    @SuperWayneyb 3 роки тому +1

    🤘😎🤘

  • @stephenpyrek4726
    @stephenpyrek4726 2 роки тому +1

    U well DOC not had anything for a while

    • @drpipe
      @drpipe  2 роки тому

      I am mate thanks for asking 🙏🙏☝️ busy and finding the grind a bit challenging.. hopefully Xmas special 🙏

    • @stephenpyrek4726
      @stephenpyrek4726 2 роки тому

      @@drpipe absolutely crazy few
      Months and it doesn’t seem to b wanting to let up, stay safe n hopefully see u with ur xmas jumper on

  • @rayc1503
    @rayc1503 3 роки тому +1

    The audio was particularly bad on most of this one Doc pipe. With the visual I got the jist of it. Maybe a try doing a voiceover whilst editing on the next one. Thanks for sharing 👍.

    • @drpipe
      @drpipe  3 роки тому +1

      Just had a listen sounds Great to me.. try turning up your Hearing Aid 😂🤣 Only joking mate.. no time for voice overs .. 🙏👍

    • @macpatel7810
      @macpatel7810 3 роки тому +1

      Sounds good to me too.. sorry Ray.

    • @rayc1503
      @rayc1503 3 роки тому

      @@macpatel7810 In that case maybe I do need to get my hearing checked then 🙉🤣. Probably too much core drilling without ear guards.

    • @macpatel7810
      @macpatel7810 3 роки тому

      @@rayc1503 I hear you bro. 🙄😄